EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY 4.0

Bilateral breast treatment in a single arc using RapidArc Dynamic: A planning comparison with conventional volumetric modulated arc therapy

Taoran Li, Luca Cozzi, Lesley Rosa, Ryan Clark, Priyanka Agarwal, Yin Gao, Yun Yang, Boon-Keng Kevin Teo, Anthony Magliari, Himank Kalra, Francisco Reynoso, Patrick Kupelian und 1 weitere

Journal of Applied Clinical Medical Physics · 2025-12 · 26 (12)

DOI: 10.1002/acm2.70380 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Journal of Applied Clinical Medical Physics, online erschienen am 21.11.2025. Verfasst von Taoran Li und 12 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, University of Pennsylvania, Philadelphia, Pennsylvania, USA. Hauptthemen laut MEDLINE: Radiotherapy Planning, Computer-Assisted, Radiotherapy, Intensity-Modulated, Breast Neoplasms, Organs at Risk. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Synchronous bilateral breast cancer (SBBC) presents significant radiotherapy planning challenges due to complex target volumes near critical organs. This study evaluated RapidArc Dynamic (RAD), a novel technique integrating dynamic arcs with static angle modulated ports (STAMPs) via simultaneous GPU‐accelerated optimization, against conventional volumetric modulated arc therapy (VMAT) for SBBC treatment planning and delivery efficiency.

Methods

Ten retrospective SBBC cases involving comprehensive nodal irradiation were planned using both multi‐arc VMAT (six arcs) and RAD (one arc plus six STAMPs) in Eclipse (v18.1) with AcurosXB. A prescription dose of 40.05 Gy in 15 fractions was normalized to PTV D95% = 95%. Paired Wilcoxon signed‐rank tests compared planning target volume (PTV) coverage (V95%, V105%) and organ‐at‐risk (OAR) doses, including lungs (V5Gy, V10Gy, V20Gy), heart (D mean , V15Gy), and esophagus (D mean , D0.03 cm 3 ). Planning time, monitor units (MU), and measured delivery times were also assessed.

Results

RAD plans achieved clinical goals more frequently than VMAT plans (90% vs. 70% of endpoints). PTV V95% coverage was comparable between the two techniques. However, RAD significantly improved breast dose homogeneity (lower median PTVp V105%; p < 0.05) and OAR sparing. Notably, RAD reduced median lung V5Gy by 9.7% ( p < 0.001) and esophageal D0.03 cm 3 by 5.4 Gy ( p = 0.002). RAD significantly reduced planning time (avg 16 vs. 39 min), mean MU (1654 vs. 2268; ∼30% reduction), and mean measured delivery time (2.2 vs. 5.8 min; ∼62% reduction).

Conclusion

For SBBC radiotherapy, RAD demonstrated significant dosimetric improvements over conventional VMAT, particularly reducing low‐dose lung and high‐dose esophageal irradiation while enhancing target homogeneity. The substantial gains in planning and delivery efficiency further establish RAD as a highly advantageous technique for managing these complex cases.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Radiotherapy Planning, Computer-AssistedRadiotherapy, Intensity-ModulatedBreast NeoplasmsOrgans at RiskHumansFemaleRadiotherapy DosageRetrospective Studies

Stichwörter der Autor:innen

RapidArc Dynamic (RAD)delivery efficiencysynchronous bilateral breast cancer (SBBC)treatment planningvolumetric modulated arc therapy (VMAT)

Autor:innen und Institutionen

  • Department of Radiation Oncology, University of Pennsylvania, Philadelphia, Pennsylvania, USA.
  • Varian Medical Systems, Palo Alto, California, USA.
  • Humanitas Cancer Center and Research Hospital, Rozzano, Italy.
  • Washington University School of Medicine in St. Louis, Department of Radiation Oncology, St. Louis, Missouri, USA.
  • Department of Radiation Oncology, University of California, Los Angeles, California, USA.
  • Allegheny Health Network, Pittsburgh, Pennsylvania, USA.

Zitieren

APA

Li, T., Cozzi, L., Rosa, L., Clark, R., Agarwal, P., Gao, Y., Yang, Y., Teo, B. K., Magliari, A., Kalra, H., Reynoso, F., Kupelian, P., & Beriwal, S. (2025). Bilateral breast treatment in a single arc using RapidArc Dynamic: A planning comparison with conventional volumetric modulated arc therapy. Journal of Applied Clinical Medical Physics, 26(12). https://doi.org/10.1002/acm2.70380

Vancouver

Li T, Cozzi L, Rosa L, Clark R, Agarwal P, Gao Y, et al. Bilateral breast treatment in a single arc using RapidArc Dynamic: A planning comparison with conventional volumetric modulated arc therapy. Journal of Applied Clinical Medical Physics. 2025;26(12). doi:10.1002/acm2.70380

BibTeX
@article{Li2025,
  author = {Li, Taoran and Cozzi, Luca and Rosa, Lesley and Clark, Ryan and Agarwal, Priyanka and Gao, Yin and Yang, Yun and Teo, Boon-Keng Kevin and Magliari, Anthony and Kalra, Himank and Reynoso, Francisco and Kupelian, Patrick and Beriwal, Sushil},
  title = {Bilateral breast treatment in a single arc using RapidArc Dynamic: A planning comparison with conventional volumetric modulated arc therapy},
  journal = {Journal of Applied Clinical Medical Physics},
  year = {2025},
  volume = {26},
  number = {12},
  doi = {10.1002/acm2.70380}
}
Kostenlos starten →