EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Detection of Perchlorate in Swabs Using Linear Sweep Voltammetry at a Liquid–Liquid Microinterface Array

Celine P. A. Otiob, Hum B. Lamichhane, Xiaoqing Lv, Lauren N. Gilson, Philip W. Bateman, Damien W. M. Arrigan

Analysis & Sensing · 2026-05 · 6 (3)

DOI: 10.1002/anse.202500149 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analysis & Sensing, online erschienen am 10.04.2026. Verfasst von Celine P. A. Otiob und 5 weiteren Autor:innen. Die Arbeit nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Perchlorate is a potential environmental contaminant and ease of its detection is needed to support environmental monitoring. Current detection methods mainly involve chromatographic and mass spectrometric methods, which have limitations in terms of portability and cost. This study explores the use of electrochemistry at the interface between two immiscible electrolyte solutions (ITIES) as an approach for perchlorate detection within sample swabs, e.g., from plant leaf surfaces in areas which may be contaminated with debris from frequent firework displays. Ion transfer voltammetry was employed to detect perchlorate based on its transfer across an array of micrometer‐scale ITIES (µITIES). Experiments to evaluate sensitivity and selectivity of the approach enabled detection of less than 1 μM of perchlorate; the presence of common additional ions, such as nitrate, hydrogen phosphate, and sulfate, did not impact the detection of perchlorate. A series of experiments in which perchlorate was intentionally introduced into samples, both on cotton swabs and on leaf surfaces that were subsequently swabbed, showed that cotton swabs could be used to sample perchlorate from environmental surfaces. Field sampling of leaf surface before and after firework displays indicates that ion transfer voltammetry at a µITIES array offers a viable approach to the detection of perchlorate in swabs and on swabbed surfaces.

Zitieren

APA

Otiob, C. P. A., Lamichhane, H. B., Lv, X., Gilson, L. N., Bateman, P. W., & Arrigan, D. W. M. (2026). Detection of Perchlorate in Swabs Using Linear Sweep Voltammetry at a Liquid–Liquid Microinterface Array. Analysis & Sensing, 6(3). https://doi.org/10.1002/anse.202500149

Vancouver

Otiob CPA, Lamichhane HB, Lv X, Gilson LN, Bateman PW, Arrigan DWM. Detection of Perchlorate in Swabs Using Linear Sweep Voltammetry at a Liquid–Liquid Microinterface Array. Analysis & Sensing. 2026;6(3). doi:10.1002/anse.202500149

BibTeX
@article{Otiob2026,
  author = {Otiob, Celine P. A. and Lamichhane, Hum B. and Lv, Xiaoqing and Gilson, Lauren N. and Bateman, Philip W. and Arrigan, Damien W. M.},
  title = {Detection of Perchlorate in Swabs Using Linear Sweep Voltammetry at a Liquid–Liquid Microinterface Array},
  journal = {Analysis & Sensing},
  year = {2026},
  volume = {6},
  number = {3},
  doi = {10.1002/anse.202500149}
}
Kostenlos starten →