EUVIMEDEUVIMED entdecken
EvaluationsstudieOpen Access · CC BY 4.0

Development and evaluation of deep learning models for estimating the organ at‐risk dose constraint from two‐dimensional cine magnetic resonance imaging scans during irradiation

Shohei Tanaka, Noriyuki Kadoya iD, Wingyi Lee, Hisamichi Takagi, Yoshiyuki Katsuta, Kazuhiro Arai, Yushan Xiao, Taichi Hoshino iD, Noriyoshi Takahashi, Keiichi Jingu

Journal of Applied Clinical Medical Physics · 2025

DOI: 10.1002/acm2.70403 ↗

Kurz gefasst

Evaluationsstudie in der Zeitschrift Journal of Applied Clinical Medical Physics, 2025. Verfasst von Shohei Tanaka und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, Tohoku University Graduate School of Medicine, Sendai, Japan. Hauptthemen laut MEDLINE: Deep Learning, Prostatic Neoplasms, Organs at Risk, Magnetic Resonance Imaging, Cine. Die Arbeit nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: JSPS, Japan Society for the Promotion of Science.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Two‐dimensional (2D) cine magnetic resonance imaging (MRI), available with a MR‐linear accelerator (MR‐Linac), allows real‐time visualization of anatomical information during irradiation. The present study aimed to develop and evaluate a deep learning model that can estimate the organ‐at‐risk (OAR) dose constraints (mainly bladder V37Gy) from 2D cine MRI.

Methods

The present study enrolled 91 prostate cancer patients treated with MR‐Linac. From 381 treatment fractions, sagittal images at the start and end of the 2D cine MRI were extracted. Additionally, 3D MRI data acquired pre‐ and post‐irradiation were collected, from which bladder V37Gy was calculated. We designed the deep learning model to predict the end‐of‐irradiation bladder V37Gy value based on the bladder image on the end‐of‐irradiation 2D cine MRI. The model inputs included the start and end 2D cine MR images, a difference image between them, and the pre‐irradiation bladder V37Gy. The model output was the post‐irradiation bladder V37Gy. We utilized a five‐fold cross‐validation for model training and evaluated the performance using a test dataset. For reference, we also evaluated the predictions made using only the pre‐irradiation bladder V37Gy.

Results

In the test dataset, the model‐predicted and true bladder V37Gy values showed a strong correlation ( r = 0.89), with a mean absolute error (MAE) of 1.40 cm 3 . Using only the pre‐irradiation bladder V37Gy value yielded an r of 0.79 and an MAE of 2.02 cm 3 . Our model also achieved an area under the curve, sensitivity, and specificity values of 0.98, 0.91, and 0.95, respectively, in detecting dose constraint violations (bladder V37Gy of > 10 cm 3 ).

Conclusions

Our results demonstrated that deep learning can effectively predict the OAR dose constraints during irradiation. However, it is noteworthy that these results show only a limited improvement and are constrained by several limitations.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Deep LearningProstatic NeoplasmsOrgans at RiskMagnetic Resonance Imaging, CineRadiotherapy Planning, Computer-AssistedUrinary BladderImage Processing, Computer-AssistedHumansMaleRadiotherapy DosageRadiotherapy, Intensity-ModulatedParticle AcceleratorsAged

Stichwörter der Autor:innen

2D cine MRIMR‐Linacdeep learningdose predictionradiotherapy

Autor:innen und Institutionen

  • Department of Radiation Oncology, Tohoku University Graduate School of Medicine, Sendai, Japan.
  • Department of Radiological Technology, School of Health Sciences, Faculty of Medicine, Tohoku University, Sendai, Japan.

ORCID-Profile: Noriyuki Kadoya, Taichi Hoshino

Förderung

  • JSPS
  • Japan Society for the Promotion of Science

Zitieren

APA

Tanaka, S., Kadoya, N., Lee, W., Takagi, H., Katsuta, Y., Arai, K., Xiao, Y., Hoshino, T., Takahashi, N., & Jingu, K. (2025). Development and evaluation of deep learning models for estimating the organ at‐risk dose constraint from two‐dimensional cine magnetic resonance imaging scans during irradiation. Journal of Applied Clinical Medical Physics. https://doi.org/10.1002/acm2.70403

Vancouver

Tanaka S, Kadoya N, Lee W, Takagi H, Katsuta Y, Arai K, et al. Development and evaluation of deep learning models for estimating the organ at‐risk dose constraint from two‐dimensional cine magnetic resonance imaging scans during irradiation. Journal of Applied Clinical Medical Physics. 2025. doi:10.1002/acm2.70403

BibTeX
@article{Tanaka2025,
  author = {Tanaka, Shohei and Kadoya, Noriyuki and Lee, Wingyi and Takagi, Hisamichi and Katsuta, Yoshiyuki and Arai, Kazuhiro and Xiao, Yushan and Hoshino, Taichi and Takahashi, Noriyoshi and Jingu, Keiichi},
  title = {Development and evaluation of deep learning models for estimating the organ at‐risk dose constraint from two‐dimensional cine magnetic resonance imaging scans during irradiation},
  journal = {Journal of Applied Clinical Medical Physics},
  year = {2025},
  doi = {10.1002/acm2.70403}
}
Kostenlos starten →