The Bell‐Bloom‐Type Optically‐Pumped FID Rubidium Atomic Magnetometer With a Multi‐Passing Probe Beam and Two Counter‐Propagating Pump Beams
Annalen der Physik · 2026-07 · 538 (7)
DOI: 10.1002/andp.70254 ↗Kurz gefasst
Fachartikel in der Zeitschrift Annalen der Physik, online erschienen am 21.07.2026. Verfasst von Yongbiao Yang und 6 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 38 Literaturangaben. Gefördert von: National Natural Science Foundation of China.
Abstract (Originalsprache)
The Bell‐Bloom‐type optically‐pumped atomic magnetometers are well‐suited for weak geomagnetic field detection. However, conventional single‐beam pumping introduces an atomic spin polarization gradient, which limits the measurement accuracy and sensitivity. To address this issue, this paper proposes and experimentally demonstrates a Bell‐Bloom‐type rubidium FID magnetometer scheme integrating orthogonally polarized counter‐propagating pumping and multi‐pass probe detection. This design homogenizes the atomic spin polarization distribution and suppresses light shifts and power broadening. This uniform polarization, in turn, allows the five‐pass probe configuration to achieve a significantly larger signal amplitude. Experimental results reveal that, compared with the traditional single‐beam pumping and single‐pass detection scheme, the proposed magnetometer achieves a remarkable improvement in magnetic field measurement accuracy, and the magnetic field sensitivity is improved from 18.9 to 3.1 pT/. Notably, the two techniques work synergistically, yielding a 6.1‐fold sensitivity enhancement that far exceeds their individual gains. This work provides an effective technical approach and reference for optimizing the performance of atomic magnetometers and their applications in precision measurement fields.
Förderung
- National Natural Science Foundation of China
Zitieren
APA
Yang, Y., Su, Z., Li, Y., Wang, Y., He, J., Jia, X., & Wang, J. (2026). The Bell‐Bloom‐Type Optically‐Pumped FID Rubidium Atomic Magnetometer With a Multi‐Passing Probe Beam and Two Counter‐Propagating Pump Beams. Annalen der Physik, 538(7). https://doi.org/10.1002/andp.70254
Vancouver
Yang Y, Su Z, Li Y, Wang Y, He J, Jia X, et al. The Bell‐Bloom‐Type Optically‐Pumped FID Rubidium Atomic Magnetometer With a Multi‐Passing Probe Beam and Two Counter‐Propagating Pump Beams. Annalen der Physik. 2026;538(7). doi:10.1002/andp.70254
BibTeX
@article{Yang2026,
author = {Yang, Yongbiao and Su, Zhengyu and Li, Yang and Wang, Yanhua and He, Jun and Jia, Xiaojun and Wang, Junmin},
title = {The Bell‐Bloom‐Type Optically‐Pumped FID Rubidium Atomic Magnetometer With a Multi‐Passing Probe Beam and Two Counter‐Propagating Pump Beams},
journal = {Annalen der Physik},
year = {2026},
volume = {538},
number = {7},
doi = {10.1002/andp.70254}
}
EUVIMED