Optimization of SWCNT‐FET Biosensors by Aptamer Engineering and Toehold‐Mediated Strand Displacement
Advanced Science · 2026
DOI: 10.1002/advs.75328 ↗Kurz gefasst
Fachartikel in der Zeitschrift Advanced Science, 2026. Verfasst von Haosen Miao und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, Queen Mary University of London, London, UK. Hauptthemen laut MEDLINE: Biosensing Techniques, Nanotubes, Carbon, Aptamers, Nucleotide, Transistors, Electronic. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 78 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Research Foundation of Korea, Korea government, Institute of Information & Communications Technology Planning & Evaluation.
Abstract (Originalsprache)
Aptamer‐based single‐walled carbon nanotube (SWCNT) field‐effect transistor (FET) biosensors provide a compact, label‐free, and sensitive platform for real‐time biomarker detection. To enhance device performance, we employed a truncated DNA aptamer (CSS.3_cut3) with improved conformational switching upon cortisol binding, boosting the sensitivity of SWCNT‐FET biosensors. We further optimized the functionalization using a toehold‐mediated strand displacement (TMSD) strategy to dynamically integrate the aptamer onto SWCNTs in solution, simplifying the fabrication process and increasing the sensitivity. Interestingly, introducing a partially complementary protection strand during TMSD assembly resulted in bistable, two‐level signal outputs upon cortisol sensing, contrasting with the gradual response of unprotected sensors. This effect likely stems from the competition between aptamer–target binding and residual hybridization, modulating signal dynamics via tuneable electrostatic gating. These results underscore the promise of aptamer engineering and DNA nanotechnology for developing high‐performance biosensors with programmable behavior, offering new avenues for real‐time sensing, dynamic molecular recognition, and integrated diagnostic technologies.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Chemistry, Queen Mary University of London, London, UK.
- School of Chemical Engineering, University of New South Wales, Sydney, New South Wales, Australia.
- 711th Human Performance Wing, Air Force Research Laboratory, Ohio, USA.
- Department of Chemistry, Seoul Women's University, Seoul, Republic of Korea.
ORCID-Profile: Chang-Seuk Lee, Matteo Palma
Förderung
- National Research Foundation of Korea
- Korea government
- Institute of Information & Communications Technology Planning & Evaluation
- U.S. Air Force Office of Scientific Research
Zitieren
APA
Miao, H., Zheng, T., Yu, H., Manoharan, G., Sant'Anna, G., Bedfrod, N., Chávez, J. L., Lee, C. S., & Palma, M. (2026). Optimization of SWCNT‐FET Biosensors by Aptamer Engineering and Toehold‐Mediated Strand Displacement. Advanced Science. https://doi.org/10.1002/advs.75328
Vancouver
Miao H, Zheng T, Yu H, Manoharan G, Sant'Anna G, Bedfrod N, et al. Optimization of SWCNT‐FET Biosensors by Aptamer Engineering and Toehold‐Mediated Strand Displacement. Advanced Science. 2026. doi:10.1002/advs.75328
BibTeX
@article{Miao2026,
author = {Miao, Haosen and Zheng, Tingting and Yu, Houlin and Manoharan, Gririraj and Sant'Anna, Gustavo and Bedfrod, Nicholas and Chávez, Jorge L and Lee, Chang-Seuk and Palma, Matteo},
title = {Optimization of SWCNT‐FET Biosensors by Aptamer Engineering and Toehold‐Mediated Strand Displacement},
journal = {Advanced Science},
year = {2026},
doi = {10.1002/advs.75328}
}
EUVIMED