EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Improvement of treatment plan quality with modified fixed field volumetric modulated arc therapy in cervical cancer

Sirawat Jindakan, Ekkasit Tharavichitkul, Anirut Watcharawipha iD, Wannapha Nobnop iD

Journal of Applied Clinical Medical Physics · 2024

DOI: 10.1002/acm2.14479 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Applied Clinical Medical Physics, 2024. Verfasst von Sirawat Jindakan und 3 weiteren Autor:innen. Beteiligte Einrichtung: Medical Physics Program, Department of Radiology, Faculty of Medicine, Chiang Mai University, Chiang Mai, Thailand. Hauptthemen laut MEDLINE: Radiotherapy, Intensity-Modulated, Radiotherapy Planning, Computer-Assisted, Uterine Cervical Neoplasms, Organs at Risk. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 49 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

This study aims to introduce modified fixed field volumetric modulated arc therapy (MF‐VMAT) which manually opened the field size by fixing the jaws and comparing it to the typical planning technique, auto field volumetric modulated arc therapy (AF‐VMAT) in cervical cancer treatment planning. Methods and materials Previously treated twenty‐eight cervical cancer plans were retrospectively randomly selected and replanned in this study using two different planning techniques: AF‐VMAT and MF‐VMAT, resulting in a total of fifty‐six treatment plans. In this study, we compared both planning techniques in three parts: (1) Organ at Risk (OARs) and whole‐body dose, (2) Treatment plan efficiency, and (3) Treatment plan accuracy.

Results

For OARs dose, bowel bag ( p ‐value = 0.001), rectum ( p ‐value = 0.002), and left femoral head ( p ‐value = 0.001) and whole‐body ( p ‐value = 0.000) received a statistically significant dose reduction when using the MF‐VMAT plan. Regarding plan efficiency, MF‐VMAT exhibited a statistically significant increase in both number of monitor units (MUs) and control points ( p ‐values = 0.000), while beam‐on time, maximum leaf travel, average maximum leaf travel, and maximum leaf travel per gantry rotation were statistically significant decreased ( p ‐values = 0.000). In terms of plan accuracy, the average gamma passing rate was higher in the MF‐VMAT plan for both absolute dose (AD) ( p ‐value = 0.001, 0.004) and relative dose (RD) ( p ‐value = 0.000, 0.000) for 3%/3 and 3%/2 mm gamma criteria, respectively.

Conclusion

The MF‐VMAT planning technique significantly reduces OAR doses and decreases the spread of low doses to normal tissues in cervical cancer patients. Additionally, this planning approach demonstrates efficient plans with lower beam‐on time and reduced maximum leaf travel. Furthermore, it indicates higher plan accuracy through an increase in the average gamma passing rate compared to the AF‐VMAT plan. Consequently, MF‐VMAT offers an effective treatment planning technique for cervical cancer patients.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Radiotherapy, Intensity-ModulatedRadiotherapy Planning, Computer-AssistedUterine Cervical NeoplasmsOrgans at RiskRadiotherapy DosageHumansFemaleRetrospective StudiesPrognosisQuality ImprovementQuality Assurance, Health Care

Stichwörter der Autor:innen

auto fieldcervical cancermodified fixed fieldvolumetric modulated arc therapy

Autor:innen und Institutionen

  • Medical Physics Program, Department of Radiology, Faculty of Medicine, Chiang Mai University, Chiang Mai, Thailand.
  • Department of Radiology, Faculty of Medicine, The Division of Radiation Oncology, Chiang Mai University, Chiang Mai, Thailand.

ORCID-Profile: Anirut Watcharawipha, Wannapha Nobnop

Zitieren

APA

Jindakan, S., Tharavichitkul, E., Watcharawipha, A., & Nobnop, W. (2024). Improvement of treatment plan quality with modified fixed field volumetric modulated arc therapy in cervical cancer. Journal of Applied Clinical Medical Physics. https://doi.org/10.1002/acm2.14479

Vancouver

Jindakan S, Tharavichitkul E, Watcharawipha A, Nobnop W. Improvement of treatment plan quality with modified fixed field volumetric modulated arc therapy in cervical cancer. Journal of Applied Clinical Medical Physics. 2024. doi:10.1002/acm2.14479

BibTeX
@article{Jindakan2024,
  author = {Jindakan, Sirawat and Tharavichitkul, Ekkasit and Watcharawipha, Anirut and Nobnop, Wannapha},
  title = {Improvement of treatment plan quality with modified fixed field volumetric modulated arc therapy in cervical cancer},
  journal = {Journal of Applied Clinical Medical Physics},
  year = {2024},
  doi = {10.1002/acm2.14479}
}
Kostenlos starten →