Fachartikel in der Zeitschrift Journal of Applied Clinical Medical Physics, 2026-11. Verfasst von Andreas Havsgård Handeland und 6 weiteren Autor:innen. Beteiligte Einrichtung: Cancer Clinic, Haukeland University Hospital, Bergen, Norway. Hauptthemen laut MEDLINE: Proton Therapy, Radiotherapy Planning, Computer-Assisted, Radiotherapy, Intensity-Modulated, Rhabdomyosarcoma. Die Arbeit nennt 55 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Helse Vest, Research Council of Norway, Norwegian Cancer Society.
Abstract (Originalsprache)
Background
Parameningeal rhabdomyosarcomas (PM‐RMS) are pediatric tumors with a high risk of local failure and severe toxicity. Intensity modulated proton therapy (IMPT) offers improved healthy tissue sparing compared to conventional photon‐based radiotherapy, and proton arc therapy (PAT) might offer further improvement in healthy tissue sparing for these patients, thus emphasizing the need for systematic studies specifically focusing on PM‐RMS patients. Additionally, the relative biological effectiveness (RBE) of protons is known to vary with linear energy transfer (LET).
Purpose
The aim of this study was to investigate the potential of LET‐optimized PAT for PM‐RMS treatment.
Methods
Volumetric modulated arc therapy (VMAT) plans, IMPT and PAT plans, both with and without LET optimization were made for 13 PM‐RMS patients using Raystation version 2023B. The plans were evaluated based on the achievement of clinical goals, homogeneity index, delivery time, robustness, LET and variable RBE‐weighted dose within the target and selected OARs.
Results
LET optimization increased the mean LET in the target from 2.5 keV/µm [2.1, 2.8] to 3.4 keV/µm [2.7, 4.1] for IMPT and from 2.8 keV/µm [2.5, 3.1] to 3.4 keV/µm [2.7, 4.0] for PAT with minor changes in dose distributions. Target coverage and OAR doses were comparable between IMPT and PAT, while both had an expected improvement in OAR sparing compared to VMAT. Delivery times were 134.5 [95.3, 203.7] seconds for the IMPT plans and 197.4 [138.9, 244.6] seconds for the PAT plans before LET optimization, and were for both modalities reduced by around 2–5 seconds after LET optimization.
Conclusions
The dose distribution was similar across PAT and IMPT in this study, and superior compared to VMAT. LET optimization in the proton plans achieved LET improvements in both target and OARs without compromising dose.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Cancer Clinic, Haukeland University Hospital, Bergen, Norway.
- Department of Physics and Technology, University of Bergen, Bergen, Norway.
- Department of Radiation Oncology, University of Florida College of Medicine, Jacksonville, Florida, USA.
- University of Florida Health Proton Therapy Institute, Jacksonville, Florida, USA.
ORCID-Profile: Andreas Havsgård Handeland
Förderung
- Helse Vest
- Research Council of Norway
- Norwegian Cancer Society
- Norges Forskningsråd
- Kreftforeningen
Zitieren
APA
Handeland, A. H., Grewal, H. S., Boer, C. G., Indelicato, D. J., Ytre-Hauge, K. S., Henjum, H., & Stokkevåg, C. H. (2026). Dynamic Proton arc therapy for paediatric parameningeal rhabdomyosarcoma. Journal of Applied Clinical Medical Physics. https://doi.org/10.1002/acm2.70867
Vancouver
Handeland AH, Grewal HS, Boer CG, Indelicato DJ, Ytre-Hauge KS, Henjum H, et al. Dynamic Proton arc therapy for paediatric parameningeal rhabdomyosarcoma. Journal of Applied Clinical Medical Physics. 2026. doi:10.1002/acm2.70867
BibTeX
@article{Handeland2026,
author = {Handeland, Andreas Havsgård and Grewal, Hardev Singh and Boer, Camilla Grindeland and Indelicato, Daniel J and Ytre-Hauge, Kristian Smeland and Henjum, Helge and Stokkevåg, Camilla Hanquist},
title = {Dynamic Proton arc therapy for paediatric parameningeal rhabdomyosarcoma},
journal = {Journal of Applied Clinical Medical Physics},
year = {2026},
doi = {10.1002/acm2.70867}
}
EUVIMED