Abstract (Originalsprache)

Background

The measurement of muscular activity in the face is a central component in the diagnosis of patients with facial nerve palsy. Magnetomyography (MMG) is a method for contactless measurement of magnetic muscle potentials. This study investigated whether non-invasive MMG using optically pumped magnetometers (OPM) is a feasible instrument for visualizing facial muscle activity.

Methods

An anatomically shaped mask with an assembly of eleven OPM was arranged to the right side of the face of five healthy subjects to measure MMG of facial muscles while repetitively performing twelve different standardized facial expressions. The root-mean-square (RMS) average of each facial expression-trial per OPM and individual subject was calculated, color-scaled, and mapped to the individual face per facial expression. In addition, the maximum average muscle activity and signal-to-noise ratio (SNR) per facial expression were investigated.

Results

Facial muscle activity could be mapped individually per facial expression, but the positioning of the OPM revealed to be a crucial factor for mapping accurately muscle activity. The SNR ranged from 1 to 8, the maximal observed average muscle activity reached almost 25pT in one subject and was on average 1±0.57pT.

Conclusions

Imaging specific facial activity via MMG with an array of OPM is possible, but precise sensor positioning is mandatory. In comparison to other skeletal muscles, the signal amplitude of facial muscles is low and the interindividual anatomical variability makes the setup challenging. As imaging of facial MMG is feasible, this study paves the way for future studies for using quantum sensors diagnostics, monitoring and rehabilitation of facial muscle and facial nerve disorders. Publication History Article published online: 19 April 2024 © 2024. Thieme. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany

Zitieren

APA

Fraunberg, J. V., Lu, H., Yang, H., Marquetand, N., Braun, C., Rüttiger, L., Wolpert, S., Knipper, M., Siegel, M., Löwenheim, H., & Marquetand, J. (2024). Facial magnetomyography using an array of optically pumped magnetometer. Laryngo-Rhino-Otologie, 103(S 02 S 02), S336-S337. https://doi.org/10.1055/s-0044-1785144

Vancouver

Fraunberg JV, Lu H, Yang H, Marquetand N, Braun C, Rüttiger L, et al. Facial magnetomyography using an array of optically pumped magnetometer. Laryngo-Rhino-Otologie. 2024;103(S 02 S 02):S336-S337. doi:10.1055/s-0044-1785144

BibTeX
@article{Fraunberg2024,
  author = {Fraunberg, Johannes von and Lu, Hongyu and Yang, Haodi and Marquetand, Nura and Braun, Christoph and Rüttiger, Lukas and Wolpert, Stephan and Knipper, Marlies and Siegel, Markus and Löwenheim, Hubert and Marquetand, Justus},
  title = {Facial magnetomyography using an array of optically pumped magnetometer},
  journal = {Laryngo-Rhino-Otologie},
  year = {2024},
  volume = {103},
  number = {S 02 S 02},
  pages = {S336--S337},
  doi = {10.1055/s-0044-1785144}
}
Kostenlos starten →