EUVIMEDObjevte EUVIMED
Open access · CC BY-NC-ND 4.0

Incorporating Tantalum Oxide Nanoparticles into Implantable Polymeric Biomedical Devices for Radiological Monitoring

Kendell M Pawelec iD, Ethan Tu, Shatadru Chakravarty iD, Jeremy M L Hix iD, Lane Buchanan, Legend Kenney, Foster Buchanan, Nandini Chatterjee, Subhashri Das, Adam Alessio, Erik M Shapiro iD

Advanced Healthcare Materials · 2023-07 · 12 (18)

DOI: 10.1002/adhm.202203167 ↗

At a glance

Journal article in Advanced Healthcare Materials, published online on 2023-03-13. Written by Kendell M Pawelec and 10 co-authors. Institution: Department of Radiology, Michigan State University, 846 Service Rd, East Lansing, MI, 48824, USA. Major MEDLINE topics: Oxides, Nanoparticles. Cited 26 times so far (Crossref); 47 references. The full text is freely available (open access, CC BY-NC-ND 4.0). Funded by: NIBIB NIH HHS, National Institute of Biomedical Imaging and Bioengineering, National Institutes of Health.

AbstraktSubjectsBibliografické údajeCiteRelated studies

Abstract (original language)

Longitudinal radiological monitoring of biomedical devices is increasingly important, driven by the risk of device failure following implantation. Polymeric devices are poorly visualized with clinical imaging, hampering efforts to use diagnostic imaging to predict failure and enable intervention. Introducing nanoparticle contrast agents into polymers is a potential method for creating radiopaque materials that can be monitored via computed tomography. However, the properties of composites may be altered with nanoparticle addition, jeopardizing device functionality. Thus, the material and biomechanical responses of model nanoparticle‐doped biomedical devices (phantoms), created from 0–40 wt% tantalum oxide (TaO x ) nanoparticles in polycaprolactone and poly(lactide‐co‐glycolide) 85:15 and 50:50, representing non, slow, and fast degrading systems, respectively, are investigated. Phantoms degrade over 20 weeks in vitro in simulated physiological environments: healthy tissue (pH 7.4), inflammation (pH 6.5), and lysosomal conditions (pH 5.5), while radiopacity, structural stability, mechanical strength, and mass loss are monitored. The polymer matrix determines overall degradation kinetics, which increases with lower pH and higher TaO x content. Importantly, all radiopaque phantoms could be monitored for a full 20 weeks. Phantoms implanted in vivo and serially imaged demonstrate similar results. An optimal range of 5–20 wt% TaO x nanoparticles balances radiopacity requirements with implant properties, facilitating next‐generation biomedical devices.

Subjects

MeSH terms (MEDLINE)

OxidesNanoparticlesPolymersTomography, X-Ray ComputedTantalum

Author keywords

computed tomographydegradationmonitoringnanoparticlesradiopacity

Substances

OxidesPolymerstantalum oxideTantalum

Authors and institutions

  • Department of Radiology, Michigan State University, 846 Service Rd, East Lansing, MI, 48824, USA.
  • Department of Biomedical Engineering, Michigan State University, 775 Woodlot Dr, East Lansing, MI, 48824, USA.
  • Institute for Quantitative Health Science and Engineering (IQ), Michigan State University, 775 Woodlot Dr, East Lansing, MI, 48824, USA.
  • Department of Computational Mathematics Science Engineering, Michigan State University, 428 S. Shaw Ln, East Lansing, MI, 48824, USA.

ORCID profiles: Kendell M Pawelec, Shatadru Chakravarty, Jeremy M L Hix, Erik M Shapiro

Funding

  • NIBIB NIH HHS
  • National Institute of Biomedical Imaging and Bioengineering
  • National Institutes of Health

Cite

APA

Pawelec, K. M., Tu, E., Chakravarty, S., Hix, J. M. L., Buchanan, L., Kenney, L., Buchanan, F., Chatterjee, N., Das, S., Alessio, A., & Shapiro, E. M. (2023). Incorporating Tantalum Oxide Nanoparticles into Implantable Polymeric Biomedical Devices for Radiological Monitoring. Advanced Healthcare Materials, 12(18). https://doi.org/10.1002/adhm.202203167

Vancouver

Pawelec KM, Tu E, Chakravarty S, Hix JML, Buchanan L, Kenney L, et al. Incorporating Tantalum Oxide Nanoparticles into Implantable Polymeric Biomedical Devices for Radiological Monitoring. Advanced Healthcare Materials. 2023;12(18). doi:10.1002/adhm.202203167

BibTeX
@article{Pawelec2023,
  author = {Pawelec, Kendell M and Tu, Ethan and Chakravarty, Shatadru and Hix, Jeremy M L and Buchanan, Lane and Kenney, Legend and Buchanan, Foster and Chatterjee, Nandini and Das, Subhashri and Alessio, Adam and Shapiro, Erik M},
  title = {Incorporating Tantalum Oxide Nanoparticles into Implantable Polymeric Biomedical Devices for Radiological Monitoring},
  journal = {Advanced Healthcare Materials},
  year = {2023},
  volume = {12},
  number = {18},
  doi = {10.1002/adhm.202203167}
}
Start for free →