Development of a hybrid automated chart checking, data collection, and analysis system
Journal of Applied Clinical Medical Physics · 2025
DOI: 10.1002/acm2.70161 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Applied Clinical Medical Physics, 2025. Verfasst von Edward L Clouser und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, Mayo Clinic Arizona, Phoenix, Arizona, USA. Hauptthemen laut MEDLINE: Data Collection, User-Computer Interface, Checklist, Radiotherapy Planning, Computer-Assisted. Die Arbeit nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Purpose
To describe the creation and clinical deployment of an integrated stand‐alone hybrid automated chart review platform that is comprised of a database, oncology information system (OIS) interfaces, and a user interface (UI).
Methods
A consensus checklist was developed to homogenize the practices of clinical physics staff and physics residents for all plan types. Critical review of the single checklist's items led to the creation of a new concept, the “plan attribute,” which permits specialization of the final checklist based on the characteristics of a particular plan. Only relevant and applicable tests are automatically populated to form a plan checklist based on plan attributes. Each populated checklist in this hybrid automation platform includes elements of full automation, steps or functions that use automation to augment a human input or effort, as well as steps completed by humans. Logging and categorizing of deficiencies found during the chart check was also implemented.
Results
Chart check data was analyzed for an over 4‐year time span starting from the clinical deployment of the tool in October 2020. This analysis included a total of 427 073 tests spread among 7882 initial chart checks. The recorded deficiencies at three triage levels showed 7116 minor errors, 679 major errors, and 71 plan rejections. The plan rejection level is the highest chart deficiency, which required the plan to be rejected and sent back for serious remediation and/or new plan generation.
Conclusion
This report describes the successful development and implementation of a hybrid‐automated chart checking program. The software leverages modern database and software design to improve the per case performance and experience of a multi‐user group. Chart check database permits high‐level review and improvement in all aspects of plan check and user performance.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiation Oncology, Mayo Clinic Arizona, Phoenix, Arizona, USA.
ORCID-Profile: Yi Rong
Zitieren
APA
Clouser, E. L., Chen, Q., Harrington, D. P., Rong, Y., & Buckey, C. R. (2025). Development of a hybrid automated chart checking, data collection, and analysis system. Journal of Applied Clinical Medical Physics. https://doi.org/10.1002/acm2.70161
Vancouver
Clouser EL, Chen Q, Harrington DP, Rong Y, Buckey CR. Development of a hybrid automated chart checking, data collection, and analysis system. Journal of Applied Clinical Medical Physics. 2025. doi:10.1002/acm2.70161
BibTeX
@article{Clouser2025,
author = {Clouser, Edward L and Chen, Quan and Harrington, Daniel P and Rong, Yi and Buckey, Courtney R},
title = {Development of a hybrid automated chart checking, data collection, and analysis system},
journal = {Journal of Applied Clinical Medical Physics},
year = {2025},
doi = {10.1002/acm2.70161}
}
EUVIMED