In vivo transit dosimetry methodology for whole breast intensity modulated radiation therapy

Lucia Zirone iD, Elisa Bonanno, Giuseppina R Borzì iD, Nina Cavalli, Alessia D'Anna iD, Andrea Girlando, Martina Pace iD, Giuseppe Stella iD, Carmelo Marino iD

Journal of Applied Clinical Medical Physics · 2025

DOI: 10.1002/acm2.70072 ↗

At a glance

Journal article in Journal of Applied Clinical Medical Physics, 2025. Written by Lucia Zirone and 8 co-authors. Institution: Medical Physics Department, Humanitas Istituto Clinico Catanese, Misterbianco, Italy. Major MEDLINE topics: Radiotherapy, Intensity-Modulated, Breast Neoplasms, Radiotherapy Planning, Computer-Assisted, Radiometry. Cited 1 times so far (Crossref); 38 references. The full text is freely available (open access, CC BY 4.0).

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Background

In vivo transit dosimetry using an electronic portal imaging device (EPID‐IVTD) is an important tool for verifying the accuracy of radiation therapy treatments. Despite its potential, the implementation of EPID‐IVTD in breast intensity modulated radiation therapy (IMRT) treatments has not yet been standardized, limiting its clinical adoption. A standardized EPID‐IVTD method could enhance treatment accuracy and improve patient safety in routine clinical practice.

Purpose

This study aims to develop a method for EPID‐IVTD for whole breast IMRT treatment.

Methods

Gamma passing rates (GPRs) analysis was the basis of the work conducted on a dataset of 50 patients. The first phase of the work focused on the identification of the reference fraction. In the second phase a method for performing EPID‐IVTD was implemented. Lower‐tolerance and ‐action limits (l‐TL and l‐AL), as introduced by AAPM TG 218, were employed to determine the reference fraction and used as alert and alarm thresholds, respectively, in EPID‐IVTD monitoring.

Results

The first treatment fraction demonstrated the best dosimetric agreement with the theoretical plan and was therefore used as the reference in the second phase of the study. EPID‐IVTD results showed that 75% of the GPRs ranged from 97.5% to 99.9%, 93.83% were above the l‐TL, 4.31% fell between l‐TL and l‐AL, and 1.86% were below l‐AL.

Conclusions

A method for the implementation of an effective EPID‐IVTD in whole breast IMRT treatment was developed and is now routinely applied at our center, enabling efficient monitoring in clinical practice.

Subjects

MeSH terms (MEDLINE)

Radiotherapy, Intensity-ModulatedBreast NeoplasmsRadiotherapy Planning, Computer-AssistedRadiometryIn Vivo DosimetryHumansRadiotherapy DosageFemaleOrgans at Risk

Author keywords

EPIDgamma passing ratein vivo transit dosimetry

Authors and institutions

  • Medical Physics Department, Humanitas Istituto Clinico Catanese, Misterbianco, Italy.
  • University of Catania, Department of Physics and Astronomy "Ettore Majorana", Catania, Italy.
  • Radiotherapy Department, Humanitas Istituto Clinico Catanese, Misterbianco, Italy.

ORCID profiles: Lucia Zirone, Giuseppina R Borzì, Alessia D'Anna, Martina Pace, Giuseppe Stella, Carmelo Marino

Cite

APA

Zirone, L., Bonanno, E., Borzì, G. R., Cavalli, N., D'Anna, A., Girlando, A., Pace, M., Stella, G., & Marino, C. (2025). In vivo transit dosimetry methodology for whole breast intensity modulated radiation therapy. Journal of Applied Clinical Medical Physics. https://doi.org/10.1002/acm2.70072

Vancouver

Zirone L, Bonanno E, Borzì GR, Cavalli N, D'Anna A, Girlando A, et al. In vivo transit dosimetry methodology for whole breast intensity modulated radiation therapy. Journal of Applied Clinical Medical Physics. 2025. doi:10.1002/acm2.70072

BibTeX
@article{Zirone2025,
  author = {Zirone, Lucia and Bonanno, Elisa and Borzì, Giuseppina R and Cavalli, Nina and D'Anna, Alessia and Girlando, Andrea and Pace, Martina and Stella, Giuseppe and Marino, Carmelo},
  title = {In vivo transit dosimetry methodology for whole breast intensity modulated radiation therapy},
  journal = {Journal of Applied Clinical Medical Physics},
  year = {2025},
  doi = {10.1002/acm2.70072}
}
Start for free →