EUVIMEDEUVIMED entdecken
EvaluationsstudieOpen Access · CC BY 4.0

Dosimetric evaluation of Ethos 2.0 high‐fidelity mode for single‐isocenter SRS

Udbhav S Ram iD, Richard A Popple iD, John B Fiveash, Katherine A Heinzman, Yogesh Kumar, Natalie N Viscariello, Courtney B Stanley, Dennis N Stanley, Carlos E Cardenas, Joel A Pogue

Journal of Applied Clinical Medical Physics · 2025

DOI: 10.1002/acm2.70370 ↗

Kurz gefasst

Evaluationsstudie in der Zeitschrift Journal of Applied Clinical Medical Physics, 2025. Verfasst von Udbhav S Ram und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, The University of Alabama at Birmingham, Birmingham, Alabama, USA. Hauptthemen laut MEDLINE: Radiotherapy Planning, Computer-Assisted, Radiosurgery, Brain Neoplasms, Organs at Risk. Die Arbeit nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: University of Alabama at Birmingham Faculty Development Grant Program.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

This study evaluates the impact of the Ethos 2.0 high‐fidelity (HF) mode on single‐isocenter, stereotactic radiosurgery (SRS) planning workflows. By comparing different planning templates, we assess the effects of HF mode and control rings (R) on plan quality, aiming to optimize treatment for patients with brain metastases.

Methods

A cohort of 45 patients with brain metastases was divided into a tuning ( n = 15) and a validation set ( n = 30). Four planning templates were evaluated: HFonRon, HFonRoff, HFoffRon, and HFoffRoff. Plans were generated using the Ethos Intelligent Optimization Engine (IOE v02.00.10), and all patients were prescribed 30 Gy in 5 fractions using 2 mm PTV margins. Plan quality was evaluated using target coverage (PTV V100%), normal brain dose (Brain‐PTV V30Gy), Paddick conformity index (CI), and Falloff index. Plan complexity was evaluated using total MU's on a per‐plan basis across the four templates.

Results

The HFonRon template produced better quality plans, achieving significant improvements in normal tissue sparing ( p < 0.0001), CI ( p < 0.0001), and Falloff index ( p < 0.0001) compared to other templates. All templates provided clinically acceptable target coverage. In the HFoffRoff configuration, 97.5 % of targets met the coverage criterion (V100% > 95%). The other setups achieved coverage in 99.2% (HFoffRon), 96.6% (HFonRoff), and 98.3% (HFonRon) of targets, respectively. Plan complexity decreased significantly ( p < 0.0001) when enabling HF mode compared to both HF disabled templates Conclusions His study shows that combining Ethos 2.0's high‐fidelity mode with user‐defined control rings yields superior single‐isocenter SRS plans compared with planning strategies that omit one or both features. This approach improves dose conformity, reduces normal tissue exposure, and decreases plan complexity through semi‐automated, template‐based planning. These findings suggest that HF mode can be a valuable tool in clinical practice for optimizing SRS treatments for patients with brain metastases.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Radiotherapy Planning, Computer-AssistedRadiosurgeryBrain NeoplasmsOrgans at RiskHumansRadiotherapy DosageRadiotherapy, Intensity-ModulatedAlgorithmsRadiometry

Stichwörter der Autor:innen

adaptive radiotherapystereotactic radiosurgerytemplate‐based planning

Autor:innen und Institutionen

  • Department of Radiation Oncology, The University of Alabama at Birmingham, Birmingham, Alabama, USA.
  • Department of Physics and Astronomy, McMaster University, Hamilton, Ontario, Canada.

ORCID-Profile: Udbhav S Ram, Richard A Popple

Förderung

  • University of Alabama at Birmingham Faculty Development Grant Program

Zitieren

APA

Ram, U. S., Popple, R. A., Fiveash, J. B., Heinzman, K. A., Kumar, Y., Viscariello, N. N., Stanley, C. B., Stanley, D. N., Cardenas, C. E., & Pogue, J. A. (2025). Dosimetric evaluation of Ethos 2.0 high‐fidelity mode for single‐isocenter SRS. Journal of Applied Clinical Medical Physics. https://doi.org/10.1002/acm2.70370

Vancouver

Ram US, Popple RA, Fiveash JB, Heinzman KA, Kumar Y, Viscariello NN, et al. Dosimetric evaluation of Ethos 2.0 high‐fidelity mode for single‐isocenter SRS. Journal of Applied Clinical Medical Physics. 2025. doi:10.1002/acm2.70370

BibTeX
@article{Ram2025,
  author = {Ram, Udbhav S and Popple, Richard A and Fiveash, John B and Heinzman, Katherine A and Kumar, Yogesh and Viscariello, Natalie N and Stanley, Courtney B and Stanley, Dennis N and Cardenas, Carlos E and Pogue, Joel A},
  title = {Dosimetric evaluation of Ethos 2.0 high‐fidelity mode for single‐isocenter SRS},
  journal = {Journal of Applied Clinical Medical Physics},
  year = {2025},
  doi = {10.1002/acm2.70370}
}
Infokarte | EUVIMED

Artikeldaten derzeit nicht verfügbar.

Recherche