An All‐Soft Wearable Electrochemiluminescence Chip for Sweat Metabolite Detection
Advanced Science · 2026-02 · 13 (10)
DOI: 10.1002/advs.202519435 ↗Kurz gefasst
Fachartikel in der Zeitschrift Advanced Science, online erschienen am 04.01.2026. Verfasst von Wei Nie und 7 weiteren Autor:innen. Beteiligte Einrichtung: Key Laboratory of Precision and Intelligent Chemistry, Department of Chemistry, University of Science and Technology of China, Hefei, Anhui, P. R. Ch…. Hauptthemen laut MEDLINE: Sweat, Wearable Electronic Devices, Luminescent Measurements, Electrochemical Techniques. Die Arbeit wurde bisher 23-mal zitiert (Crossref) und nennt 57 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, Start-up fund of Hefei University of Technology, Fundamental Research Funds for the Central Universities.
Abstract (Originalsprache)
Wearable sensors are transforming real‐time, non‐invasive health monitoring. Despite considerable advances in electrochemical and optical sensing modalities, challenges remain in achieving reliable, sensitive, and cost‐effective detection of sweat metabolites due to the variable chemical composition of sweat and difficulties in device integration. Electrochemiluminescence (ECL) offers an attractive alternative for wearable sensing due to its high sensitivity and ease of integration without complex circuitry or external light sources. However, ECL is rarely used in wearable formats due to challenges in flexible electrode and stable luminophore development. Here, we present a fully soft, skin‐conformable ECL chip for sweat metabolite monitoring, integrating a laser‐patterned closed bipolar electrode array, a microfluidic sweat collector, and deep eutectic solvent‐based ionogels as robust ECL emitters. This architecture separates sensing and reporting zones, effectively reducing signal interference from complex sweat matrices, while the ionogels enhance signal stability and device flexibility, enabling prolonged on‐skin operation. Taking glucose as a model analyte, we demonstrate specific and direct ECL readout by integrating a specific enzymatic reaction with a linear range from µ m to m m . The device accurately captures postprandial glucose changes, with a per‐chip cost of $0.106, demonstrating its great potential for real‐time metabolic tracking in personalized health monitoring or clinical diagnosis.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Key Laboratory of Precision and Intelligent Chemistry, Department of Chemistry, University of Science and Technology of China, Hefei, Anhui, P. R. China.
- Department of Biomedical Engineering, School of Instrument Science and Opto-electronics Engineering, Hefei University of Technology, Hefei, Anhui, P. R. China.
Förderung
- National Natural Science Foundation of China
- Start-up fund of Hefei University of Technology
- Fundamental Research Funds for the Central Universities
Zitieren
APA
Nie, W., Jiang, J., Wei, X., Zhuo, L., Li, D., Jia, M., Zheng, T., & Cui, H. (2026). An All‐Soft Wearable Electrochemiluminescence Chip for Sweat Metabolite Detection. Advanced Science, 13(10). https://doi.org/10.1002/advs.202519435
Vancouver
Nie W, Jiang J, Wei X, Zhuo L, Li D, Jia M, et al. An All‐Soft Wearable Electrochemiluminescence Chip for Sweat Metabolite Detection. Advanced Science. 2026;13(10). doi:10.1002/advs.202519435
BibTeX
@article{Nie2026,
author = {Nie, Wei and Jiang, Jie and Wei, Xi and Zhuo, Linfeng and Li, Danyang and Jia, Mingyu and Zheng, Tianhua and Cui, Hua},
title = {An All‐Soft Wearable Electrochemiluminescence Chip for Sweat Metabolite Detection},
journal = {Advanced Science},
year = {2026},
volume = {13},
number = {10},
doi = {10.1002/advs.202519435}
}
EUVIMED