Attention Xception U‐Net (AXUNet): An explainable combination of CNN and self‐attention for reliable glioma segmentation in MRI
Journal of Applied Clinical Medical Physics · 2026-11 · 27 (11)
DOI: 10.1002/acm2.70902 ↗At a glance
Journal article in Journal of Applied Clinical Medical Physics, published online on 2026-11-13. Written by Farzan Moodi and 6 co-authors. Institution: Quantitative MR Imaging and Spectroscopy Group (QMISG), Tehran University of Medical Sciences, Tehran, Iran. Major MEDLINE topics: Glioma, Brain Neoplasms, Magnetic Resonance Imaging, Image Processing, Computer-Assisted. 40 references. The full text is freely available (open access, CC BY 4.0).
Abstract (original language)
Background
Gliomas are the most common primary malignant brain tumors and exhibit highly heterogeneous morphology and infiltrative growth patterns. Accurate delineation of tumor subregions in magnetic resonance imaging (MRI) is therefore critical for diagnosis, treatment planning, and longitudinal monitoring, yet manual segmentation remains time‐consuming and subject to inter‐observer variability.
Purpose
Accurate glioma segmentation in magnetic resonance imaging (MRI) is essential for diagnosis, treatment planning, and reproducible tumor delineation. However, for clinical adoption, automated segmentation systems must provide not only high accuracy but also robustness and interpretability. This study aimed to develop an explainable and reliable deep learning framework for glioma segmentation and to evaluate its performance on both internal and external datasets.
Method
We used the BraTS 2021 training dataset, which contains 1251 multi‐institutional pre‐operative glioma MRI cases. After comparing multiple sequence combinations, T1ce, T2, and Fluid Attenuated Inversion Recovery (FLAIR) were selected as the final three‐channel input. Preprocessing included tumor‐oriented slice selection, cropping, Min‐Max normalization, and augmentation. We developed AXUNet, a UNet‐based architecture that integrates memory‐efficient Xception blocks with a self‐attention module combining kernel‐based pixel attention and dot‐product channel attention. Internal ablation analysis and Gradient‐weighted Class Activation Mapping (Grad‐CAM)‐based visualization were also performed.
Results
On the BraTS 2021 test partition, AXUNet achieved the highest mean Dice score (93.73), outperforming UNet (93.26), Inception‐UNet (90.88), Attention Gate UNet (AG‐UNet) (90.38), Attention ResUNet (AResUNet) (92.80), and Xception‐UNet (93.24). Region‐wise Dice scores were 92.59 for Whole Tumor (WT), 86.81 for Tumor Core (TC), and 84.89 for Enhancing tumor (ET). Although AResUNet achieved a slightly higher ET score (84.92), AXUNet demonstrated the strongest performance in mean Dice, WT, and TC. To further assess generalizability, AXUNet was independently evaluated on 219 previously unseen BraTS 2023 cases through the Synapse platform, achieving Dice scores of 86.29% for WT, 78.53% for TC, and 69.00% for ET.
Conclusion
AXUNet demonstrates that combining Xception‐based encoding with self‐attention can improve glioma segmentation while also supporting explainability and external robustness, positioning it as a promising framework for MRI‐based glioma segmentation. Its clinical relevance, and the practical value of its interpretability outputs, remain to be established through further, dedicated validation beyond Dice‐based benchmarking.
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- Quantitative MR Imaging and Spectroscopy Group (QMISG), Tehran University of Medical Sciences, Tehran, Iran.
- Department of Radiology, Shariati Hospital, Tehran University of Medical Sciences, Tehran, Iran.
- Nuclear Engineering Department, Shiraz University, Shiraz, Iran.
- Radiation Research Center, Shiraz University, Shiraz, Iran.
- Department of Medical Physics and Biomedical Engineering, Tehran University of Medical Sciences, Tehran, Iran.
Cite
APA
Moodi, F., Khodadadi Shoushtari, F., Valizadeh, G., Mazinani, D., Mobarak Salari, H., Sina, S., & Saligheh Rad, H. (2026). Attention Xception U‐Net (AXUNet): An explainable combination of CNN and self‐attention for reliable glioma segmentation in MRI. Journal of Applied Clinical Medical Physics, 27(11). https://doi.org/10.1002/acm2.70902
Vancouver
Moodi F, Khodadadi Shoushtari F, Valizadeh G, Mazinani D, Mobarak Salari H, Sina S, et al. Attention Xception U‐Net (AXUNet): An explainable combination of CNN and self‐attention for reliable glioma segmentation in MRI. Journal of Applied Clinical Medical Physics. 2026;27(11). doi:10.1002/acm2.70902
BibTeX
@article{Moodi2026,
author = {Moodi, Farzan and Khodadadi Shoushtari, Fereshteh and Valizadeh, Gelareh and Mazinani, Dornaz and Mobarak Salari, Hanieh and Sina, Sedigheh and Saligheh Rad, Hamidreza},
title = {Attention Xception U‐Net (AXUNet): An explainable combination of CNN and self‐attention for reliable glioma segmentation in MRI},
journal = {Journal of Applied Clinical Medical Physics},
year = {2026},
volume = {27},
number = {11},
doi = {10.1002/acm2.70902}
}
EUVIMED