Assessing proton plans with three different beam delivery systems versus photon plans for head and neck tumors
Journal of Applied Clinical Medical Physics · 2025
DOI: 10.1002/acm2.70013 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Journal of Applied Clinical Medical Physics, 2025. Verfasst von Tara Gray und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, Cleveland Clinic Foundation, Cleveland, Ohio, USA. Hauptthemen laut MEDLINE: Radiotherapy Planning, Computer-Assisted, Proton Therapy, Photons, Organs at Risk. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 50 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Purpose
To compare plan quality among photon volumetric modulated arc therapy (VMAT) and intensity‐modulated proton therapy (IMPT) with robustness using three different proton beam delivery systems with various spot size (σ) ranges: cyclotron‐generated proton beams (CPBs) (σ: 2.7–7.0 mm), linear accelerator proton beams (LPBs) (σ: 2.9–5.5 mm), and linear accelerator proton mini beams (LPMBs) (σ: 0.8–3.9 mm) for the treatment of head and neck (HN) cancer with bilateral neck irradiation.
Methods
Ten patients treated for oropharynx cancer with bilateral neck irradiation were planned using CPBs, LPBs, LPMBs, and VMAT. The homogeneity index (HI), mean body dose, and defined volumetric doses for selected critical organs‐at‐risk (OARs) were compared. Set‐up uncertainties of ±3 mm and ± 3.5% range uncertainties were included in robust evaluation using V 95%Rx > 95% (Volume that covers 95% of the target volume at 95% of the prescription (Rx) dose) to high dose and low dose CTV volumes (CTV_70 Gy and CTV_56 Gy). VMAT and proton plans were compared in terms of OAR doses and mean body dose only. Homogeneity Indices were compared among IMPT plans in addition to OAR doses. The Wilcoxon signed‐rank test was used to evaluate statistical differences between evaluation metrics for VMAT plans and all proton plan types.
Results
OAR dose metrics were improved by 2% to 30% from CPB plans to LPB or LPMB plans. Compared to photon VMAT plans, all OAR doses except for mandible dose metrics were improved by 2% to 53% for all proton plans. The mean body dose was also improved by 7.5% from CPB to LPB and by 10.8% from CPB to LPMB. In addition, the mean body dose was also improved by 44% from VMAT to CPB, by 48% from VMAT to LPB, and by 50% from VMAT to LPMB plans. Compared to CPB plans, HI was significantly better ( p < 0.05) for the LPB and LPMB plans. HI also improved considerably from VMAT to CPB, LPB, and LPMB. For both CTV_70 Gy and CTV_56 Gy, average robust evaluation across all worst‐case scenarios was slightly better for CPB plans, with an average of V 95%Rx of the CTV_70 Gy of 97.6% ± 1.22%, followed by 97.2% ± 1.31% and 97.2% ± 1.35% for LPB and LPMB plans, respectively. Robustness for CTV_56 Gy showed comparable robustness across all proton plan types, with an average V 95%Rx of 97.4% ± 0.87% for CPB, 97.4% ± 1.21%, and 97.5% ± 1.08% for CPB, LPB, and LPMB plans, respectively.
Conclusion
With decreased spot size, the LPB and LPMB are excellent alternatives to VMAT and CPB therapy and can significantly reduce the dose to normal tissue.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiation Oncology, Cleveland Clinic Foundation, Cleveland, Ohio, USA.
- Department of Radiation Oncology, University of Kansas Medical Center, Kansas City, Kansas, USA.
- Applications of Detectors and Accelerators to Medicine (ADAM), Advanced Oncotherapy (AVO) plc, London, UK.
ORCID-Profile: Tara Gray
Zitieren
APA
Gray, T., Liu, C. W., Ahmed, S., Kolano, A. M., Donaghue, J., Koyfman, S., Woody, N., Campbell, S. R., Farr, J. B., & Xia, P. (2025). Assessing proton plans with three different beam delivery systems versus photon plans for head and neck tumors. Journal of Applied Clinical Medical Physics. https://doi.org/10.1002/acm2.70013
Vancouver
Gray T, Liu CW, Ahmed S, Kolano AM, Donaghue J, Koyfman S, et al. Assessing proton plans with three different beam delivery systems versus photon plans for head and neck tumors. Journal of Applied Clinical Medical Physics. 2025. doi:10.1002/acm2.70013
BibTeX
@article{Gray2025,
author = {Gray, Tara and Liu, Chieh-Wen and Ahmed, Saeed and Kolano, Anna Maria and Donaghue, Jeremy and Koyfman, Shlomo and Woody, Neil and Campbell, Shauna R and Farr, Jonathan B and Xia, Ping},
title = {Assessing proton plans with three different beam delivery systems versus photon plans for head and neck tumors},
journal = {Journal of Applied Clinical Medical Physics},
year = {2025},
doi = {10.1002/acm2.70013}
}
EUVIMED