Novel Enzymatic Reagentless Glucose Biosensors Based on Noble Metal Nanostructures
Polymers · 22.05.2026 · 18 (11) · 1273
DOI: 10.3390/polym18111273 ↗Kurz gefasst
Fachartikel in der Zeitschrift Polymers, online erschienen am 22.05.2026. Verfasst von Natalija German und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Immunology and Bioelectrochemistry, State Research Institute Centre for Innovative Medicine, Santariskiu 5, LT-08406 Vilnius, Lithuania. Die Arbeit nennt 58 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Reagentless glucose biosensors with redox mediator—polymerized 1,10-phenanthroline-5,6-dione (pPD)—were developed and electrochemically investigated. Three types of biosensors based on graphite rod (GR) electrodes modified by (i) 13 nm of gold nanoparticles (AuNPs), (ii) electrochemically synthesized dendritic gold nanostructures (DAuNSs), and (iii) platinum nanostructures (PtNSs) were prepared. All electrodes were modified by glucose oxidase (GOx), and the pPD was polymerized for 2 h. Thus, GR/AuNPs/GOx/pPD, GR/DAuNSs/GOx/pPD, and GR/PtNSs/GOx/pPD electrodes were developed and electrochemically characterized. The electrode without noble metal nanostructures (GR/GOx/pPD) was used as the control. The biosensor based on the GR/DAuNSs/GOx/pPD electrode exhibited the best performance, with the sensitivity of 2.58 μA/(mM cm2), the linear range up to 93.7 mM, the limit of detection 0.182 mM, the reproducibility and repeatability of 4.99 and 4.80%, and the storage stability (50% of initial current responses (t1/2)) for up to 19 days. The achieved high resistance to interfering materials enabled precise glucose detection in real samples, including human serum and beverages. The technological solutions presented in this paper are anticipated to provide opportunities and benefits of developing novel enzymatic reagentless glucose biosensors based on noble metal nanostructures for use in clinical assays and general diagnostics, including blood glucose monitoring in people with diabetes.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Immunology and Bioelectrochemistry, State Research Institute Centre for Innovative Medicine, Santariskiu 5, LT-08406 Vilnius, Lithuania.
- NanoTechnas-Center of Nanotechnology and Materials Science, Institute of Chemistry, Faculty of Chemistry and Geosciences, Vilnius University, LT-03225 Vilnius, Lithuania.
ORCID-Profile: Natalija German, Anton Popov, Almira Ramanaviciene
Zitieren
APA
German, N., Popov, A., & Ramanaviciene, A. (2026). Novel Enzymatic Reagentless Glucose Biosensors Based on Noble Metal Nanostructures. Polymers, 18(11), 1273. https://doi.org/10.3390/polym18111273
Vancouver
German N, Popov A, Ramanaviciene A. Novel Enzymatic Reagentless Glucose Biosensors Based on Noble Metal Nanostructures. Polymers. 2026;18(11):1273. doi:10.3390/polym18111273
BibTeX
@article{German2026,
author = {German, Natalija and Popov, Anton and Ramanaviciene, Almira},
title = {Novel Enzymatic Reagentless Glucose Biosensors Based on Noble Metal Nanostructures},
journal = {Polymers},
year = {2026},
volume = {18},
number = {11},
pages = {1273},
doi = {10.3390/polym18111273}
}