EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Deriving target exposure indices for common radiography exams based on automatic exposures of flat‐field phantoms

Matthew Hoerner iD, Emily L Marshall iD, Katie Hulme iD, Ashley Tao, Suha Alshehri, Shady AlKhazzam, Zaiyang Long iD, Erin Macdonald, Kathleen Scilla, Ioannis Tsalafoutas

Journal of Applied Clinical Medical Physics · 2026

DOI: 10.1002/acm2.70562 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Applied Clinical Medical Physics, 2026. Verfasst von Matthew Hoerner und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Yale New Haven Health, New Haven, CT, USA. Hauptthemen laut MEDLINE: Phantoms, Imaging, Image Processing, Computer-Assisted, Algorithms, Quality Assurance, Health Care. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 13 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

The IEC exposure index (EI), deviation index (DI), and target exposure index (EI T ), represent critical standardized metrics for the evaluation of exposure and quality in radiographic imaging.

Purpose

This work develops and validates a systematic procedure to estimate the EI T for eight of the most common radiography imaging protocols utilizing automatic exposure control (AEC) from measurements acquired under reference conditions.

Methods

A model was developed to define the relationship between a systems AEC logic, and an estimation of the EI under flat‐field conditions (EIFFC). Separately, clinical data and acquisition protocol information for resultant EI during patient studies were also collected for the eight protocols studied: Chest posteroanterior (PA), Chest lateral, Abdomen anteroposterior (AP), Pelvis AP, L‐Spine AP, C‐Spine AP, T‐Spine AP, and Ribs AP. Data were collected from 41 x‐ray units spanning seven institutions. For each protocol on each unit the EIFFC was computed based on the acquisition protocol, as well as median EI from clinical exams to produce a scaling factor (SF). Kruskal–Wallis statistical tests were used to compare SF's between vendors and AEC cell configurations.

Results

SFs for eight radiographic imaging protocols have been produced per vendor and per AEC cell selection. A workflow has been established for end‐users to follow to apply these SFs to flat‐field measurements taken at their own locations to establish local EI T .

Conclusions

The study results show that in seven of the eight imaging protocols, the SFs for most units included in the study report SFs within 1 DI (± 25%) of their respective final vendor reported SF (218/228). The ribs protocol is the exception to this finding (n = 26). SFs have high utility for establishing EI T values on individual x‐ray units and normalizing EI value distributions for quality assurance purposes.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Phantoms, ImagingImage Processing, Computer-AssistedAlgorithmsQuality Assurance, Health CareHumansRadiation Dosage

Stichwörter der Autor:innen

automatic exposure controldeviation indexdigital radiographyquality controlradiographytarget exposure index

Autor:innen und Institutionen

  • Department of Radiology, Yale New Haven Health, New Haven, CT, USA.
  • Department of Radiology, University of Florida, Gainesville, FL, USA.
  • Department of Radiology, Cleveland Clinic, Cleveland, OH, USA.
  • Department of Radiology, Emplify Health by Gundersen, La Crosse, WI, USA.
  • Hamad Medical Corporation, Doha, Qatar.
  • Department of Radiology, Mayo Clinic, Rochester, MN, USA.

ORCID-Profile: Matthew Hoerner, Emily L Marshall, Katie Hulme, Zaiyang Long

Zitieren

APA

Hoerner, M., Marshall, E. L., Hulme, K., Tao, A., Alshehri, S., AlKhazzam, S., Long, Z., Macdonald, E., Scilla, K., & Tsalafoutas, I. (2026). Deriving target exposure indices for common radiography exams based on automatic exposures of flat‐field phantoms. Journal of Applied Clinical Medical Physics. https://doi.org/10.1002/acm2.70562

Vancouver

Hoerner M, Marshall EL, Hulme K, Tao A, Alshehri S, AlKhazzam S, et al. Deriving target exposure indices for common radiography exams based on automatic exposures of flat‐field phantoms. Journal of Applied Clinical Medical Physics. 2026. doi:10.1002/acm2.70562

BibTeX
@article{Hoerner2026,
  author = {Hoerner, Matthew and Marshall, Emily L and Hulme, Katie and Tao, Ashley and Alshehri, Suha and AlKhazzam, Shady and Long, Zaiyang and Macdonald, Erin and Scilla, Kathleen and Tsalafoutas, Ioannis},
  title = {Deriving target exposure indices for common radiography exams based on automatic exposures of flat‐field phantoms},
  journal = {Journal of Applied Clinical Medical Physics},
  year = {2026},
  doi = {10.1002/acm2.70562}
}
Kostenlos starten →