Stretchable and High‐Performance Fibrous Sensors Based on Ionic Capacitive Sensing for Wearable Healthcare Monitoring
Advanced Science · 2025-01 · 12 (1)
DOI: 10.1002/advs.202412859 ↗Kurz gefasst
Fachartikel in der Zeitschrift Advanced Science, online erschienen am 11.11.2024. Verfasst von Jiawei Liu und 8 weiteren Autor:innen. Beteiligte Einrichtung: School of Mechanical Engineering, Sichuan University, Chengdu, 610065, China. Hauptthemen laut MEDLINE: Wearable Electronic Devices, Textiles, Equipment Design. Die Arbeit wurde bisher 38-mal zitiert (Crossref) und nennt 46 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Sichuan Provincial Science and Technology Fund for Distinguished Young Scholars, Research Startup Fund by Sichuan University, National Natural Science Foundation of China (NSFC) - Excellent Young Scientists Fund (Oversea).
Abstract (Originalsprache)
Electronic textiles with remarkable breathability, lightweight, and comfort hold great potential in wearable technologies and smart human‐machine interfaces. Ionic capacitive sensors, leveraging the advantages of the electric double layer, offer higher sensitivity compared to traditional capacitive sensors. Current research on wearable ion‐capacitive sensors has focused mainly on two‐dimensional (2D) or three‐dimensional (3D) device architectures, which show substantial challenges for direct integration with textiles and compromise their wearing experience on conformability and permeability. One‐dimensional (1D) stretchable fiber materials serve as vital components in constructing electronic textiles, allowing for rich structural design, patterning, and device integration through mature textile techniques. Here, a stretchable functional fiber with robust mechanical and electrical performances is fabricated based on semi‐solid metal and ionic polymer, which provided a high stretchability and good electrical conductivity, enabling seamless integration with textiles. Consequently, high‐performance stretchable fiber sensors are developed through different device architecture designs, including pressure sensors with high sensitivity (7.21 kPa −1 ), fast response (60 ms/30 ms), and excellent stability, as well as strain sensors with high sensitivity (GF = 1.05), wide detection range (0–300% strain), and excellent sensing stability under dynamic deformations.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of Mechanical Engineering, Sichuan University, Chengdu, 610065, China.
ORCID-Profile: Jiangxin Wang
Förderung
- Sichuan Provincial Science and Technology Fund for Distinguished Young Scholars
- Research Startup Fund by Sichuan University
- National Natural Science Foundation of China (NSFC) - Excellent Young Scientists Fund (Oversea)
Zitieren
APA
Liu, J., Yang, Y., Chen, G., Sun, H., Xie, X., Hou, Y., Zhang, L., Wang, J., & Wang, J. (2025). Stretchable and High‐Performance Fibrous Sensors Based on Ionic Capacitive Sensing for Wearable Healthcare Monitoring. Advanced Science, 12(1). https://doi.org/10.1002/advs.202412859
Vancouver
Liu J, Yang Y, Chen G, Sun H, Xie X, Hou Y, et al. Stretchable and High‐Performance Fibrous Sensors Based on Ionic Capacitive Sensing for Wearable Healthcare Monitoring. Advanced Science. 2025;12(1). doi:10.1002/advs.202412859
BibTeX
@article{Liu2025,
author = {Liu, Jiawei and Yang, Yan and Chen, Guangchuan and Sun, Hongbiao and Xie, Xin and Hou, Yanfeng and Zhang, Lishen and Wang, Jinhui and Wang, Jiangxin},
title = {Stretchable and High‐Performance Fibrous Sensors Based on Ionic Capacitive Sensing for Wearable Healthcare Monitoring},
journal = {Advanced Science},
year = {2025},
volume = {12},
number = {1},
doi = {10.1002/advs.202412859}
}
EUVIMED