Dosimetric comparison of coplanar and noncoplanar volumetric modulated arc therapy for hippocampal-sparing whole-brain radiation therapy
Medical Dosimetry · 2024
DOI: 10.1016/j.meddos.2023.08.010 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Medical Dosimetry, 2024. Verfasst von Bo Yang und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, Chinese Academy of Medical Sciences, Peking Union Medical College Hospital, Beijing, China. Hauptthemen laut MEDLINE: Radiotherapy, Intensity-Modulated, Hippocampus, Brain Neoplasms, Radiotherapy Planning, Computer-Assisted. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 29 Literaturangaben.
Abstract (Originalsprache)
Whole brain radiation therapy with hippocampal-sparing (HS-WBRT) is a novel treatment of brain metastases, which can relieve symptoms reduce recurrence in the central nervous system, and spare the hippocampus without compromising target coverage. This study aims to find out the superior combination of the treatment planning system and linear accelerator between Eclipse (version 15.6) with TrueBeam and uRT-TPOIS (vision R001.4) with uRT-linac 506c in HS-WBRT. The coplanar and noncoplanar volumetric modulated arc therapy (VMAT) for HS-WBRT plans were evaluated and compared on both combinations, respectively. Twenty patients for HS-WBRT were retrospectively selected at Peking Union Medical College Hospital (PUMCH) from 2021 to 2022. The coplanar and noncoplanar HS-WBRT treatment plans were designed by Eclipse and uRT-TPOIS referring to RTOG 0933 dose criteria, and their dosimetry parameters were compared. In addition, the plan complexity, monitor units, and beam-on time were recorded for Eclipse plans delivered on TrueBeam and uRT-TPOIS plans delivered on uRT-linac 506c. The results demonstrated that the dosimetric criteria of 4 types of HS-WBRT plans could meet the requirements of RTOG 0933. In terms of target coverage, dosimetric indexes of Eclipse plans and uRT-TPOIS plans were comparable, and the former is slightly better. As for metrics of organs-at-risk protection, coplanar and noncoplanar plans conducted by uRT-TPOIS were greatly superior to those by Eclipse. For coplanar and noncoplanar plans designed by the same treatment planning system, most of the dosimetric indexes had no significant difference. The monitor units of uRT-TPOIS plans was higher than that of Eclipse plans, but the modulation complexity of them were close, and uRT-TPOIS with uRT-linac 506c significantly reduced beam-on-time consumption by 9% on average for coplanar plans and 26% for noncoplanar plans compared to Eclipse with TrueBeam. This study firstly compared the coplanar and noncoplanar HS-WBRT treatment plans between Eclipse with TrueBeam and uRT-TPOIS with uRT-linac 506c in terms of dosimetry indexes, modulation complexity, and time consumption. It is shown that the radiation treatment solution of uRT-TPOIS with uRT-linac 506c is comparable with Eclipse with TrueBeam in terms of planning design, and significantly reduced the delivery time, which can be applied in clinical practice and promoted as a treatment format.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiation Oncology, Chinese Academy of Medical Sciences, Peking Union Medical College Hospital, Beijing, China.
- United Imaging Research Institute of Intelligent Imaging, Beijing, 100094, China.
- United Imaging Research Institute of Innovative Medical Equipment, Shenzhen, 518045, China.
- Shanghai United Imaging Healthcare Co., Ltd., Shanghai, 201807, China.
- Department of Radiation Oncology, Chinese Academy of Medical Sciences, Peking Union Medical College Hospital, Beijing, China. Electronic address: qj_ww@139.com.
Zitieren
APA
Yang, B., Liang, Y., He, S., Liu, Y., Zhang, K., & Qiu, J. (2024). Dosimetric comparison of coplanar and noncoplanar volumetric modulated arc therapy for hippocampal-sparing whole-brain radiation therapy. Medical Dosimetry. https://doi.org/10.1016/j.meddos.2023.08.010
Vancouver
Yang B, Liang Y, He S, Liu Y, Zhang K, Qiu J. Dosimetric comparison of coplanar and noncoplanar volumetric modulated arc therapy for hippocampal-sparing whole-brain radiation therapy. Medical Dosimetry. 2024. doi:10.1016/j.meddos.2023.08.010
BibTeX
@article{Yang2024,
author = {Yang, Bo and Liang, Yongguang and He, Shumeng and Liu, Yinglong and Zhang, Kang and Qiu, Jie},
title = {Dosimetric comparison of coplanar and noncoplanar volumetric modulated arc therapy for hippocampal-sparing whole-brain radiation therapy},
journal = {Medical Dosimetry},
year = {2024},
doi = {10.1016/j.meddos.2023.08.010}
}
EUVIMED