EUVIMEDEUVIMED entdecken
Crossref

Sintered Polycrystalline BiVO 4 Pellet for Stable X‐Ray Detector with Low Detection Limit

Shanshan Jia, Yingrui Xiao, Nuo Bu, Nan Li, Deng Li, Zhou Yang, Shengzhong (Frank) Liu

Advanced Functional Materials · 2023-04 · 33 (16)

DOI: 10.1002/adfm.202213563 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Advanced Functional Materials, online erschienen am 08.02.2023. Verfasst von Shanshan Jia und 6 weiteren Autor:innen. Die Arbeit wurde bisher 19-mal zitiert (Crossref) und nennt 41 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Shaanxi Normal University, Higher Education Discipline Innovation Project.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Semiconductors based on Bi element show large attenuation coefficients to X‐ray photons and have been recognized as candidates for X‐ray detectors. However, the application of stable Bi‐based oxide materials to X‐ray detectors has been rarely investigated. In this research, the X‐ray response of a BiVO 4 pellet has been studied. It has been found that the BiVO 4 pellet has a large resistivity of 1.3 × 10 12 Ω cm, negligible current drift of 6.18 × 10 −8 nA cm −1 s −1 V −1 under electrical bias and mobility lifetime product, µτ , of 1.75 × 10 −4 cm 2 V −1 , which renders the pellet with an X‐ray sensitivity of 241.3 µC Gy air −1 cm −2 and a detection limit of 62 nGy air s −1 under 40 KVp X‐ray illumination and 40 V bias voltage. The BiVO 4 pellet also shows operational stability under steady X‐ray illumination with total dose of 2.01 Gy air , equal to the dose of 20 000 medical chest X‐ray inspections. This research reveals the potential application of BiVO 4 in X‐ray detection devices and inspires further research in this area.

Förderung

  • National Natural Science Foundation of China
  • Shaanxi Normal University
  • Higher Education Discipline Innovation Project

Zitieren

APA

Jia, S., Xiao, Y., Bu, N., Li, N., Li, D., Yang, Z., & Liu, S. F. (2023). Sintered Polycrystalline BiVO 4 Pellet for Stable X‐Ray Detector with Low Detection Limit. Advanced Functional Materials, 33(16). https://doi.org/10.1002/adfm.202213563

Vancouver

Jia S, Xiao Y, Bu N, Li N, Li D, Yang Z, et al. Sintered Polycrystalline BiVO 4 Pellet for Stable X‐Ray Detector with Low Detection Limit. Advanced Functional Materials. 2023;33(16). doi:10.1002/adfm.202213563

BibTeX
@article{Jia2023,
  author = {Jia, Shanshan and Xiao, Yingrui and Bu, Nuo and Li, Nan and Li, Deng and Yang, Zhou and Liu, Shengzhong (Frank)},
  title = {Sintered Polycrystalline BiVO 4 Pellet for Stable X‐Ray Detector with Low Detection Limit},
  journal = {Advanced Functional Materials},
  year = {2023},
  volume = {33},
  number = {16},
  doi = {10.1002/adfm.202213563}
}
Kostenlos starten →