EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

The influence of patient positioning and immobilization equipment on MR image quality and image registration in radiation therapy

Atefeh Rostami iD, Mostafa Robatjazi iD, Seyed Alireza Javadinia iD, Nematullah Shomoossi iD, Ramin Shahraini iD

Journal of Applied Clinical Medical Physics · 2024

DOI: 10.1002/acm2.14162 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Applied Clinical Medical Physics, 2024. Verfasst von Atefeh Rostami und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medical Physics and Radiological Sciences, Sabzevar University of Medical Sciences, Sabzevar, Iran. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Radiotherapy, Image-Guided. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 19 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

MRI is preferred for brain tumor assessment, while CT is used for radiotherapy simulation. This study evaluated immobilization equipment's impact on CT‐MRI registration accuracy and MR image quality in RT setup.

Methods

We included CT and MR images from 11 patients with high‐grade glioma, all of whom were immobilized with a thermoplastic mask and headrest. T1‐ and T2‐weighted MR images were acquired using an MR head coil in a diagnostic setup (DS) and a body matrix coil in RT setup. To assess MR image quality, signal‐to‐noise ratio (SNR) and contrast‐to‐noise ratio (CNR) were considered in some dedicated regions of interest. We also evaluated the impact of immobilization equipment on CT‐MRI rigid registration using line profile and external contour methods.

Results

The CNR and SNR reduction was in the RT setup of imaging. This was more evident in T1‐weighted images than in T2‐weighted ones. The SNR decreased by 14.91% and 12.09%, while CNR decreased by 25.12% and 20.15% in T1‐ and T2‐weighted images, respectively. The immobilization equipment in the RT setup decreased the mean error in rigid registration by 1.02 mm. The external contour method yielded Dice similarity coefficients (DSC) of 0.84 and 0.92 for CT‐DS MRI and CT‐RT MRI registration, respectively.

Conclusion

The image quality reduction in the RT setup was due to the imaged region's anatomy and its position relative to the applied coil. Furthermore, optimizing the pulse sequence is crucial for MR imaging in RT applications. Although the use of immobilization equipment may decrease the image quality in the RT setup, it does not affect organ delineation, and the image quality is still satisfactory for this purpose. Also, the use of immobilization equipment in the RT setup has increased registration accuracy.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Resonance ImagingRadiotherapy, Image-GuidedHumansPatient PositioningPhantoms, ImagingRadiotherapy Planning, Computer-Assisted

Stichwörter der Autor:innen

brain tumormagnetic resonance imagingthree dimensional (3D) conformal radiation therapy

Autor:innen und Institutionen

  • Department of Medical Physics and Radiological Sciences, Sabzevar University of Medical Sciences, Sabzevar, Iran.
  • Non-Communicable Diseases Research Center, Sabzevar University of Medical Sciences, Sabzevar, Iran.
  • School of Medicine, Sabzevar University of Medical Sciences, Sabzevar, Iran.
  • Department of Radiology, School of Medicine, Sabzevar University of Medical Sciences, Sabzevar, Iran.

ORCID-Profile: Atefeh Rostami, Mostafa Robatjazi, Seyed Alireza Javadinia, Nematullah Shomoossi, Ramin Shahraini

Zitieren

APA

Rostami, A., Robatjazi, M., Javadinia, S. A., Shomoossi, N., & Shahraini, R. (2024). The influence of patient positioning and immobilization equipment on MR image quality and image registration in radiation therapy. Journal of Applied Clinical Medical Physics. https://doi.org/10.1002/acm2.14162

Vancouver

Rostami A, Robatjazi M, Javadinia SA, Shomoossi N, Shahraini R. The influence of patient positioning and immobilization equipment on MR image quality and image registration in radiation therapy. Journal of Applied Clinical Medical Physics. 2024. doi:10.1002/acm2.14162

BibTeX
@article{Rostami2024,
  author = {Rostami, Atefeh and Robatjazi, Mostafa and Javadinia, Seyed Alireza and Shomoossi, Nematullah and Shahraini, Ramin},
  title = {The influence of patient positioning and immobilization equipment on MR image quality and image registration in radiation therapy},
  journal = {Journal of Applied Clinical Medical Physics},
  year = {2024},
  doi = {10.1002/acm2.14162}
}
Kostenlos starten →