Isocenter Optimization in WBRT: Concurrent Sparing of Lens and Lacrimal Gland via Anterior Penumbra Sharpening
Journal of Applied Clinical Medical Physics · 2026-03 · 27 (3)
DOI: 10.1002/acm2.70535 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Applied Clinical Medical Physics, online erschienen am 18.03.2026. Verfasst von Chen Xie und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Oncology, Luzhou People's Hospital, Luzhou, Sichuan, China. Hauptthemen laut MEDLINE: Lacrimal Apparatus, Radiotherapy Planning, Computer-Assisted, Organs at Risk, Lens, Crystalline. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 59 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
With improving survival for patients receiving whole‐brain radiotherapy (WBRT), mitigating long‐term toxicities like cataract and dry eye syndrome has become increasingly critical. The lens and lacrimal gland are highly radiosensitive and lie in close proximity to the target volume, posing a persistent challenge for achieving sharp dose gradients. While modern techniques like multileaf collimator (MLC) shaping offer some protection, the potential of classic geometric optimization principles, such as anterior beam shift, remains underexplored in contemporary treatment planning workflows.
Purpose
This study aimed to systematically translate, quantitatively validate, and integrate the classic geometric principle of anterior isocenter shift into the modern treatment planning workflow for the dual protection of the lens and lacrimal gland in WBRT, utilizing 3D‐conformal radiotherapy (3D‐CRT) and field‐in‐field (FIF) techniques.
Methods
For 40 patients, conventional and isocenter‐optimized plans (involving an anterior shift of the isocenter within the PTV) were generated for both 3D‐CRT and FIF. We compared dosimetric parameters for the planning target volume (PTV), lenses, lacrimal glands, and other organs at risk. Plan quality, normal tissue complication probability (NTCP) for cataract and dry eye syndrome, and clinical risk stratification were evaluated Results Isocenter optimization significantly reduced the median lens Dmax by 20% and PRV_lens D0.03 cm3 by 23% ( p < 0.001). Lacrimal gland Dmean, V6Gy, and V10Gy were also significantly reduced. The strategy physically improved the dose gradient, narrowing the penumbra width by 31.25% and increasing the dose fall‐off rate by 15%, while reducing low‐dose irradiation volumes outside the PTV. These dosimetric benefits translated into meaningful reductions in projected NTCP for both complications. The 3D‐FIF plans maintained target coverage and homogeneity, mitigating the heterogeneity increase observed in 3D‐CRT plans.
Conclusion
Anterior isocenter optimization is a practical, and hardware‐free technique that seamlessly synergizes with modern MLC‐based planning to provide significant, concurrent sparing of the lens and lacrimal gland in WBRT. As a readily implementable modification within existing planning systems, this strategy can be adopted immediately to enhance treatment safety without requiring additional resources.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Oncology, Luzhou People's Hospital, Luzhou, Sichuan, China.
- Department of Plastic and Burn Surgery, The Affiliated Hospital of Southwest Medical University, Luzhou, Sichuan, China.
- Department of Oncology, The Affiliated Hospital of Southwest Medical University, Luzhou, Sichuan, China.
ORCID-Profile: Chen Xie, Haowen Pang
Zitieren
APA
Xie, C., Xia, X., Pang, H., Zhang, Y., Li, L., & Lu, S. (2026). Isocenter Optimization in WBRT: Concurrent Sparing of Lens and Lacrimal Gland via Anterior Penumbra Sharpening. Journal of Applied Clinical Medical Physics, 27(3). https://doi.org/10.1002/acm2.70535
Vancouver
Xie C, Xia X, Pang H, Zhang Y, Li L, Lu S. Isocenter Optimization in WBRT: Concurrent Sparing of Lens and Lacrimal Gland via Anterior Penumbra Sharpening. Journal of Applied Clinical Medical Physics. 2026;27(3). doi:10.1002/acm2.70535
BibTeX
@article{Xie2026,
author = {Xie, Chen and Xia, Xuemei and Pang, Haowen and Zhang, Yan and Li, Lin and Lu, Simin},
title = {Isocenter Optimization in WBRT: Concurrent Sparing of Lens and Lacrimal Gland via Anterior Penumbra Sharpening},
journal = {Journal of Applied Clinical Medical Physics},
year = {2026},
volume = {27},
number = {3},
doi = {10.1002/acm2.70535}
}
EUVIMED