Kurz gefasst

Fachartikel in der Zeitschrift Journal of Applied Clinical Medical Physics, 2025. Verfasst von Denghong Liu und 12 weiteren Autor:innen. Beteiligte Einrichtung: Radiotherapy Physics & Technology Center, Cancer Center, West China Hospital, Sichuan University, Chengdu, People's Republic of China. Hauptthemen laut MEDLINE: Radiotherapy Planning, Computer-Assisted, Organs at Risk, Breast Neoplasms, Radiotherapy, Intensity-Modulated. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 47 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

This study aimed to assess the dosimetric and radiobiological consequences of rotational errors in breast cancer radiotherapy.

Methods

A retrospective analysis involving 80 breast cancer patients was performed. We simulated 124 rotational scenarios across three axes (yaw, pitch, and roll) to generate rotated dose distributions, then evaluated their dosimetric effects alongside tumor control probability (TCP) and normal tissue complication probability (NTCP) for the target and organs at risk (OARs).

Results

Rotational errors caused significant dose deviations. The D95 for PTV, heart, ipsilateral lung, contralateral breast, and left anterior descending artery (LAD V40 ) in rotated dose distributions showed statistical significance compared to the original dose ( p < 0.05), except for LAD V40 in the whole‐breast radiation therapy (WBRT) left4005 cohort ( p = 0.058). LAD V40 and PTV sc were primarily affected in left‐sided breast cancer, while PTV sc and PTV cw were predominantly affected in right‐sided breast cancer. TCP decreased from 0.91 to 0.81 in the WBRT 4005 cohort, from 0.95 to 0.70 in the WBRT 5000 cohort, and from 0.87 to 0.23 in postmastectomy radiation therapy (PMRT) 5000 cohort. NTCP for the heart increased from 2.08 × 10 −14 to 5.78 × 10 −10 , and NTCP for the lung increased from 1.82 × 10 −3 to 1.37 × 10 −2 . When single‐axis rotations were involved, the pitch direction was more likely to cause dose deviations. For multi‐axis (≥2) rotations, opposite‐direction yaw and pitch rotations in left‐sided breast cancer and same‐direction yaw and pitch rotations in right‐sided breast were more prone to exceeding dose limits.

Conclusion

The dosimetric and radiobiological analysis of rotational errors demonstrated that rotational errors (particularly in pitch and yaw) induce significant dosimetric deviations, compromising tumor control probability and increasing normal tissue complication probability. It identifies rotational axes requiring correction during multi‐axis rotations and provides recommendations for prioritizing targets versus organs at risk during image‐guided registration. Implementing these corrections and prioritization strategies is essential for optimizing therapeutic efficacy in breast radiotherapy.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Radiotherapy Planning, Computer-AssistedOrgans at RiskBreast NeoplasmsRadiotherapy, Intensity-ModulatedRadiotherapy Setup ErrorsHumansFemaleRadiotherapy DosageRetrospective StudiesRotationRadiobiologyRadiometry

Stichwörter der Autor:innen

breast cancer radiotherapydosimetrynormal tissue complication probabilityrotational errorstumor control probability

Autor:innen und Institutionen

  • Radiotherapy Physics & Technology Center, Cancer Center, West China Hospital, Sichuan University, Chengdu, People's Republic of China.
  • Department of Oncology, Fifth People's Hospital Affiliated to Chengdu University of Traditional Chinese Medicine, Chengdu, People's Republic of China.

ORCID-Profile: Denghong Liu, Renming Zhong

Zitieren

APA

Liu, D., Zhong, Q., Wang, Y., Gong, P., Zhang, X., Lai, J., Wang, S., Liu, S., Deng, Z., Shen, K., Du, B., Peng, R., & Zhong, R. (2025). The dosimetric and radiobiological effects of rotational errors in breast cancer radiotherapy. Journal of Applied Clinical Medical Physics. https://doi.org/10.1002/acm2.70303

Vancouver

Liu D, Zhong Q, Wang Y, Gong P, Zhang X, Lai J, et al. The dosimetric and radiobiological effects of rotational errors in breast cancer radiotherapy. Journal of Applied Clinical Medical Physics. 2025. doi:10.1002/acm2.70303

BibTeX
@article{Liu2025,
  author = {Liu, Denghong and Zhong, Quan and Wang, Ya and Gong, Pan and Zhang, Xiangbin and Lai, Jialu and Wang, Shichao and Liu, Shoupeng and Deng, Zhonghua and Shen, Konglong and Du, Bin and Peng, Ruilin and Zhong, Renming},
  title = {The dosimetric and radiobiological effects of rotational errors in breast cancer radiotherapy},
  journal = {Journal of Applied Clinical Medical Physics},
  year = {2025},
  doi = {10.1002/acm2.70303}
}