Outcomes and comparison of dosimetric parameters between intracavitary (Fletcher) and combined intracavitary/interstitial (Utrecht) brachytherapy in locally advanced cervical cancer
Brachytherapy · 2024
DOI: 10.1016/j.brachy.2023.09.004 ↗Kurz gefasst
Fachartikel in der Zeitschrift Brachytherapy, 2024. Verfasst von Kashif Ali Sarwar und 5 weiteren Autor:innen. Beteiligte Einrichtung: Combined Military Hospital, National University of Medical Sciences (NUMS), Rawalpindi, Pakistan. Electronic address: kashifsarwar11@gmail.com. Hauptthemen laut MEDLINE: Uterine Cervical Neoplasms, Brachytherapy. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 23 Literaturangaben.
Abstract (Originalsprache)
OBJECTIVE: To report outcomes of combined intracavitary/interstitial (IC/IS) image-guided brachytherapy (IGBT) in locally advanced cervical cancer, and to compare its dosimetric parameters with intracavitary-only (IC) brachytherapy in a first-in-country experience. METHODS AND MATERIALS: Between January 2021 and September 2022, a total of 160 insertions were done in 40 patients with FIGO IB3-IVA cervical cancer undergoing IGBT using a hybrid (Utrecht) applicator. Corresponding treatment plans for IC brachytherapy were generated during treatment, and optimized. A preplanned comparison of dosimetric parameters, defined in GEC-ESTRO was conducted. RESULTS: The clinical use of a hybrid IC/IS applicator was feasible in all insertions. An average of 14 needles were inserted in each patient over four fractions. Mean HR-CTV D90 and D98 was 86 (SD 1.9) Gy and 75.7 (SD 2.3) Gy using hybrid applicator, and 80 (SD 5.4) Gy and 69.8 (SD 5.2) Gy using IC applicator, with a mean dose gain of 6.0 (SD 5.0) Gy and 5.9 (SD 4.7) Gy (p
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Combined Military Hospital, National University of Medical Sciences (NUMS), Rawalpindi, Pakistan. Electronic address: kashifsarwar11@gmail.com.
- Combined Military Hospital, National University of Medical Sciences (NUMS), Rawalpindi, Pakistan.
Zitieren
APA
Sarwar, K. A., Hussain, S., Syed, A. S., Khan, K., Maqsood, T., & Azeem, T. (2024). Outcomes and comparison of dosimetric parameters between intracavitary (Fletcher) and combined intracavitary/interstitial (Utrecht) brachytherapy in locally advanced cervical cancer. Brachytherapy. https://doi.org/10.1016/j.brachy.2023.09.004
Vancouver
Sarwar KA, Hussain S, Syed AS, Khan K, Maqsood T, Azeem T. Outcomes and comparison of dosimetric parameters between intracavitary (Fletcher) and combined intracavitary/interstitial (Utrecht) brachytherapy in locally advanced cervical cancer. Brachytherapy. 2024. doi:10.1016/j.brachy.2023.09.004
BibTeX
@article{Sarwar2024,
author = {Sarwar, Kashif Ali and Hussain, Sameed and Syed, Abdus Samad and Khan, Khurram and Maqsood, Talha and Azeem, Tariq},
title = {Outcomes and comparison of dosimetric parameters between intracavitary (Fletcher) and combined intracavitary/interstitial (Utrecht) brachytherapy in locally advanced cervical cancer},
journal = {Brachytherapy},
year = {2024},
doi = {10.1016/j.brachy.2023.09.004}
}