Effects of Sterilization on Cellobiose Dehydrogenase and Glucose Oxidase Based Glucose Biosensors

Richard Bennett, Arvind Rathore, Sébastien Gounel, Anna Lielpetere, Thomas M.B. Reichhart, Kavita Jayakumar, Roland Ludwig, Alfons K.G. Felice, Dónal Leech, Wolfgang Schuhmann, Andrew Mount, Nicolas Mano und 1 weitere

Advanced Sensor Research · 2024-11 · 3 (11)

DOI: 10.1002/adsr.202400056 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Advanced Sensor Research, online erschienen am 18.09.2024. Verfasst von Richard Bennett und 12 weiteren Autor:innen. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 51 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: H2020 Marie Skłodowska-Curie Actions.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Research on implantable glucose biosensors is driven by the need for innovative medical devices for continuous glucose monitoring in patients with diabetes mellitus. However, biosensor sterilization is a step that is widely omitted during the process of innovation. To compare the effects of gamma irradiation and chemical treatment with ethylene oxide (carbon microarray electrodes are fabricated, functionalized with glucose oxidizing enzymes (cellobiose dehydrogenase CDH or glucose oxidase GOx), and coated with a specifically designed zwitterionic polymer prior to the sterilization step. Cyclic voltammetry in the presence of 100 m m glucose of the biosensors before and after sterilization shows that gamma irradiation with a low radiation rate (25 kGy, 260 Gy h −1 ) does not induce a sensor performance loss, unlike the EtO treatment. In addition, no cytotoxic by‐products are released after gamma sterilization. Based on these results obtained with both glucose oxidizing enzymes (CDH and GOx), gamma irradiation of the glucose biosensors with a low dose rate is preferable to exposure to EtO for biosensor terminal sterilization.

Förderung

  • H2020 Marie Skłodowska-Curie Actions

Zitieren

APA

Bennett, R., Rathore, A., Gounel, S., Lielpetere, A., Reichhart, T. M., Jayakumar, K., Ludwig, R., Felice, A. K., Leech, D., Schuhmann, W., Mount, A., Mano, N., & Boiziau, C. (2024). Effects of Sterilization on Cellobiose Dehydrogenase and Glucose Oxidase Based Glucose Biosensors. Advanced Sensor Research, 3(11). https://doi.org/10.1002/adsr.202400056

Vancouver

Bennett R, Rathore A, Gounel S, Lielpetere A, Reichhart TM, Jayakumar K, et al. Effects of Sterilization on Cellobiose Dehydrogenase and Glucose Oxidase Based Glucose Biosensors. Advanced Sensor Research. 2024;3(11). doi:10.1002/adsr.202400056

BibTeX
@article{Bennett2024,
  author = {Bennett, Richard and Rathore, Arvind and Gounel, Sébastien and Lielpetere, Anna and Reichhart, Thomas M.B. and Jayakumar, Kavita and Ludwig, Roland and Felice, Alfons K.G. and Leech, Dónal and Schuhmann, Wolfgang and Mount, Andrew and Mano, Nicolas and Boiziau, Claudine},
  title = {Effects of Sterilization on Cellobiose Dehydrogenase and Glucose Oxidase Based Glucose Biosensors},
  journal = {Advanced Sensor Research},
  year = {2024},
  volume = {3},
  number = {11},
  doi = {10.1002/adsr.202400056}
}
Kostenlos starten →