Highly Stable and Sensitive (PEA) 2 PbBr 4 /CsPbBr 3 Single‐Crystal Heterojunction X‐Ray Detector with Ultra‐Low Detection Limit
Advanced Functional Materials · 2024-08 · 34 (34)
DOI: 10.1002/adfm.202400817 ↗Kurz gefasst
Fachartikel in der Zeitschrift Advanced Functional Materials, online erschienen am 18.04.2024. Verfasst von Zhuangjie Xu und 10 weiteren Autor:innen. Die Arbeit wurde bisher 46-mal zitiert (Crossref) und nennt 55 Literaturangaben. Gefördert von: National Key Research and Development Program of China, National Natural Science Foundation of China, Key Technologies Research and Development Program.
Abstract (Originalsprache)
Metal halide perovskite (MHP) single crystals have shown great potential for high‐performance X‐ray detection due to their excellent carrier transport properties, tunable optical bandgap, and low‐temperature fabrication process. However, 3D perovskite single crystals suffer from severe ion migration, limiting the stability and sensitivity of X‐ray detectors. Herein, a lowing temperature crystallization (LTC) method for liquid‐phase epitaxial growth of 2D (PEA) 2 PbBr 4 single‐crystal (SC) film on 3D CsPbBr 3 substrate is demonstratedand a 2D/3D (PEA) 2 PbBr 4 /CsPbBr 3 SC heterojunction is successfully constructed. The epitaxial (PEA) 2 PbBr 4 layer shows a pronounced passivation effect on CsPbBr 3 SC with a low trap density of 2.27 × 10 10 cm −3 . As such, the prepared 2D/3D heterojunction X‐ray detector achieves a record‐low detectable dose rate of 3.05 nGy air s −1 and high sensitivity of 34496 µC Gy air −1 cm −2 in 120 keV hard X‐ray detection, with a largely suppressed dark current drift of 2.49 × 10 −4 nA cm −1 s −1 V −1 . In addition, the heterojunction detector exhibits a self‐driven sensitivity of 44 µC Gy air −1 cm −2 due to its built‐in electric field. This work provides a simple strategy to controllable construct 2D/3D MHP SC heterojunction with excellent optoelectronic characteristic, which is conducive to promoting the development of MHP SC X‐ray detectors and other optoelectronic devices.
Förderung
- National Key Research and Development Program of China
- National Natural Science Foundation of China
- Key Technologies Research and Development Program
Zitieren
APA
Xu, Z., Xi, H., Sun, X., Liu, H., Liu, J., Ba, Y., Chen, D., Zhang, G., Zhang, C., Ma, X., & Hao, Y. (2024). Highly Stable and Sensitive (PEA) 2 PbBr 4 /CsPbBr 3 Single‐Crystal Heterojunction X‐Ray Detector with Ultra‐Low Detection Limit. Advanced Functional Materials, 34(34). https://doi.org/10.1002/adfm.202400817
Vancouver
Xu Z, Xi H, Sun X, Liu H, Liu J, Ba Y, et al. Highly Stable and Sensitive (PEA) 2 PbBr 4 /CsPbBr 3 Single‐Crystal Heterojunction X‐Ray Detector with Ultra‐Low Detection Limit. Advanced Functional Materials. 2024;34(34). doi:10.1002/adfm.202400817
BibTeX
@article{Xu2024,
author = {Xu, Zhuangjie and Xi, He and Sun, Xue and Liu, Hongjie and Liu, Jiaxin and Ba, Yanshuang and Chen, Dandan and Zhang, Guodong and Zhang, Chunfu and Ma, Xiaohua and Hao, Yue},
title = {Highly Stable and Sensitive (PEA) 2 PbBr 4 /CsPbBr 3 Single‐Crystal Heterojunction X‐Ray Detector with Ultra‐Low Detection Limit},
journal = {Advanced Functional Materials},
year = {2024},
volume = {34},
number = {34},
doi = {10.1002/adfm.202400817}
}