EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Towards a Modular Pathological Tremor Simulation System Based on the Stewart Platform

Jair Fajardo, Leonimer Flávio de Melo

Sensors · 2023

DOI: 10.3390/s23229020 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, 2023. Verfasst von Jair Fajardo und 1 weiteren Autor:innen. Beteiligte Einrichtung: Federal Institute of Paraná, Assis Chateaubriand Campus, Assis Chateaubriand 85935-000, Brazil. Hauptthemen laut MEDLINE: Tremor, Parkinson Disease. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Wearable technologies have aided in reducing pathological tremor symptoms through non-intrusive solutions that aim to identify patterns in involuntary movements and suppress them using actuators positioned at specific joints. However, during the development of these devices, tests were primarily conducted on patients due to the difficulty of faithfully simulating tremors using simulation equipment. Based on studies characterizing tremors in Parkinson’s disease, the development of a robotic manipulator based on the Stewart platform was initiated, with the goal of satisfactorily simulating resting tremor movements in the hands. In this work, a simulator was implemented in a computational environment using the multibody dynamics method. The platform structure was designed in a virtual environment using SOLIDWORKS® v2017 software and later exported to Matlab® R17a software using the Simulink environment and Simscape multibody library. The workspace was evaluated, and the Kalman filter was used to merge acceleration and angular velocity data and convert them into data related to the inclination and rotation of real patients’ wrists, which were subsequently executed in the simulator. The results show a high correlation and low dispersion between real and simulated signals, demonstrating that the simulated mechanism has the capacity to represent Parkinson’s disease resting tremors in all wrist movements. The system could contribute to conducting tremor tests in suppression devices without the need for the presence of the patient and aid in comparing suppression techniques, benefiting the development of new wearable devices.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

TremorParkinson DiseaseHumansHandWristAcceleration

Stichwörter der Autor:innen

Kalman filterParkinson’s diseaseassistive technologiesmultibody dynamicssensor fusionsystems modelingtremor simulationwearable devices

Autor:innen und Institutionen

  • Federal Institute of Paraná, Assis Chateaubriand Campus, Assis Chateaubriand 85935-000, Brazil.
  • Department of Electrical Engineering, State University of Londrina, Londrina 86057-970, Brazil.

Zitieren

APA

Fajardo, J., & Melo, L. F. (2023). Towards a Modular Pathological Tremor Simulation System Based on the Stewart Platform. Sensors. https://doi.org/10.3390/s23229020

Vancouver

Fajardo J, Melo LF. Towards a Modular Pathological Tremor Simulation System Based on the Stewart Platform. Sensors. 2023. doi:10.3390/s23229020

BibTeX
@article{Fajardo2023,
  author = {Fajardo, Jair and Melo, Leonimer Flávio de},
  title = {Towards a Modular Pathological Tremor Simulation System Based on the Stewart Platform},
  journal = {Sensors},
  year = {2023},
  doi = {10.3390/s23229020}
}
Kostenlos starten →