Journal article in Analytical Science Advances, published online on 2026-05-15. Written by Poonam Verma and 1 co-authors. Institution: Radioanalytical Chemistry Division, Bhabha Atomic Research Centre Mumbai India. Cited 1 times so far (Crossref); 41 references. The full text is freely available (open access, CC BY-NC-ND 4.0).

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

A simple, robust and cost‐effective analytical methodology was developed for the determination of niobium in highly refractory materials: Nb‐doped gadolinium zirconate (Gd 2 Zr 2 O 7 :Nb) and niobium pentoxide (Nb 2 O 5 ). The challenge of digesting these matrices was successfully accomplished by establishing two independent dissolution procedures: (i) Fluoride‐free digestion under reflux conditions and (ii) microwave‐assisted digestion using a minimal volume of hydrofluoric acid (0.1 mL of 40% hydrofluoric acid). This dual digestion approach provides reliability, flexibility and robustness to the method. Subsequent to dissolution of highly refractory solid matrices, a one‐step spectrophotometric method for Nb determination based on the formation of peroxoniobium complex in sulfuric acid medium was optimised and developed. The proposed method is easy and straightforward, with fewer procedural steps and requires a lower chemical inventory. The developed method has a wide linear dynamic range of 2–225 ppm Nb spanning two orders of magnitude with a regression coefficient of 0.99945 and a detection limit of 0.4 ppm. The precision obtained is 2.13% (method relative standard deviation [RSD], n = 5) and 0.17% (instrumental RSD, n = 9). The recovery of Nb from spiked samples at a 50 ppm level is greater than 98% and, thereby validating the proposed method. Furthermore, the proposed method is independently authenticated using total reflection X‐ray fluorescence/energy‐dispersive X‐ray fluorescence techniques, with the results showing good agreement within the 95% confidence interval.

Subjects

Author keywords

Gd2Zr2O7Nb determinationfluoride‐free dissolutionrefractory material digestionspectrophotometry

Authors and institutions

  • Radioanalytical Chemistry Division, Bhabha Atomic Research Centre Mumbai India.
  • Radiation Technology Development Division, Bhabha Atomic Research Centre Mumbai India.

ORCID profiles: Poonam Verma

Cite

APA

Verma, P., & Chandane, A. (2026). A Robust Cost‐Effective Spectrophotometric Method for Nb Determination in Refractory Nb‐doped Gadolinium Zirconate: Overcoming Matrix Dissolution Challenges. Analytical Science Advances, 7(1). https://doi.org/10.1002/ansa.70089

Vancouver

Verma P, Chandane A. A Robust Cost‐Effective Spectrophotometric Method for Nb Determination in Refractory Nb‐doped Gadolinium Zirconate: Overcoming Matrix Dissolution Challenges. Analytical Science Advances. 2026;7(1). doi:10.1002/ansa.70089

BibTeX
@article{Verma2026,
  author = {Verma, Poonam and Chandane, Annapurna},
  title = {A Robust Cost‐Effective Spectrophotometric Method for Nb Determination in Refractory Nb‐doped Gadolinium Zirconate: Overcoming Matrix Dissolution Challenges},
  journal = {Analytical Science Advances},
  year = {2026},
  volume = {7},
  number = {1},
  doi = {10.1002/ansa.70089}
}
Start for free →