The Influence of Design Modifications and Microstructured Surface Topographies on Bleb Survival after Glaucoma Tube Shunt Implantation
Advanced Biology · 2023
DOI: 10.1002/adbi.202300051 ↗Kurz gefasst
Fachartikel in der Zeitschrift Advanced Biology, 2023. Verfasst von Ralph J S van Mechelen und 7 weiteren Autor:innen. Beteiligte Einrichtung: University Eye Clinic Maastricht, Maastricht University Medical Center+ (MUMC+), 6202 AZ, Maastricht, The Netherlands. Hauptthemen laut MEDLINE: Glaucoma Drainage Implants, Glaucoma. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Lowering intraocular pressure (IOP) by placement of a glaucoma shunt is an effective treatment for glaucoma. However, fibrosis of the outflow site can hamper surgical outcome. In this study, the antifibrotic effect of adding an endplate (with or without microstructured surface topographies) to a microshunt made of poly(styrene‐block‐isobutylene‐block‐styrene) is investigated. New Zealand white rabbits are implanted with a control implant (without endplate) and modified implants. Afterward, bleb morphology and IOP is recorded for 30 days. After killing of the animals, eyes are collected for histology, Addition of an endplate extended bleb survival, Topography‐990 has the longest recorded bleb‐survival time. Histology reveals that the addition of an endplate increases the presence of myofibroblasts, macrophages, polymorphonuclear cells, and foreign body giant cells compared to the control. However, an increased capsule thickness and inflammatory response are observed in the groups with surface topographies, The addition of an endplate results in prolonged bleb survival, demonstrating that engineering of the shape of glaucoma implants could prolong bleb functionality. Future research should further elaborate the effect of surface topographies on long‐term bleb survival, since an increased presence of pro‐fibrotic cells and increased capsule thickness are observed compared to the control.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- University Eye Clinic Maastricht, Maastricht University Medical Center+ (MUMC+), 6202 AZ, Maastricht, The Netherlands.
- School for Mental Health and Neuroscience, Maastricht University, 6229 ER, Maastricht, The Netherlands.
- Department of Biomedical Engineering and Institute for Complex Molecular Systems, Eindhoven University of Technology, 5612 AZ, Eindhoven, The Netherlands.
- Department of Medical Biochemistry, Experimental Vascular Biology, Amsterdam Cardiovascular Sciences, Amsterdam Infection and Immunity, Amsterdam UMC, Meibergdreef 9, 1105 AZ, Amsterdam, Netherlands.
- InnFocus Inc. a Santen company, 12415 S.W. 136 avenue, Miami, FL, 33186, USA.
ORCID-Profile: Ralph J S van Mechelen
Zitieren
APA
van Mechelen, R. J. S., Sudarsanam, P., Bertens, C. J. F., Tas, M. O., Gijbels, M. J. J., Pinchuk, L., de Boer, J., & Beckers, H. J. M. (2023). The Influence of Design Modifications and Microstructured Surface Topographies on Bleb Survival after Glaucoma Tube Shunt Implantation. Advanced Biology. https://doi.org/10.1002/adbi.202300051
Vancouver
van Mechelen RJS, Sudarsanam P, Bertens CJF, Tas MO, Gijbels MJJ, Pinchuk L, et al. The Influence of Design Modifications and Microstructured Surface Topographies on Bleb Survival after Glaucoma Tube Shunt Implantation. Advanced Biology. 2023. doi:10.1002/adbi.202300051
BibTeX
@article{vanMechelen2023,
author = {van Mechelen, Ralph J S and Sudarsanam, Phani and Bertens, Christian J F and Tas, Mehmet O and Gijbels, Marion J J and Pinchuk, Leonard and de Boer, Jan and Beckers, Henny J M},
title = {The Influence of Design Modifications and Microstructured Surface Topographies on Bleb Survival after Glaucoma Tube Shunt Implantation},
journal = {Advanced Biology},
year = {2023},
doi = {10.1002/adbi.202300051}
}
EUVIMED