EUVIMEDOpdag EUVIMED
Open access · CC BY 4.0

Evaluation of Dynamic Anatomical Ultrasonography for Tracking Layer‐Thickness Changes in Residuum‐Inspired Mechano‐Acoustic Phantoms

Alireza Y. Bavil, Christian Langton, Nataliya Perevoshchikova, Jayishni Maharaj, Rod Barrett, David Lloyd, Stefanie Feih, Laurent Frossard

Advanced Materials Technologies · 2026-11-18

DOI: 10.1002/admt.71456 ↗

At a glance

Journal article in Advanced Materials Technologies, published online on 2026-11-18. Written by Alireza Y. Bavil and 7 co-authors. 55 references. The full text is freely available (open access, CC BY 4.0).

AbstractBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Assessing ultrasound measurements in deforming soft tissues requires material platforms that reproduce both acoustic and mechanical behavior under load. This study developed multilayer mechano‐acoustic phantoms to evaluate Dynamic Anatomical Ultrasonography (DAU) for assessing deformation of internal soft‐tissue layers, with application to the residuum of people with limb loss. Silicone‐based tissue‐mimicking materials representing skin, adipose, and muscle were acoustically characterized and assembled into phantoms with and without Nylon‐12 interlayers. The phantoms were tested under uniaxial compression with synchronized DAU, force, and video recordings, and represented by finite element (FE) models mechanically calibrated using reaction forces and external thickness changes. Minimal acoustic contrast between silicone layers limited interface detectability, whereas incorporation of interlayers improved tracking. FE models in both phantom configurations showed that surface tracking was a poor proxy for internal layer‐thickness changes. Across layers, mean absolute errors between DAU‐derived and FE‐predicted thickness reductions ranged from 0.015 to 0.17 mm in the phantom with interlayers and from 0.032 to 0.37 mm in the phantom without interlayers. These findings establish a framework for model‐referenced evaluation of DAU in multilayer soft‐tissue systems and support future in‐vitro and in ‐ vivo studies relevant to residuum assessment and prosthetic socket design.

Cite

APA

Bavil, A. Y., Langton, C., Perevoshchikova, N., Maharaj, J., Barrett, R., Lloyd, D., Feih, S., & Frossard, L. (2026). Evaluation of Dynamic Anatomical Ultrasonography for Tracking Layer‐Thickness Changes in Residuum‐Inspired Mechano‐Acoustic Phantoms. Advanced Materials Technologies. https://doi.org/10.1002/admt.71456

Vancouver

Bavil AY, Langton C, Perevoshchikova N, Maharaj J, Barrett R, Lloyd D, et al. Evaluation of Dynamic Anatomical Ultrasonography for Tracking Layer‐Thickness Changes in Residuum‐Inspired Mechano‐Acoustic Phantoms. Advanced Materials Technologies. 2026. doi:10.1002/admt.71456

BibTeX
@article{Bavil2026,
  author = {Bavil, Alireza Y. and Langton, Christian and Perevoshchikova, Nataliya and Maharaj, Jayishni and Barrett, Rod and Lloyd, David and Feih, Stefanie and Frossard, Laurent},
  title = {Evaluation of Dynamic Anatomical Ultrasonography for Tracking Layer‐Thickness Changes in Residuum‐Inspired Mechano‐Acoustic Phantoms},
  journal = {Advanced Materials Technologies},
  year = {2026},
  doi = {10.1002/admt.71456}
}
Start for free →