Pelvic target volume inter-fractional motion during radiotherapy for cervical cancer with daily iterative cone beam computed tomography
Radiation Oncology · 2024
DOI: 10.1186/s13014-024-02438-1 ↗Kurz gefasst
Fachartikel in der Zeitschrift Radiation Oncology, 2024. Verfasst von Zheng Zeng und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, 100730, …. Hauptthemen laut MEDLINE: Uterine Cervical Neoplasms, Radiotherapy, Image-Guided, Radiotherapy, Intensity-Modulated. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National High Level Hospital Clinical Research Funding, National Key R&D Program of China, Ministry of Science and Technology of the People's Republic of China.
Abstract (Originalsprache)
Background
Tumor regression and organ movements indicate that a large margin is used to ensure target volume coverage during radiotherapy. This study aimed to quantify inter-fractional movements of the uterus and cervix in patients with cervical cancer undergoing radiotherapy and to evaluate the clinical target volume (CTV) coverage.
Methods
This study analyzed 303 iterative cone beam computed tomography (iCBCT) scans from 15 cervical cancer patients undergoing external beam radiotherapy. CTVs of the uterus (CTV-U) and cervix (CTV-C) contours were delineated based on each iCBCT image. CTV-U encompassed the uterus, while CTV-C included the cervix, vagina, and adjacent parametrial regions. Compared with the planning CTV, the movement of CTV-U and CTV-C in the anterior-posterior, superior-inferior, and lateral directions between iCBCT scans was measured. Uniform expansions were applied to the planning CTV to assess target coverage.
Results
The motion (mean ± standard deviation) in the CTV-U position was 8.3 ± 4.1 mm in the left, 9.8 ± 4.4 mm in the right, 12.6 ± 4.0 mm in the anterior, 8.8 ± 5.1 mm in the posterior, 5.7 ± 5.4 mm in the superior, and 3.0 ± 3.2 mm in the inferior direction. The mean CTV-C displacement was 7.3 ± 3.2 mm in the left, 8.6 ± 3.8 mm in the right, 9.0 ± 6.1 mm in the anterior, 8.4 ± 3.6 mm in the posterior, 5.0 ± 5.0 mm in the superior, and 3.0 ± 2.5 mm in the inferior direction. Compared with the other tumor (T) stages, CTV-U and CTV-C motion in stage T1 was larger. A uniform CTV planning treatment volume margin of 15 mm failed to encompass the CTV-U and CTV-C in 11.1% and 2.2% of all fractions, respectively. The mean volume change of CTV-U and CTV-C were 150% and 51%, respectively, compared with the planning CTV.
Conclusions
Movements of the uterine corpus are larger than those of the cervix. The likelihood of missing the CTV is significantly increased due to inter-fractional motion when utilizing traditional planning margins. Early T stage may require larger margins. Personal radiotherapy margining is needed to improve treatment accuracy.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiation Oncology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, 100730, Beijing, China.
- Department of Radiation Oncology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, 100730, Beijing, China. yanjunfang@pumch.cn.
- Department of Radiation Oncology, State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College Hospital, Chinese Academy of Medical Science and Peking Union Medical College, 100730, Beijing, Ch…
Förderung
- National High Level Hospital Clinical Research Funding
- National Key R&D Program of China, Ministry of Science and Technology of the People's Republic of China
Zitieren
APA
Zeng, Z., Zhu, J., Wang, Z., Wang, G., Yan, J., & Zhang, F. (2024). Pelvic target volume inter-fractional motion during radiotherapy for cervical cancer with daily iterative cone beam computed tomography. Radiation Oncology. https://doi.org/10.1186/s13014-024-02438-1
Vancouver
Zeng Z, Zhu J, Wang Z, Wang G, Yan J, Zhang F. Pelvic target volume inter-fractional motion during radiotherapy for cervical cancer with daily iterative cone beam computed tomography. Radiation Oncology. 2024. doi:10.1186/s13014-024-02438-1
BibTeX
@article{Zeng2024,
author = {Zeng, Zheng and Zhu, Jiawei and Wang, Zhiqun and Wang, Guangyu and Yan, Junfang and Zhang, Fuquan},
title = {Pelvic target volume inter-fractional motion during radiotherapy for cervical cancer with daily iterative cone beam computed tomography},
journal = {Radiation Oncology},
year = {2024},
doi = {10.1186/s13014-024-02438-1}
}
EUVIMED