EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Reducing low‐dose exposure in helical TomoTherapy for locally advanced left‐sided breast cancer with a deformable image registration–based dose‐mimicking workflow

Chih-Chieh Chang, Jo-Ting Tsai, Shih-Ming Hsu

Journal of Applied Clinical Medical Physics · 2026

DOI: 10.1002/acm2.70470 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Applied Clinical Medical Physics, 2026. Verfasst von Chih-Chieh Chang und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, Shuang Ho Hospital, Taipei Medical University, New Taipei, Taiwan, ROC. Hauptthemen laut MEDLINE: Radiotherapy, Intensity-Modulated, Radiotherapy Planning, Computer-Assisted, Organs at Risk, Unilateral Breast Neoplasms. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Taipei Medical University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Helical TomoTherapy provides highly conformal dose distributions for breast irradiation but is limited by extensive low‐dose spillage (“low‐dose bath”), contributing to increased integral dose and potential long‐term toxicities. Complete blocks can suppress low‐dose spread, but at the cost of prolonged treatment times on legacy TomoTherapy systems.

Purpose

To develop and validate a deformable image registration (DIR)‐based workflow that predicts patient‐specific low‐dose distributions and generates personalized complete blocks for TomoTherapy, aiming to reduce low‐dose exposure and integral dose. A secondary objective was to determine whether Radixact, a modern helical platform, could mitigate treatment‐time penalties while preserving dosimetric benefits.

Methods

Twenty‐eight patients were retrospectively analyzed (18 tangential partial‐arc volumetric modulated arc therapy [t‐VMAT], 10 TomoTherapy). DIR‐based dose prediction derived from t‐VMAT atlases was used to construct complete blocks for replanning on Hi‐Art (TOMO_RE) and Radixact (TOMO_FA). Dosimetric endpoints included target conformity, homogeneity, organ‐at‐risk (OAR) doses, and integral dose (ID). Statistical analyses used Mann–Whitney U test for independent cohorts and Friedman/Wilcoxon tests for paired TomoTherapy plans with Holm–Bonferroni correction.

Results

TOMO_FA significantly reduced low‐dose exposure compared with TOMO_ORI, including lower contralateral lung mean dose (0.79 vs. 3.13 Gy, p < 0.01) and reduced Heart V5 (12.81% vs. 20.94%, p = 0.027). Body‐PTV ID decreased meaningfully (103.14 vs. 114.52 Gy·L, p = 0.012). High‐dose cardiac parameters (V25, V40) remained within clinically acceptable limits and comparable to t‐VMAT. Treatment time improved substantially on Radixact (587.2 ± 44.3 s vs. 1118.0 ± 135.5 s).

Conclusions

The proposed DIR‐based complete block workflow effectively reduces low‐dose exposure and integral dose in helical TomoTherapy without compromising delivery efficiency when implemented on Radixact. TOMO_FA represents a practical, personalized planning option, particularly for patients requiring stringent low‐dose sparing.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Radiotherapy, Intensity-ModulatedRadiotherapy Planning, Computer-AssistedOrgans at RiskUnilateral Breast NeoplasmsWorkflowImage Processing, Computer-AssistedPhantoms, ImagingHumansFemaleRadiotherapy DosageRetrospective StudiesPrognosisMiddle Aged

Stichwörter der Autor:innen

breast cancer radiotherapydeformable image registrationhelical TomoTherapyradixact

Autor:innen und Institutionen

  • Department of Radiation Oncology, Shuang Ho Hospital, Taipei Medical University, New Taipei, Taiwan, ROC.
  • Medical Physics and Radiation Measurements Laboratory, National Yang Ming Chiao Tung University, Taipei, Taiwan, ROC.
  • Department of Biomedical Imaging and Radiological Sciences, National Yang Ming Chiao Tung University, Taipei, Taiwan, ROC.
  • Graduate Institute of Clinical Medicine, College of Medicine, Taipei Medical University, Taipei, Taiwan, ROC.
  • Department of Radiology, School of Medicine, College of Medicine, Taipei Medical University, Taipei, Taiwan, ROC.

Förderung

  • Taipei Medical University

Zitieren

APA

Chang, C. C., Tsai, J. T., & Hsu, S. M. (2026). Reducing low‐dose exposure in helical TomoTherapy for locally advanced left‐sided breast cancer with a deformable image registration–based dose‐mimicking workflow. Journal of Applied Clinical Medical Physics. https://doi.org/10.1002/acm2.70470

Vancouver

Chang CC, Tsai JT, Hsu SM. Reducing low‐dose exposure in helical TomoTherapy for locally advanced left‐sided breast cancer with a deformable image registration–based dose‐mimicking workflow. Journal of Applied Clinical Medical Physics. 2026. doi:10.1002/acm2.70470

BibTeX
@article{Chang2026,
  author = {Chang, Chih-Chieh and Tsai, Jo-Ting and Hsu, Shih-Ming},
  title = {Reducing low‐dose exposure in helical TomoTherapy for locally advanced left‐sided breast cancer with a deformable image registration–based dose‐mimicking workflow},
  journal = {Journal of Applied Clinical Medical Physics},
  year = {2026},
  doi = {10.1002/acm2.70470}
}
Infokarte | EUVIMED

Artikeldaten derzeit nicht verfügbar.

Recherche