Segmented jaw‐locking in IMRT for upper thoracic esophageal cancer: A plan complexity‐driven approach to lung dose reduction
Journal of Applied Clinical Medical Physics · 2026
DOI: 10.1002/acm2.70467 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Applied Clinical Medical Physics, 2026. Verfasst von Shi Cao und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, Taizhou People's Hospital Affiliated to Nanjing Medical University, Taizhou, Jiangsu, China. Hauptthemen laut MEDLINE: Radiotherapy Planning, Computer-Assisted, Radiotherapy, Intensity-Modulated, Organs at Risk, Esophageal Neoplasms. Die Arbeit nennt 41 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Key R&D Program of China, National Natural Science Foundation of China, National Key Research and Development Program of China.
Abstract (Originalsprache)
Objective
Extended‐field intensity‐modulated radiotherapy (EF‐IMRT) used for elective nodal irradiation (ENI) in upper thoracic esophageal cancer frequently results in excessive intermediate‐to‐low‐dose pulmonary irradiation. This study presented a practical and reproducible planning strategy (segmented Jaw‐locking IMRT, SJL‐IMRT) for optimizing dose distributions to ENI target volumes, and assessed its impact on plan complexity and lung parenchyma sparing.
Methods
In a paired planning study ( n = 40), EF‐IMRT and SJL‐IMRT plans were generated per patient under identical target coverage objectives. SJL‐IMRT partitioned the longitudinal ENI volume into cervical‐supraclavicular and upper‐mediastinal segments via coordinated orthogonal collimators, and multi‐leaf collimator (MLC)‐defined apertures locked within each segment. The evaluation was based on multifaceted criteria, including metrics for: (i) plan complexity: the aperture‐based edge‐area metric (EAM) and the sequence‐level modulation complexity score (MCS); (ii) dosimetry: conformity index (CI), homogeneity index (HI), gradient measure (GM), pulmonary parameters (mean lung dose [MLD], V 5 ∼V 30 ), and spinal cord maximum dose (D max ); (iii) radiobiological effects: tumor control probability (TCP) and normal tissue complication probability (NTCP). The delivery accuracy of SJL‐IMRT and EF‐IMRT was validated with a PTW OCTAVIUS 729 2D ionization chamber array and RW3 phantom, using γ analysis (3.0%/3.0 mm criterion, global normalization, 10% dose threshold). Statistical analysis was performed using Wilcoxon signed‐rank test.
Results
Both SJL‐IMRT and EF‐IMRT satisfied prescription dose objectives for planning target volume (PTV). No significant differences were observed in CI and HI ( p = 0.347 and p = 0.173, respectively). SJL‐IMRT demonstrated lower geometric complexity and simpler sequencing: EAM 8.610 ± 2.951 vs. 20.824 ± 4.944 (paired Δ = −12.214; p = 0.00195) and MCS 0.243 ± 0.015 vs. 0.203 ± 0.036 (paired Δ = +0.040; p = 0.0193), respectively. Compared with EF‐IMRT, SJL‐IMRT (i) reduced gradient measures (GM) by 0.215 cm ( p < 0.01), indicating a steeper dose fall‐off; (ii) decreased MLD by 1.62 Gy (left) and 2.64 Gy (right); (iii) lowered left lung V 5 and V 20 by 19.96%, 3.63%, right lung V 5 and V 20 by 25.27%, 3.05%, respectively (all p < 0.01); (iv) exhibited a marginally higher mean γ passing rate (99.4 ± 0.72% vs. 98.8 ± 0.75%, p = 0.048), no dose cold/hot spots in the 2‐cm feathered overlap, and a more compact high‐dose area; (v) demonstrated a longer mean delivery time (10.9 vs. 8.8 min, p = 0.021) and higher total monitor units (MUs: 2893 vs. 2066; p = 0.026). (vi) translated these dosimetric gains into significant NTCP reductions for both lungs (left −1.30%, right −1.29%; p < 0.01). TCP values were numerically higher for SJL‐IMRT, but these differences were not statistically significant; D max to the spinal cord followed the same pattern.
Conclusion
SJL‐IMRT reduces plan complexity (EAM↓, MCS↑) and lowers intermediate‐to‐low lung dose compared with EF‐IMRT for ENI in upper thoracic esophageal cancer, without compromising target coverage, supporting SJL‐IMRT as a pragmatic approach to improving dosimetric quality and delivery simplicity. Confirmation in larger cohorts is warranted.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiation Oncology, Taizhou People's Hospital Affiliated to Nanjing Medical University, Taizhou, Jiangsu, China.
- Department of Radiology, Taizhou People's Hospital Affiliated to Nanjing Medical University, Taizhou, Jiangsu, China.
- Institute of Medical Instruments, School of Biomedical Engineering, Southern Medical University, Guangzhou, Guangdong, China.
- Department of Medical Engineering, Zhujiang Hospital, Southern Medical University, Guangzhou, Guangdong, China.
ORCID-Profile: Shi Cao
Förderung
- National Key R&D Program of China
- National Natural Science Foundation of China
- National Key Research and Development Program of China
Zitieren
APA
Cao, S., Sun, G. Z., Gao, J. Y., Dai, X., Wang, H., Chen, C. M., Xu, W. S., & Fang, Y. H. (2026). Segmented jaw‐locking in IMRT for upper thoracic esophageal cancer: A plan complexity‐driven approach to lung dose reduction. Journal of Applied Clinical Medical Physics. https://doi.org/10.1002/acm2.70467
Vancouver
Cao S, Sun GZ, Gao JY, Dai X, Wang H, Chen CM, et al. Segmented jaw‐locking in IMRT for upper thoracic esophageal cancer: A plan complexity‐driven approach to lung dose reduction. Journal of Applied Clinical Medical Physics. 2026. doi:10.1002/acm2.70467
BibTeX
@article{Cao2026,
author = {Cao, Shi and Sun, Guang-Zhi and Gao, Jun-Yi and Dai, Xiang and Wang, Hao and Chen, Chao-Min and Xu, Wan-Song and Fang, Yi-Hai},
title = {Segmented jaw‐locking in IMRT for upper thoracic esophageal cancer: A plan complexity‐driven approach to lung dose reduction},
journal = {Journal of Applied Clinical Medical Physics},
year = {2026},
doi = {10.1002/acm2.70467}
}
EUVIMED