Evaluation and comparison of synthetic computed tomography algorithms with 3T MRI for prostate radiotherapy: AI‐based versus bulk density method
Journal of Applied Clinical Medical Physics · 2025
DOI: 10.1002/acm2.14581 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Journal of Applied Clinical Medical Physics, 2025. Verfasst von Sakari S Karhula und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Oncology and Radiotherapy, Oulu University Hospital, Oulu, Finland. Hauptthemen laut MEDLINE: Prostatic Neoplasms, Radiotherapy Planning, Computer-Assisted, Algorithms, Tomography, X-Ray Computed. Die Arbeit nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Purpose
Synthetic computed tomography (sCT)‐algorithms, which generate computed tomography images from magnetic resonance imaging data, are becoming part of the clinical radiotherapy workflow. The aim of this retrospective study was to evaluate and compare commercial bulk‐density‐method (BM)‐based and AI (artificial intelligence)‐based‐algorithms using 3T magnetic resonance imaging (MRI) with patient data as part of the local clinical commissioning process.
Methods
44 prostate radiotherapy patients were subjected to MRI and treatment planning CT (TPCT) scans. From the MRI images, sCT images with two different sCT algorithms were generated. The sCT images were evaluated by visual inspection of artifacts. Both sCT methods were compared to TPCT, with Dice similarity score(DSC) of bone and body contours, DVH parameters for CTV, bladder and rectum, and gamma‐analysis. Accuracy for treatment alignment using sCT images was also tested. Various limits were used to define whether the differences between sCT methods to TPCT were clinically relevant (DVH parameters
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Oncology and Radiotherapy, Oulu University Hospital, Oulu, Finland.
- Research unit of Health Sciences and Technology, Oulu University, Oulu, Finland.
ORCID-Profile: Sakari S Karhula
Zitieren
APA
Karhula, S. S., Karppinen, P., Hietala, H., & Nikkinen, J. (2025). Evaluation and comparison of synthetic computed tomography algorithms with 3T MRI for prostate radiotherapy: AI‐based versus bulk density method. Journal of Applied Clinical Medical Physics. https://doi.org/10.1002/acm2.14581
Vancouver
Karhula SS, Karppinen P, Hietala H, Nikkinen J. Evaluation and comparison of synthetic computed tomography algorithms with 3T MRI for prostate radiotherapy: AI‐based versus bulk density method. Journal of Applied Clinical Medical Physics. 2025. doi:10.1002/acm2.14581
BibTeX
@article{Karhula2025,
author = {Karhula, Sakari S and Karppinen, Piia and Hietala, Henna and Nikkinen, Juha},
title = {Evaluation and comparison of synthetic computed tomography algorithms with 3T MRI for prostate radiotherapy: AI‐based versus bulk density method},
journal = {Journal of Applied Clinical Medical Physics},
year = {2025},
doi = {10.1002/acm2.14581}
}
EUVIMED