Rectal deformation management with IGRT in prostate radiotherapy: Can it be managed with rigid alignment alone?
Journal of Applied Clinical Medical Physics · 2024
DOI: 10.1002/acm2.14241 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Applied Clinical Medical Physics, 2024. Verfasst von Mitchell Polizzi und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, Virginia Commonwealth University, Richmond, Virginia, USA. Hauptthemen laut MEDLINE: Radiotherapy, Image-Guided, Prostatic Neoplasms, Radiotherapy, Intensity-Modulated. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 52 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Purpose
It is challenging to achieve appropriate target coverage of the prostate with Image Guided Radiation Therapy (IGRT) while simultaneously constraining rectal doses within planned values when there is significant variability in rectal filling and shape. We investigated if rectum planning goals can be fulfilled using rigid CBCT‐based on‐board alignment to account for interfraction rectal deformations.
Methods
Delivered rectal doses corresponding to prostate alignment (“PR”) and anterior rectum alignment (“AR”) for 239 daily treatments from 13 patients are reported. Rectal doses were estimated by rigidly mapping the planned dose on the daily CT derived from the daily CBCT according to respective alignment shifts. Rectum V95% (rV95%) was used for analyses.
Results
Compared to “PR”, “AR” alignment increased rV95% for an average of 34.4% across all patients. rV95% (cc) averaged over all fractions was significant from planning values for 10/13 patients for “PR” and for 9/13 for “AR”. 3/13 patients had reproducible anatomy. Of patients with non‐reproducible anatomy, three had dosimetrically more favorable, while seven had less favorable anatomies. Most shift differences (82.3%) between the “PR” and “AR” alignments larger than 2 mm resulted in rV95% changes larger than 2 cc. Most shift differences (82.2%) of 2 mm or less between the “PR” and “AR” alignments resulted in rV95% changes less than 2 cc. The average percentage of fractions among patients in which anterior or posterior shifts for “AR” and “PR” alignment was larger than the PTV margins was 9.1% (0.0%–37.5%) and 1.3% (0%–10%).
Conclusion
Rectal deformation and subsequent inconsistent interfraction separation between prostate and rectal wall translate into anatomical changes that cannot always be mitigated with rigid alignment. If systematic differences exist due to a non‐reproducible planning anatomy, attempts to restore the planned rectal doses through anterior rectum alignment produce rather small improvements and may result in unacceptable target underdosage.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiation Oncology, Virginia Commonwealth University, Richmond, Virginia, USA.
Zitieren
APA
Polizzi, M., Weiss, E., Jan, N., Ricco, A., Kim, S., Urdaneta, A., & Rosu-Bubulac, M. (2024). Rectal deformation management with IGRT in prostate radiotherapy: Can it be managed with rigid alignment alone?. Journal of Applied Clinical Medical Physics. https://doi.org/10.1002/acm2.14241
Vancouver
Polizzi M, Weiss E, Jan N, Ricco A, Kim S, Urdaneta A, et al. Rectal deformation management with IGRT in prostate radiotherapy: Can it be managed with rigid alignment alone?. Journal of Applied Clinical Medical Physics. 2024. doi:10.1002/acm2.14241
BibTeX
@article{Polizzi2024,
author = {Polizzi, Mitchell and Weiss, Elisabeth and Jan, Nuzhat and Ricco, Anthony and Kim, Siyong and Urdaneta, Alfredo and Rosu-Bubulac, Mihaela},
title = {Rectal deformation management with IGRT in prostate radiotherapy: Can it be managed with rigid alignment alone?},
journal = {Journal of Applied Clinical Medical Physics},
year = {2024},
doi = {10.1002/acm2.14241}
}
EUVIMED