EUVIMEDEUVIMED entdecken
Crossref

Heavily Labeled Signal Probe for Electrogenerated Chemiluminescence Peptide‐Based Biosensing of Matrix Metalloproteinase 2

Danyang Zhang, Manping Qian, Xiaolin Yang, Chengxiao Zhang, Honglan Qi iD

Chemistry – An Asian Journal · 2024

DOI: 10.1002/asia.202400743 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Chemistry – An Asian Journal, 2024. Verfasst von Danyang Zhang und 4 weiteren Autor:innen. Beteiligte Einrichtung: Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province, School of Chemistry and Chemical Engineering, Shaanxi Normal University,…. Hauptthemen laut MEDLINE: Matrix Metalloproteinase 2, Biosensing Techniques, Peptides, Luminescent Measurements. Die Arbeit nennt 24 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Fundamental Research Funds for the Central Universities.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The field of electrogenerated chemiluminescence (ECL) biosensing has witnessed remarkable growth, emphasizing the need for precise detection of biomarkers. The synthesis approach of peptide‐based signal probe with high recognition ability and high ECL efficiency is a significant issue in the ECL biosensing. Here, a heavily labeled signal probe was synthesized for ECL peptide‐based biosensing tactic by using a new aldehyde bearing cyclometalated Ir(III) complex ([Ir(bt) 2 (bpy‐CHO)PF 6 (bt=2‐phenylbenzothiazole, bpy‐CHO=4’‐methyl‐[2,2’‐bipyridine]‐4‐carbaldehyde, denoted as Ir1) as ECL signal reagent and streptavidin (SA) as carrier protein. One ECL peptide‐based biosensing method was exemplified for the detection of matrix metalloproteinase 2 (MMP‐2) by using Ir1 labeled SA (SA−Ir1) as heavily labeled signal probe and biotinylated peptide as molecular recognition substrate. MMP‐2 was sensitively detected in the range from 5 to 100 ng/mL with a detection limit of 1.5 ng/mL. Importantly, two detection modes differing in the order of cleavage recognition by MMP‐2 and signal transduction with SA−Ir1 were compared for the first time. First cleavage and second signal transduction were proposed to be beneficial to sensitive detection of target, which provides some ideas for biomarker diagnostics in disease screening at an early stage.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Matrix Metalloproteinase 2Biosensing TechniquesPeptidesLuminescent MeasurementsHumansIridiumCoordination ComplexesLuminescenceElectrochemical TechniquesLimit of DetectionStreptavidin

Stichwörter der Autor:innen

Cyclometalated iridium(III) complexECL biosensingMMP-2PeptideStreptavidin

Substanzen

Matrix Metalloproteinase 2PeptidesIridiumCoordination ComplexesStreptavidin

Autor:innen und Institutionen

  • Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province, School of Chemistry and Chemical Engineering, Shaanxi Normal University, Xi' an, 710119, P. R. China.

ORCID-Profile: Honglan Qi

Förderung

  • National Natural Science Foundation of China
  • Fundamental Research Funds for the Central Universities

Zitieren

APA

Zhang, D., Qian, M., Yang, X., Zhang, C., & Qi, H. (2024). Heavily Labeled Signal Probe for Electrogenerated Chemiluminescence Peptide‐Based Biosensing of Matrix Metalloproteinase 2. Chemistry – An Asian Journal. https://doi.org/10.1002/asia.202400743

Vancouver

Zhang D, Qian M, Yang X, Zhang C, Qi H. Heavily Labeled Signal Probe for Electrogenerated Chemiluminescence Peptide‐Based Biosensing of Matrix Metalloproteinase 2. Chemistry – An Asian Journal. 2024. doi:10.1002/asia.202400743

BibTeX
@article{Zhang2024,
  author = {Zhang, Danyang and Qian, Manping and Yang, Xiaolin and Zhang, Chengxiao and Qi, Honglan},
  title = {Heavily Labeled Signal Probe for Electrogenerated Chemiluminescence Peptide‐Based Biosensing of Matrix Metalloproteinase 2},
  journal = {Chemistry – An Asian Journal},
  year = {2024},
  doi = {10.1002/asia.202400743}
}
Kostenlos starten →