Evaluation of Dynamic Anatomical Ultrasonography for Tracking Layer‐Thickness Changes in Residuum‐Inspired Mechano‐Acoustic Phantoms
Advanced Materials Technologies · 18.11.2026
DOI: 10.1002/admt.71456 ↗Kurz gefasst
Fachartikel in der Zeitschrift Advanced Materials Technologies, online erschienen am 18.11.2026. Verfasst von Alireza Y. Bavil und 7 weiteren Autor:innen. Die Arbeit nennt 55 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Assessing ultrasound measurements in deforming soft tissues requires material platforms that reproduce both acoustic and mechanical behavior under load. This study developed multilayer mechano‐acoustic phantoms to evaluate Dynamic Anatomical Ultrasonography (DAU) for assessing deformation of internal soft‐tissue layers, with application to the residuum of people with limb loss. Silicone‐based tissue‐mimicking materials representing skin, adipose, and muscle were acoustically characterized and assembled into phantoms with and without Nylon‐12 interlayers. The phantoms were tested under uniaxial compression with synchronized DAU, force, and video recordings, and represented by finite element (FE) models mechanically calibrated using reaction forces and external thickness changes. Minimal acoustic contrast between silicone layers limited interface detectability, whereas incorporation of interlayers improved tracking. FE models in both phantom configurations showed that surface tracking was a poor proxy for internal layer‐thickness changes. Across layers, mean absolute errors between DAU‐derived and FE‐predicted thickness reductions ranged from 0.015 to 0.17 mm in the phantom with interlayers and from 0.032 to 0.37 mm in the phantom without interlayers. These findings establish a framework for model‐referenced evaluation of DAU in multilayer soft‐tissue systems and support future in‐vitro and in ‐ vivo studies relevant to residuum assessment and prosthetic socket design.
Zitieren
APA
Bavil, A. Y., Langton, C., Perevoshchikova, N., Maharaj, J., Barrett, R., Lloyd, D., Feih, S., & Frossard, L. (2026). Evaluation of Dynamic Anatomical Ultrasonography for Tracking Layer‐Thickness Changes in Residuum‐Inspired Mechano‐Acoustic Phantoms. Advanced Materials Technologies. https://doi.org/10.1002/admt.71456
Vancouver
Bavil AY, Langton C, Perevoshchikova N, Maharaj J, Barrett R, Lloyd D, et al. Evaluation of Dynamic Anatomical Ultrasonography for Tracking Layer‐Thickness Changes in Residuum‐Inspired Mechano‐Acoustic Phantoms. Advanced Materials Technologies. 2026. doi:10.1002/admt.71456
BibTeX
@article{Bavil2026,
author = {Bavil, Alireza Y. and Langton, Christian and Perevoshchikova, Nataliya and Maharaj, Jayishni and Barrett, Rod and Lloyd, David and Feih, Stefanie and Frossard, Laurent},
title = {Evaluation of Dynamic Anatomical Ultrasonography for Tracking Layer‐Thickness Changes in Residuum‐Inspired Mechano‐Acoustic Phantoms},
journal = {Advanced Materials Technologies},
year = {2026},
doi = {10.1002/admt.71456}
}
EUVIMED