EUVIMEDEUVIMED entdecken
EvaluationsstudieOpen Access · CC BY 4.0

Quantitative evaluation of a deep learning‐based noise reduction algorithm in digital radiography using noise power spectrum analysis

Sho Maruyama iD, Hiroki Saitou

Journal of Applied Clinical Medical Physics · 2026-03 · 27 (3)

DOI: 10.1002/acm2.70521 ↗

Kurz gefasst

Evaluationsstudie in der Zeitschrift Journal of Applied Clinical Medical Physics, online erschienen am 25.02.2026. Verfasst von Sho Maruyama und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiological Technology, Gunma Prefectural College of Health Sciences, Maebashi, Gunma, Japan. Hauptthemen laut MEDLINE: Deep Learning, Radiographic Image Enhancement, Algorithms, Signal-To-Noise Ratio. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 45 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Recently, deep learning (DL)‐based noise reduction (DLNR) has been introduced in clinically used digital radiography (DR) systems, reporting superior performance over conventional algorithms. However, DLNR algorithms often operate as “black boxes” with nonlinear behavior, making it essential to understand the impact of such processing on image quality under different imaging conditions.

Purpose

This study aimed to quantitatively evaluate the image quality of a commercial DLNR algorithm for DR referred to as intelligent noise reduction (INR). Specifically, we compared its noise reduction performance with that of a conventional rule‐based algorithm (conventional noise reduction, Con‐NR) using frequency‐domain metrics with detailed noise power spectrum (NPS) analysis.

Methods

The NPS was used to assess the spatial‐frequency‐dependent behavior of both INR and Con‐NR across varying dose levels and different objects. In this work, we introduced a supplementary metric—the NPS improvement factor (NPSIF)—to quantify noise suppression across frequency ranges and facilitate direct comparison between methods.

Results

The DL‐based algorithm achieved substantial noise reduction at low‐dose settings compared with the conventional method, although its advantages were less pronounced at higher dose levels. The NPSIF effectively captured frequency‐specific differences, thereby offering insights into the strengths and limitations of each technique.

Conclusions

The dose‐dependent performance of the DL‐based algorithm suggests sensitivity to the characteristics of the training data used to develop the DL model. The findings demonstrate distinct differences in the noise suppression behavior between DL‐based and conventional methods in DR and underscore the importance of detailed frequency‐domain evaluation for understanding advanced image processing. Further research is warranted to integrate noise analysis with diagnostic performance metrics to comprehensively assess clinical utility.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Deep LearningRadiographic Image EnhancementAlgorithmsSignal-To-Noise RatioImage Processing, Computer-AssistedPhantoms, ImagingHumans

Stichwörter der Autor:innen

deep learning‐based noise reductiondigital radiographydose‐dependent performancefrequency‐dependent assessmentnoise power spectrum

Autor:innen und Institutionen

  • Department of Radiological Technology, Gunma Prefectural College of Health Sciences, Maebashi, Gunma, Japan.
  • Department of Medical Radiology, Faculty of Medical Technology, Teikyo University, Itabashi-ku, Tokyo, Japan.

ORCID-Profile: Sho Maruyama

Zitieren

APA

Maruyama, S., & Saitou, H. (2026). Quantitative evaluation of a deep learning‐based noise reduction algorithm in digital radiography using noise power spectrum analysis. Journal of Applied Clinical Medical Physics, 27(3). https://doi.org/10.1002/acm2.70521

Vancouver

Maruyama S, Saitou H. Quantitative evaluation of a deep learning‐based noise reduction algorithm in digital radiography using noise power spectrum analysis. Journal of Applied Clinical Medical Physics. 2026;27(3). doi:10.1002/acm2.70521

BibTeX
@article{Maruyama2026,
  author = {Maruyama, Sho and Saitou, Hiroki},
  title = {Quantitative evaluation of a deep learning‐based noise reduction algorithm in digital radiography using noise power spectrum analysis},
  journal = {Journal of Applied Clinical Medical Physics},
  year = {2026},
  volume = {27},
  number = {3},
  doi = {10.1002/acm2.70521}
}