EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Inception of vented water trees in high voltage XLPE cable insulation: Effect of inorganic contaminations inside the semiconductive material

Sofie B. Hårberg, Sigurd Wenner, Sverre Hvidsten, Mari‐Ann Einarsrud

Journal of Applied Polymer Science · 15.11.2024 · 141 (43)

DOI: 10.1002/app.56136 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Applied Polymer Science, online erschienen am 17.08.2024. Verfasst von Sofie B. Hårberg und 3 weiteren Autor:innen. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Norges Forskningsråd.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Wet‐design AC subsea power cables are currently rated up to a maximum voltage of 72.5 kV. These high voltage (HV) cables are cost‐effective alternatives to subsea cables kept dry by a protective lead sheath and exhibit superior properties for dynamic applications. However, several vented water trees, degradation phenomena reducing the cable lifetime, are observed in a HV XLPE insulated cable subjected to wet aging in the laboratory. The water trees initiate from a smooth and clean XLPE insulation/semiconductive screen interface. In this paper, we show that voids in the range 15–150 μm are observed in the conductor screen, 50–320 μm from the water tree inception sites. Degradation of the semiconductive material is observed, in the form of porous regions that connect the voids to the water tree inception sites. NaCl impurities are detected on the void surfaces and in the porous regions. These features are proposed to be the pre‐requisites for the formation of the vented water trees observed in this type of cable. The mechanism responsible for the formation of the void and porous regions in the semiconductive cable screen is discussed based on the observations.

Förderung

  • Norges Forskningsråd

Zitieren

APA

Hårberg, S. B., Wenner, S., Hvidsten, S., & Einarsrud, M. (2024). Inception of vented water trees in high voltage XLPE cable insulation: Effect of inorganic contaminations inside the semiconductive material. Journal of Applied Polymer Science, 141(43). https://doi.org/10.1002/app.56136

Vancouver

Hårberg SB, Wenner S, Hvidsten S, Einarsrud M. Inception of vented water trees in high voltage XLPE cable insulation: Effect of inorganic contaminations inside the semiconductive material. Journal of Applied Polymer Science. 2024;141(43). doi:10.1002/app.56136

BibTeX
@article{Hrberg2024,
  author = {Hårberg, Sofie B. and Wenner, Sigurd and Hvidsten, Sverre and Einarsrud, Mari‐Ann},
  title = {Inception of vented water trees in high voltage XLPE cable insulation: Effect of inorganic contaminations inside the semiconductive material},
  journal = {Journal of Applied Polymer Science},
  year = {2024},
  volume = {141},
  number = {43},
  doi = {10.1002/app.56136}
}
Kostenlos starten →