Fachartikel in der Zeitschrift Journal of Applied Clinical Medical Physics, 2025. Verfasst von Shuangquan Ai und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Hubei Cancer Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China. Hauptthemen laut MEDLINE: Uterine Cervical Neoplasms, Diffusion Magnetic Resonance Imaging, Image Processing, Computer-Assisted, Radiotherapy Planning, Computer-Assisted. Die Arbeit nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Hubei Province "Chutian Talents Program" medical and health personnel project, National key Research and Development Program of China, Hubei Provincial Key Technology Foundation of China, The Key Research and Development Plan of Hubei Province.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

The aim of this study was to investigate the influence of the simultaneous multislice acceleration (SMS) technique as well as two‐dimensional (2D) and three‐dimensional (3D) tumor segmentations on radiomics features (RFs) within the parametric maps of cervical cancer, which were computed by intravoxel incoherent motion (IVIM) and diffusion kurtosis imaging (DKI). Additionally, the study sought to identify those RFs that could characterize the clinical stages (low‐stage vs. high‐stage) of cervical cancer. Materials and methods Multi‐ b ‐value diffusion‐weighted imaging (DWI) of 40 patients with cervical cancer were collected using the SMS technique with acceleration factors (AF) of 1–3. RFs were extracted from parametric maps representing pure diffusion coefficient (D), pseudodiffusion coefficient (D*), perfusion fraction (f), mean diffusivity (MD), and mean kurtosis (MK). A total of 93 2D and 93 3D RFs were extracted from per parametric map. The concordance correlation coefficient (CCC) and coefficients of variation (COV) were used to jointly assess the stability of features. Finally, the intra‐class correlation coefficient (ICC) was used for intra‐group consistency assessment. Receiver operating characteristic (ROC) curve was used to evaluate diagnostic performance of stable features in distinguishing lower and higher stages.

Results

Feature stability decreased with higher AF. Among these features, 9.1% of 2D and 12.7% of 3D RFs were stable (CCC > 0.9 and COV ≤ 0.1). ADC maps had the highest stability, whileas D * and f maps had the lowest stability and 3D features were more stable than 2D features. A total of 5 2D and 25 3D stable features were identified that could distinguish lower and higher stages (AUC = 0.66–0.83).

Conclusion

SMS demonstrated impact on the stability of RFs in IVIM and DKI parametric maps, particularly for D* and f maps. Multi‐ b ‐value DWI with SMS (AF = 2) was recommended for clinical radiomics research.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Uterine Cervical NeoplasmsDiffusion Magnetic Resonance ImagingImage Processing, Computer-AssistedRadiotherapy Planning, Computer-AssistedHumansFemaleMiddle AgedAdultAlgorithmsAgedRadiotherapy, Intensity-ModulatedImaging, Three-DimensionalRadiomics

Stichwörter der Autor:innen

cervical cancerdiffusion kurtosis imagingintravoxel incoherent motionradiomics featuresstability

Autor:innen und Institutionen

  • Department of Radiology, Hubei Cancer Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China.
  • College of Biomedical Engineering, South-Central Minzu University, Wuhan, Hubei, China.
  • Department of Patholoogy, Suizhou Hospital Affiliated to Hubei Medical College, Shiyan, Hubei, China.
  • MR Scientific Marketing, Siemens Healthineers, Wuhan, China.
  • MR Application Predevelopment, Siemens Healthcare GmbH, Erlangen, Germany.

ORCID-Profile: Shuangquan Ai, Zilong Yuan

Förderung

  • Hubei Province "Chutian Talents Program" medical and health personnel project, National key Research and Development Program of China
  • Hubei Provincial Key Technology Foundation of China
  • The Key Research and Development Plan of Hubei Province

Zitieren

APA

Ai, S., Peng, W., Hou, R., Zhang, H., Grimm, R., Yuan, Z., & Liu, Y. (2025). Effects of simultaneous multislice acceleration on the stability of radiomics features in parametric maps of IVIM and DKI in uterine cervical cancer. Journal of Applied Clinical Medical Physics. https://doi.org/10.1002/acm2.70063

Vancouver

Ai S, Peng W, Hou R, Zhang H, Grimm R, Yuan Z, et al. Effects of simultaneous multislice acceleration on the stability of radiomics features in parametric maps of IVIM and DKI in uterine cervical cancer. Journal of Applied Clinical Medical Physics. 2025. doi:10.1002/acm2.70063

BibTeX
@article{Ai2025,
  author = {Ai, Shuangquan and Peng, Wei and Hou, Rong and Zhang, Huiting and Grimm, Robert and Yuan, Zilong and Liu, Yulin},
  title = {Effects of simultaneous multislice acceleration on the stability of radiomics features in parametric maps of IVIM and DKI in uterine cervical cancer},
  journal = {Journal of Applied Clinical Medical Physics},
  year = {2025},
  doi = {10.1002/acm2.70063}
}
Kostenlos starten →