Characterising core body temperature response of free‐moving C57BL/6 mice to 1.95 GHz whole‐body radiofrequency‐electromagnetic fields
Bioelectromagnetics · 2024-12 · 45 (8) · 387-398
DOI: 10.1002/bem.22527 ↗At a glance
Journal article in Bioelectromagnetics, published online on 2024-10-14. Written by Emma Sylvester and 6 co-authors. Institution: School of Medical, Indigenous and Health Sciences, Molecular Horizons, University of Wollongong, Wollongong, Australia. Major MEDLINE topics: Mice, Inbred C57BL, Radio Waves, Body Temperature. Cited 5 times so far (Crossref); 28 references. The full text is freely available (open access, CC BY 4.0). Funded by: National Health and Medical Research Council.
Abstract (original language)
The present study investigated the core body temperature (CBT) response of free‐moving adult male and female C57BL/6 mice, during and following a 2‐h exposure to 1.95 GHz RF‐EMF within custom‐built reverberation chambers, using temperature capsules implanted within the intraperitoneal cavity and data continuously logged and transmitted via radiotelemetry postexposure. Comparing RF‐EMF exposures (WBA‐SAR of 1.25, 2.5, 3.75, and 5 W/kg) to the sham‐exposed condition, we identified a peak in CBT within the first 16 min of RF‐EMF exposure (+0.15, +0.31, +0.24, +0.37°C at 1.25, 2.5, 3.75, and 5 W/kg respectively; statistically significant at WBA‐SAR ≥ 2.5 W/kg only), which largely dissipated for the remainder of the exposure period. Immediately before the end of exposure, only the CBT of the 5 W/kg condition was statistically differentiable from sham. Based on our findings, it is apparent that mice are able to effectively compensate for the increased thermal load at RF‐EMF strengths up to 5 W/kg. In addition, the elevated CBT at the end of the exposure period in the 5 W/kg condition was statistically significantly reduced compared to the sham condition immediately after RF‐EMF exposure ceased. This would indicate that measures of CBT following the end of an RF‐EMF exposure period may not reflect the actual change in the CBT of mice caused by RF‐EMF exposure in mice.
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- School of Medical, Indigenous and Health Sciences, Molecular Horizons, University of Wollongong, Wollongong, Australia.
- Wollongong Bioelectromagnetics Laboratory, Wollongong, Australia.
- 6G Research and Innovation Lab, Swinburne University of Technology, Hawthorn, Australia.
- Telstra Limited, Melbourne, Australia.
- School of Psychology, University of Wollongong, Wollongong, Australia.
- Australian Centre for Electromagnetic Bioeffects Research, Wollongong, New South Wales, Australia.
Funding
- National Health and Medical Research Council
Cite
APA
Sylvester, E., Deng, C., McIntosh, R., Iskra, S., Frankland, J., McKenzie, R., & Croft, R. J. (2024). Characterising core body temperature response of free‐moving C57BL/6 mice to 1.95 GHz whole‐body radiofrequency‐electromagnetic fields. Bioelectromagnetics, 45(8), 387-398. https://doi.org/10.1002/bem.22527
Vancouver
Sylvester E, Deng C, McIntosh R, Iskra S, Frankland J, McKenzie R, et al. Characterising core body temperature response of free‐moving C57BL/6 mice to 1.95 GHz whole‐body radiofrequency‐electromagnetic fields. Bioelectromagnetics. 2024;45(8):387-398. doi:10.1002/bem.22527
BibTeX
@article{Sylvester2024,
author = {Sylvester, Emma and Deng, Chao and McIntosh, Robert and Iskra, Steve and Frankland, John and McKenzie, Raymond and Croft, Rodney J},
title = {Characterising core body temperature response of free‐moving C57BL/6 mice to 1.95 GHz whole‐body radiofrequency‐electromagnetic fields},
journal = {Bioelectromagnetics},
year = {2024},
volume = {45},
number = {8},
pages = {387--398},
doi = {10.1002/bem.22527}
}
EUVIMED