EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Correlation of size specific dose estimates with organ dose in abdominal spectral computed tomography

Tian Qin, Qingting Sun iD, Yihan Fan, Mengting Wang, Jing Wang, Yankui Chang iD, Baohui Liang

Journal of Applied Clinical Medical Physics · 2026

DOI: 10.1002/acm2.70845 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Applied Clinical Medical Physics, 2026. Verfasst von Tian Qin und 6 weiteren Autor:innen. Beteiligte Einrichtung: Division of Life Sciences and Medicine, The First Affiliated Hospital of USTC, University of Science and Technology of China, Hefei, Anhui, China. Hauptthemen laut MEDLINE: Tomography, X-Ray Computed, Monte Carlo Method, Organs at Risk, Radiography, Abdominal. Die Arbeit nennt 44 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

In abdominal spectral Computed Tomography (CT), organ dose assessment is important for radiation safety but remains challenging due to the complexity of Monte Carlo (MC) simulations.

Purpose

This study aimed to compare the correlations of three size‐specific dose estimate (SSDE) metrics (including the central slice SSDE center , the mean of all slices SSDE mean , and the organ‐specific SSDE organ ) with organ doses and to establish a rapid estimation method for organ dose using linear regression in abdominal spectral CT.

Methods

Monte Carlo N‐Particle (MCNP6) was used to model the General Electric (GE) Revolution CT scanner, including its bowtie filter, radiation source, and simulations of tube voltage switching and the X‐ray tube trajectory. Digital Imaging and Communications in Medicine (DICOM) data from 30 patients undergoing abdominal spectral CT with identical scan parameters were processed using 3D Slicer. Radiation‐sensitive organs were delineated. Following this, digital models were constructed and subsequently voxelized. All patient external body contours were delineated using ImageJ software. Three SSDE metrics were calculated for all patients. Linear regression analysis was performed to correlate organ doses with the three SSDE metrics and to derive estimation coefficients.

Results

The results indicated that in abdominal spectral CT examinations on a Revolution scanner, SSDE organ exhibited the strongest correlation with organ dose. The R 2 values for the liver, stomach, pancreas, spleen, kidneys, spinal cord, and bladder were 0.89, 0.61, 0.81, 0.85, 0.88, 0.94, and 0.68, respectively. The corresponding estimation coefficients derived from SSDE organ for these organs were 0.42, 0.36, 0.37, 0.41, 0.36, 0.26, and 0.26, respectively. The estimation errors for the conversion coefficient combined with SSDE organ , relative to the MC simulation results, were 7.34% for the liver, 6.09% for the kidneys, 13.25% for the spleen, 2.97% for the spinal cord, 13.61% for the pancreas, 17.64% for the stomach, and 18.56% for the bladder.

Conclusions

For abdominal spectral CT, SSDE organ demonstrated the strongest correlation with individual organ doses. These findings enable rapid and accurate estimation of organ dose, providing a basis for personalized radiation dose assessment in clinical practice.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tomography, X-Ray ComputedMonte Carlo MethodOrgans at RiskRadiography, AbdominalImage Processing, Computer-AssistedRadiotherapy Planning, Computer-AssistedPhantoms, ImagingHumansRadiation DosageFemaleMaleRadiotherapy, Intensity-Modulated

Stichwörter der Autor:innen

Monte Carlocomputed tomographyorgan dosesize‐specific dose estimatespectral CT

Autor:innen und Institutionen

  • Division of Life Sciences and Medicine, The First Affiliated Hospital of USTC, University of Science and Technology of China, Hefei, Anhui, China.
  • School of Medical Imaging, Bengbu Medical University, Bengbu, Anhui, China.
  • Department of Oncology, The Second Hospital of Anhui Medical University, Hefei, Anhui, China.
  • Department of Radiology, The First Affiliated Hospital of Bengbu Medical University, Bengbu, Anhui, China.
  • Anhui Key Laboratory of Digital Medicine and Intelligent Health, Bengbu Medical University, Bengbu, Anhui, China.

ORCID-Profile: Qingting Sun, Yankui Chang

Zitieren

APA

Qin, T., Sun, Q., Fan, Y., Wang, M., Wang, J., Chang, Y., & Liang, B. (2026). Correlation of size specific dose estimates with organ dose in abdominal spectral computed tomography. Journal of Applied Clinical Medical Physics. https://doi.org/10.1002/acm2.70845

Vancouver

Qin T, Sun Q, Fan Y, Wang M, Wang J, Chang Y, et al. Correlation of size specific dose estimates with organ dose in abdominal spectral computed tomography. Journal of Applied Clinical Medical Physics. 2026. doi:10.1002/acm2.70845

BibTeX
@article{Qin2026,
  author = {Qin, Tian and Sun, Qingting and Fan, Yihan and Wang, Mengting and Wang, Jing and Chang, Yankui and Liang, Baohui},
  title = {Correlation of size specific dose estimates with organ dose in abdominal spectral computed tomography},
  journal = {Journal of Applied Clinical Medical Physics},
  year = {2026},
  doi = {10.1002/acm2.70845}
}
Kostenlos starten →