EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Flexible Polypyrrole‐Based pH Sensors via Oxidative Chemical Vapor Deposition

Adrivit Mukherjee, Federico Ferrari, David Garcia Romero, Ilaria Squillante, Job Schoenmaker, Hamoon Hemmatpour, Anton Terpstra, Peter Dijkstra, Julien Es Sayed, L Jan Anton Koster, Maria Antonietta Loi, Petra Rudolf und 4 weitere

Advanced Healthcare Materials · 2026-04 · 15 (16)

DOI: 10.1002/adhm.202505807 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Advanced Healthcare Materials, online erschienen am 03.02.2026. Verfasst von Adrivit Mukherjee und 15 weiteren Autor:innen. Beteiligte Einrichtung: Chemical Product Engineering, Faculty of Science and Engineering, Engineering and Technology Institute Groningen (ENTEG), University of Groningen, Gr…. Hauptthemen laut MEDLINE: Pyrroles, Polymers, Biosensing Techniques. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 86 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: European Research Council.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The dynamic physicochemical environment of healing wounds provides valuable diagnostic information, with pH serving as a key biomarker for infection, inflammation, and tissue regeneration. However, the development of flexible, biocompatible, and stable pH sensors that can be seamlessly integrated into wearable platforms remains challenging. Here, we report a strategy to fabricate electrically conductive, pH‐responsive bioelectronic sensors based on ultrathin polypyrrole (PPy) films deposited via oxidative chemical vapor deposition (oCVD). The resulting flexible sensors enable monitoring of physiologically relevant pH changes (4–9) and exhibit modulation of electrical conductivity up to two orders of magnitude, reaching 304 S.cm −1 (pH 4). Grazing‐incidence wide‐angle X‐ray scattering reveals enhanced structural order and efficient π–π stacking with increasing dopant concentration, leading to improved charge transport. Complementary spectroscopic analyses demonstrate that reversible protonation‐deprotonation of the PPy backbone, governed by dopant counterion exchange, underlies the pH‐dependent electrical response. The all‐polymer pH sensors display high sensitivity, stability, and repeatability. Moreover, the substrate‐independent nature of oCVD enables the fabrication of pH‐sensing patches and spatially patterned micro‐islands, facilitating seamless integration into smart wound dressings for spatiotemporally resolved bioelectronic monitoring. This work advances the design of flexible, wearable pH sensors and provides opportunities for real‐time wound‐healing monitoring.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

PyrrolesPolymersBiosensing TechniquesHydrogen-Ion ConcentrationElectric ConductivityOxidation-ReductionHumans

Stichwörter der Autor:innen

bioelectronic sensorselectrically conductive polypyrroleoxidative chemical vapor depositionpH sensorsmart skin‐integrated wearablesspatiotemporal (bio)sensingwound healing monitoring

Substanzen

PyrrolesPolymerspolypyrrole

Autor:innen und Institutionen

  • Chemical Product Engineering, Faculty of Science and Engineering, Engineering and Technology Institute Groningen (ENTEG), University of Groningen, Groningen, The Netherlands.
  • Polymer Science, Faculty of Science and Engineering, Zernike Institute for Advanced Materials (ZIAM), University of Groningen, Groningen, The Netherlands.
  • Bioinspired MEMS and Biomedical Devices Group, Faculty of Science and Engineering, Engineering and Technology Institute Groningen (ENTEG), University of Groningen, Groningen, The Netherlands.
  • Photophysics and Optoelectronics, Faculty of Science and Engineering, Zernike Institute for Advanced Materials (ZIAM), University of Groningen, Groningen, The Netherlands.
  • Physical Chemistry of Polymeric and Nanostructured Materials, Faculty of Science and Engineering, Zernike Institute for Advanced Materials (ZIAM), University of Groningen, Groningen, The Netherlands.
  • Surfaces and Thin Films, Faculty of Science and Engineering, Zernike Institute for Advanced Materials (ZIAM), University of Groningen, Groningen, The Netherlands.

ORCID-Profile: Ranjita K Bose

Förderung

  • European Research Council

Zitieren

APA

Mukherjee, A., Ferrari, F., Romero, D. G., Squillante, I., Schoenmaker, J., Hemmatpour, H., Terpstra, A., Dijkstra, P., Sayed, J. E., Koster, L. J. A., Loi, M. A., Rudolf, P., Portale, G., Kottapalli, A. G. P., Kamperman, M., & Bose, R. K. (2026). Flexible Polypyrrole‐Based pH Sensors via Oxidative Chemical Vapor Deposition. Advanced Healthcare Materials, 15(16). https://doi.org/10.1002/adhm.202505807

Vancouver

Mukherjee A, Ferrari F, Romero DG, Squillante I, Schoenmaker J, Hemmatpour H, et al. Flexible Polypyrrole‐Based pH Sensors via Oxidative Chemical Vapor Deposition. Advanced Healthcare Materials. 2026;15(16). doi:10.1002/adhm.202505807

BibTeX
@article{Mukherjee2026,
  author = {Mukherjee, Adrivit and Ferrari, Federico and Romero, David Garcia and Squillante, Ilaria and Schoenmaker, Job and Hemmatpour, Hamoon and Terpstra, Anton and Dijkstra, Peter and Sayed, Julien Es and Koster, L Jan Anton and Loi, Maria Antonietta and Rudolf, Petra and Portale, Giuseppe and Kottapalli, Ajay Giri Prakash and Kamperman, Marleen and Bose, Ranjita K},
  title = {Flexible Polypyrrole‐Based pH Sensors via Oxidative Chemical Vapor Deposition},
  journal = {Advanced Healthcare Materials},
  year = {2026},
  volume = {15},
  number = {16},
  doi = {10.1002/adhm.202505807}
}
Kostenlos starten →