3D‐Printed Multidimensional Bionic Mg‐MC/PLGA Composite for Tailored Repair of Segmental Long Bone Defects
Advanced Healthcare Materials · 2025-11 · 14 (29)
DOI: 10.1002/adhm.202501938 ↗Kurz gefasst
Fachartikel in der Zeitschrift Advanced Healthcare Materials, online erschienen am 29.07.2025. Verfasst von Shihang Liu und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedic Surgery, Hebei Medical University Third Hospital, No.139 Ziqiang Road, Shijiazhuang, 050051, P. R. China. Hauptthemen laut MEDLINE: Printing, Three-Dimensional, Magnesium, Tissue Scaffolds, Bone Regeneration. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 54 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
The management of long bone segmental defects represents a critical challenge in orthopedic medicine. This study focuses on developing an innovative bone repair material to overcome the inherent limitations of existing solutions. The material is synthesized by incorporating magnesium into mineralized collagen to produce Mg‐MC bone powder, which is then combined with polylactic acid‐hydroxyglycolic acid copolymer (PLGA). Using advanced 3D printing and femtosecond laser techniques, Mg‐MC/PLGA scaffolds with varying magnesium concentrations (0%, 5%, 10%, 20%) are fabricated and characterized. In vitro studies demonstrate that the 5% Mg‐MC/PLGA scaffold exhibits superior cytocompatibility, cellular proliferation, migration, angiogenesis, and osteogenic activity, supported by elevated expression of osteogenic markers. In vivo experiments in a rabbit model confirm the efficacy of the 5% Mg 2 ⁺‐doped scaffold in promoting bone regeneration, with significant improvements in bone volume, trabecular thickness, and biomechanical strength. These findings highlight the potential of the 5% Mg‐MC/PLGA scaffold as a promising solution for the clinical treatment of bone defects.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Orthopaedic Surgery, Hebei Medical University Third Hospital, No.139 Ziqiang Road, Shijiazhuang, 050051, P. R. China.
- Xingtai People's Hospital, No.818 Xiangdu North Road, Xingtai, 054001, P.R. China.
- Key Laboratory of Biomechanics of Hebei Province, NHC Key Laboratory of Intelligent Orthopaedic Equipment, Orthopaedic Research Institution of Hebei Province, No.139 Ziqiang Road, Shijiazhuang, 050051, P. R. China.
- Engineering Research Center of Orthopedic Minimally Invasive Intelligent Equipment, Ministry of Education, Shijiazhuang, 050051, P. R. China.
- GPL Photonics Laboratory, Key Laboratory of Luminescence Science and Technology, Chinese Academy of Sciences & State Key Laboratory of Luminescence Science and Applications, Changchun Institute of Optics, Fine Mechanics…
ORCID-Profile: Hongzhi Lv
Zitieren
APA
Liu, S., Zhou, S., Zou, T., Hou, G., Xiao, Q., Li, L., Yang, J., Chen, W., Zhang, Y., & Lv, H. (2025). 3D‐Printed Multidimensional Bionic Mg‐MC/PLGA Composite for Tailored Repair of Segmental Long Bone Defects. Advanced Healthcare Materials, 14(29). https://doi.org/10.1002/adhm.202501938
Vancouver
Liu S, Zhou S, Zou T, Hou G, Xiao Q, Li L, et al. 3D‐Printed Multidimensional Bionic Mg‐MC/PLGA Composite for Tailored Repair of Segmental Long Bone Defects. Advanced Healthcare Materials. 2025;14(29). doi:10.1002/adhm.202501938
BibTeX
@article{Liu2025,
author = {Liu, Shihang and Zhou, Shuai and Zou, Tingting and Hou, Guangzhao and Xiao, Qian and Li, Lin and Yang, Jianjun and Chen, Wei and Zhang, Yingze and Lv, Hongzhi},
title = {3D‐Printed Multidimensional Bionic Mg‐MC/PLGA Composite for Tailored Repair of Segmental Long Bone Defects},
journal = {Advanced Healthcare Materials},
year = {2025},
volume = {14},
number = {29},
doi = {10.1002/adhm.202501938}
}