Dosimetric evaluation of Ethos 2.0 high‐fidelity mode for single‐isocenter SRS
Journal of Applied Clinical Medical Physics · 2025
DOI: 10.1002/acm2.70370 ↗Kurz gefasst
Evaluationsstudie in der Zeitschrift Journal of Applied Clinical Medical Physics, 2025. Verfasst von Udbhav S Ram und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, The University of Alabama at Birmingham, Birmingham, Alabama, USA. Hauptthemen laut MEDLINE: Radiotherapy Planning, Computer-Assisted, Radiosurgery, Brain Neoplasms, Organs at Risk. Die Arbeit nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: University of Alabama at Birmingham Faculty Development Grant Program.
Abstract (Originalsprache)
Purpose
This study evaluates the impact of the Ethos 2.0 high‐fidelity (HF) mode on single‐isocenter, stereotactic radiosurgery (SRS) planning workflows. By comparing different planning templates, we assess the effects of HF mode and control rings (R) on plan quality, aiming to optimize treatment for patients with brain metastases.
Methods
A cohort of 45 patients with brain metastases was divided into a tuning ( n = 15) and a validation set ( n = 30). Four planning templates were evaluated: HFonRon, HFonRoff, HFoffRon, and HFoffRoff. Plans were generated using the Ethos Intelligent Optimization Engine (IOE v02.00.10), and all patients were prescribed 30 Gy in 5 fractions using 2 mm PTV margins. Plan quality was evaluated using target coverage (PTV V100%), normal brain dose (Brain‐PTV V30Gy), Paddick conformity index (CI), and Falloff index. Plan complexity was evaluated using total MU's on a per‐plan basis across the four templates.
Results
The HFonRon template produced better quality plans, achieving significant improvements in normal tissue sparing ( p < 0.0001), CI ( p < 0.0001), and Falloff index ( p < 0.0001) compared to other templates. All templates provided clinically acceptable target coverage. In the HFoffRoff configuration, 97.5 % of targets met the coverage criterion (V100% > 95%). The other setups achieved coverage in 99.2% (HFoffRon), 96.6% (HFonRoff), and 98.3% (HFonRon) of targets, respectively. Plan complexity decreased significantly ( p < 0.0001) when enabling HF mode compared to both HF disabled templates Conclusions His study shows that combining Ethos 2.0's high‐fidelity mode with user‐defined control rings yields superior single‐isocenter SRS plans compared with planning strategies that omit one or both features. This approach improves dose conformity, reduces normal tissue exposure, and decreases plan complexity through semi‐automated, template‐based planning. These findings suggest that HF mode can be a valuable tool in clinical practice for optimizing SRS treatments for patients with brain metastases.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiation Oncology, The University of Alabama at Birmingham, Birmingham, Alabama, USA.
- Department of Physics and Astronomy, McMaster University, Hamilton, Ontario, Canada.
ORCID-Profile: Udbhav S Ram, Richard A Popple
Förderung
- University of Alabama at Birmingham Faculty Development Grant Program
Zitieren
APA
Ram, U. S., Popple, R. A., Fiveash, J. B., Heinzman, K. A., Kumar, Y., Viscariello, N. N., Stanley, C. B., Stanley, D. N., Cardenas, C. E., & Pogue, J. A. (2025). Dosimetric evaluation of Ethos 2.0 high‐fidelity mode for single‐isocenter SRS. Journal of Applied Clinical Medical Physics. https://doi.org/10.1002/acm2.70370
Vancouver
Ram US, Popple RA, Fiveash JB, Heinzman KA, Kumar Y, Viscariello NN, et al. Dosimetric evaluation of Ethos 2.0 high‐fidelity mode for single‐isocenter SRS. Journal of Applied Clinical Medical Physics. 2025. doi:10.1002/acm2.70370
BibTeX
@article{Ram2025,
author = {Ram, Udbhav S and Popple, Richard A and Fiveash, John B and Heinzman, Katherine A and Kumar, Yogesh and Viscariello, Natalie N and Stanley, Courtney B and Stanley, Dennis N and Cardenas, Carlos E and Pogue, Joel A},
title = {Dosimetric evaluation of Ethos 2.0 high‐fidelity mode for single‐isocenter SRS},
journal = {Journal of Applied Clinical Medical Physics},
year = {2025},
doi = {10.1002/acm2.70370}
}
EUVIMED