EUVIMEDEUVIMED entdecken
Vergleichsstudie

A comprehensive guide to high‐fidelity 3D neuroanatomical modeling techniques: A quantitative comparison between photogrammetry and structured light scanning

Megan M J Bauman iD, Amedeo Piazza, Fabio Torregrossa, Charles Wes Price, Jonathan M Morris, Luciano C P C Leonel, Maria Peris-Celda

Anatomical Sciences Education · 2025

DOI: 10.1002/ase.70062 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Anatomical Sciences Education, 2025. Verfasst von Megan M J Bauman und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Neurosurgery, Mayo Clinic, Rochester, Minnesota, USA. Hauptthemen laut MEDLINE: Photogrammetry, Imaging, Three-Dimensional, Models, Anatomic, Neuroanatomy. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 38 Literaturangaben. Gefördert von: Joseph I. and Barbara Ashkins Endowed Professorship in Neurosurgery, Charles B. and Ann L. Johnson Endowed Professorship in Neurosurgery.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Cadaveric dissections, which are considered the most realistic model to study neuroanatomy, are expensive and not readily available in all centers. Given the surge of technological advances, incorporation of three‐dimensional (3D) scanning technologies and 3D models has gained popularity, both in the educational and clinical settings. We present our institutional experience in creating high‐fidelity neuroanatomical 3D models using three 3D scanning techniques: structured light 3D scanning, “manual” photogrammetry with a single DSLR camera, and “automatic” photogrammetry using a scanner equipped with five vertically arranged DSLR cameras and an automatic turntable within a square box. A survey study was conducted with 20 neurosurgical residents to assess the quality of the three resulting 3D models. In the study, “manual” photogrammetry was determined to be the most cost‐effective technique, while “automatic” photogrammetry was the most time‐effective and user‐friendly technique. The best visual quality was obtained using “manual” photogrammetry, as determined from survey results of 20 neurosurgical residents. While structured light 3D scanning had the lowest quality of resolution of the texture map, this technique was the most accurate to use for determining measurements, with a fixed accuracy of 0.05 mm. Overall, “manual” photogrammetry can allow for the most detailed 3D models and is the most cost‐effective strategy, while structured light 3D scanning is most suitable for obtaining clinically relevant measurements given the high degree of structural accuracy. Alternatively, “automatic” photogrammetry can serve as a hybrid between obtaining relatively high‐quality models in a time‐effective and user‐friendly manner.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

PhotogrammetryImaging, Three-DimensionalModels, AnatomicNeuroanatomyHumansInternship and ResidencyCadaverDissection

Stichwörter der Autor:innen

3D modelsneuroanatomical educationneuroanatomyphotogrammetrystructured light 3D scanning

Autor:innen und Institutionen

  • Department of Neurosurgery, Mayo Clinic, Rochester, Minnesota, USA.
  • Mayo Clinic Rhoton Neurosurgery and Otolaryngology Surgical Anatomy Program, Rochester, Minnesota, USA.
  • Department of Neuroscience, "Sapienza" University, Rome, Italy.
  • Neurosurgical Unit, Department of Biomedicine, Neurosciences and Advanced Diagnostics (BiND), University of Palermo, Palermo, Italy.
  • Division of Biomedical and Scientific Visualization, Mayo Clinic, Rochester, Minnesota, USA.
  • Department of Radiology, Mayo Clinic, Rochester, Minnesota, USA.

ORCID-Profile: Megan M J Bauman

Förderung

  • Joseph I. and Barbara Ashkins Endowed Professorship in Neurosurgery
  • Charles B. and Ann L. Johnson Endowed Professorship in Neurosurgery

Zitieren

APA

Bauman, M. M. J., Piazza, A., Torregrossa, F., Price, C. W., Morris, J. M., Leonel, L. C. P. C., & Peris-Celda, M. (2025). A comprehensive guide to high‐fidelity 3D neuroanatomical modeling techniques: A quantitative comparison between photogrammetry and structured light scanning. Anatomical Sciences Education. https://doi.org/10.1002/ase.70062

Vancouver

Bauman MMJ, Piazza A, Torregrossa F, Price CW, Morris JM, Leonel LCPC, et al. A comprehensive guide to high‐fidelity 3D neuroanatomical modeling techniques: A quantitative comparison between photogrammetry and structured light scanning. Anatomical Sciences Education. 2025. doi:10.1002/ase.70062

BibTeX
@article{Bauman2025,
  author = {Bauman, Megan M J and Piazza, Amedeo and Torregrossa, Fabio and Price, Charles Wes and Morris, Jonathan M and Leonel, Luciano C P C and Peris-Celda, Maria},
  title = {A comprehensive guide to high‐fidelity 3D neuroanatomical modeling techniques: A quantitative comparison between photogrammetry and structured light scanning},
  journal = {Anatomical Sciences Education},
  year = {2025},
  doi = {10.1002/ase.70062}
}
Kostenlos starten →