Learning Hand Kinematics for Parkinson's Disease Assessment Using a Multimodal Sensor Glove

Yu Li, Junyi Yin iD, Shuoyan Liu, Bing Xue, Cyrus Shokoohi, Gang Ge iD, Menglei Hu, Tenghuan Li, Xue Tao, Zhi Rao, Fanye Meng, Hongfeng Shi und 4 weitere

Advanced Science · 2023-07 · 10 (20)

DOI: 10.1002/advs.202206982 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Advanced Science, online erschienen am 07.05.2023. Verfasst von Yu Li und 15 weiteren Autor:innen. Beteiligte Einrichtung: School of Life Science and Technology, Changchun University of Science and Technology, Changchun, 130022, P. R. China. Hauptthemen laut MEDLINE: Parkinson Disease. Die Arbeit wurde bisher 54-mal zitiert (Crossref) und nennt 60 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Science and Technology Development Plan Project of Jilin Province, National Research Foundation, Singapore and A*STAR under its RIE2020 Industry Alignment Fund - Industry Collaboration Projects (IAF-ICP) grant call, Catalyzing Pediatric Innovation Grant.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Hand dysfunctions in Parkinson's disease include rigidity, muscle weakness, and tremor, which can severely affect the patient's daily life. Herein, a multimodal sensor glove is developed for quantifying the severity of Parkinson's disease symptoms in patients’ hands while assessing the hands’ multifunctionality. Toward signal processing, various algorithms are used to quantify and analyze each signal: Exponentially Weighted Average algorithm and Kalman filter are used to filter out noise, normalization to process bending signals, K‐Means Cluster Analysis to classify muscle strength grades, and Back Propagation Neural Network to identify and classify tremor signals with an accuracy of 95.83%. Given the compelling features, the flexibility, muscle strength, and stability assessed by the glove and the clinical observations are proved to be highly consistent with Kappa values of 0.833, 0.867, and 0.937, respectively. The intraclass correlation coefficients obtained by reliability evaluation experiments for the three assessments are greater than 0.9, indicating that the system is reliable. The glove can be applied to assist in formulating targeted rehabilitation treatments and improve hand recovery efficiency.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Parkinson DiseaseHumansTremorReproducibility of ResultsBiomechanical PhenomenaHand

Stichwörter der Autor:innen

Parkinson's diseasefinger flexibilityhand muscle strengthhand stabilitysmart glovewearable bioelectronics

Autor:innen und Institutionen

  • School of Life Science and Technology, Changchun University of Science and Technology, Changchun, 130022, P. R. China.
  • Department of Bioengineering, University of California, Los Angeles, Los Angeles, CA, 90095, USA.
  • Department of Materials Science and Engineering, National University of Singapore, Singapore, 117583, Singapore.
  • Department of Electrical and Computer Engineering, National University of Singapore, Singapore, 117583, Singapore.
  • Department of Electrical and Computer Engineering, University of British Columbia, Vancouver, BC, V6T1Z4, Canada.
  • China-Japan Union Hospital of Jilin University, Changchun, 130033, P. R. China.

ORCID-Profile: Junyi Yin, Gang Ge, Xiao Xiao

Förderung

  • Science and Technology Development Plan Project of Jilin Province
  • National Research Foundation, Singapore and A*STAR under its RIE2020 Industry Alignment Fund - Industry Collaboration Projects (IAF-ICP) grant call
  • Catalyzing Pediatric Innovation Grant
  • Henry Samueli School of Engineering & Applied Science and the Department of Bioengineering at the University of California, Los Angeles
  • Hellman Fellows Research Grant
  • UCLA Pandemic Resources Program Research Award
  • Research Recovery Grant by the UCLA Academic Senate

Zitieren

APA

Li, Y., Yin, J., Liu, S., Xue, B., Shokoohi, C., Ge, G., Hu, M., Li, T., Tao, X., Rao, Z., Meng, F., Shi, H., Ji, X., Servati, P., Xiao, X., & Chen, J. (2023). Learning Hand Kinematics for Parkinson's Disease Assessment Using a Multimodal Sensor Glove. Advanced Science, 10(20). https://doi.org/10.1002/advs.202206982

Vancouver

Li Y, Yin J, Liu S, Xue B, Shokoohi C, Ge G, et al. Learning Hand Kinematics for Parkinson's Disease Assessment Using a Multimodal Sensor Glove. Advanced Science. 2023;10(20). doi:10.1002/advs.202206982

BibTeX
@article{Li2023,
  author = {Li, Yu and Yin, Junyi and Liu, Shuoyan and Xue, Bing and Shokoohi, Cyrus and Ge, Gang and Hu, Menglei and Li, Tenghuan and Tao, Xue and Rao, Zhi and Meng, Fanye and Shi, Hongfeng and Ji, Xiaoqiang and Servati, Peyman and Xiao, Xiao and Chen, Jun},
  title = {Learning Hand Kinematics for Parkinson's Disease Assessment Using a Multimodal Sensor Glove},
  journal = {Advanced Science},
  year = {2023},
  volume = {10},
  number = {20},
  doi = {10.1002/advs.202206982}
}
Kostenlos starten →