EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Fabric on fabric: A conductive fabric‐based wearable coil using cutting plotter for MRI at 3T

Thejas Vishnu Ramesh iD, Sergio Martin-Moreno iD, Folk W Narongrit, Christopher J S Chang, Vitaliy L Rayz, Joseph V Rispoli iD

Magnetic Resonance in Medicine · 2026-01 · 95 (1) · 647-660

DOI: 10.1002/mrm.70051 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, online erschienen am 02.09.2025. Verfasst von Thejas Vishnu Ramesh und 5 weiteren Autor:innen. Beteiligte Einrichtung: Weldon School of Biomedical Engineering, Purdue University, West Lafayette, Indiana, USA. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Wearable Electronic Devices, Textiles. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 56 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: NIBIB NIH HHS, National Institute of Biomedical Imaging and Bioengineering.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Wearable coils fabricated using conductive threads have high resistance that limits SNR. The purpose of this work is to demonstrate the utility of conductive fabric as a coil conductor that can be fabricated using a cutting plotter.

Methods

A single‐channel coil was developed by feeding a conductive fabric sheet into an automatic cutting plotter. The fabric coil was loaded on a spherical phantom to evaluate SNR and B 1 + homogeneity and compared with a single‐channel conductive thread coil and a rigid printed circuit board (PCB) coil. A 14‐channel wearable neck array was developed for structural imaging of the cervical spine and 4D flow MRI of the carotid arteries. The SNR from structural images and velocity‐to‐noise ratio (VNR) from flow images were compared with a 16‐channel commercial coil.

Results

The single‐channel conductive fabric coil provided 6.7% and 125.9% SNR increase when compared to the rigid PCB and conductive thread coils across 10 scan repetitions. The B 1 + field homogeneity was 96.4%, 1% higher than the rigid PCB and conductive thread coils. The wearable neck array demonstrated a 51.1% average SNR increase from the cervical spine images across three volunteers and a 12.0% VNR increase from the postprocessed 4D flow data when compared with the commercial 16‐channel array.

Conclusion

The possibility of developing wearable coils using conductive fabric to enhance SNR in structural images and VNR in 4D flow images is demonstrated. The conductive fabric technique enables fabrication on commercial garments resulting in form‐fitting wearable coils.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Resonance ImagingWearable Electronic DevicesTextilesHumansPhantoms, ImagingEquipment DesignSignal-To-Noise RatioCarotid ArteriesCervical VertebraeElectric ConductivityImage Processing, Computer-Assisted

Stichwörter der Autor:innen

4D flow imagingMRI coilsSNRcarotid arteriescervical spinevelocity‐to‐noise ratiowearable coils

Autor:innen und Institutionen

  • Weldon School of Biomedical Engineering, Purdue University, West Lafayette, Indiana, USA.
  • Elmore Family School of Electrical and Computer Engineering, Purdue University, West Lafayette, Indiana, USA.
  • School of Mechanical Engineering, Purdue University, West Lafayette, Indiana, USA.
  • Department of Radiology and Medical Imaging, University of Virginia, Charlottesville, Virginia, USA.

ORCID-Profile: Thejas Vishnu Ramesh, Sergio Martin-Moreno, Joseph V Rispoli

Förderung

  • NIBIB NIH HHS
  • National Institute of Biomedical Imaging and Bioengineering

Zitieren

APA

Ramesh, T. V., Martin-Moreno, S., Narongrit, F. W., Chang, C. J. S., Rayz, V. L., & Rispoli, J. V. (2026). Fabric on fabric: A conductive fabric‐based wearable coil using cutting plotter for MRI at 3T. Magnetic Resonance in Medicine, 95(1), 647-660. https://doi.org/10.1002/mrm.70051

Vancouver

Ramesh TV, Martin-Moreno S, Narongrit FW, Chang CJS, Rayz VL, Rispoli JV. Fabric on fabric: A conductive fabric‐based wearable coil using cutting plotter for MRI at 3T. Magnetic Resonance in Medicine. 2026;95(1):647-660. doi:10.1002/mrm.70051

BibTeX
@article{Ramesh2026,
  author = {Ramesh, Thejas Vishnu and Martin-Moreno, Sergio and Narongrit, Folk W and Chang, Christopher J S and Rayz, Vitaliy L and Rispoli, Joseph V},
  title = {Fabric on fabric: A conductive fabric‐based wearable coil using cutting plotter for MRI at 3T},
  journal = {Magnetic Resonance in Medicine},
  year = {2026},
  volume = {95},
  number = {1},
  pages = {647--660},
  doi = {10.1002/mrm.70051}
}
Kostenlos starten →