EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Comparing brass mesh to tissue equivalent bolus materials for volumetric modulated arc therapy chest wall irradiation

Timothy D Keiper, Kelly Kisling, Patricia Hua, Ryan P Manger

Journal of Applied Clinical Medical Physics · 2023

DOI: 10.1002/acm2.14054 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Applied Clinical Medical Physics, 2023. Verfasst von Timothy D Keiper und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Medicine and Applied Sciences, Moores Cancer Center, University of California San Diego, La Jolla, California, USA. Hauptthemen laut MEDLINE: Radiotherapy, Intensity-Modulated, Thoracic Wall, Breast Neoplasms. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 15 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To compare the superficial dose when using brass mesh bolus (BMB), no bolus, or 3 mm tissue‐equivalent bolus with a pseudo‐flash volumetric modulated arc therapy (VMAT) breast treatment planning technique.

Methods

Two different beam arrangements for right‐sided irradiation and one beam arrangement for bilateral irradiation were planned on an inhomogeneous thorax phantom in accordance with our clinical practice for VMAT postmastectomy radiotherapy (PMRT). Plans were optimized using pseudo‐flash and representative critical organ optimization structures were used to shape the dose. Plans were delivered without bolus, with 3 mm tissue‐equivalent bolus (TEB), or with one‐layer BMB. Optically stimulated luminescence dosimeter (OSLD) and radiochromic film measurements were taken and analyzed to determine the superficial dose in each case and the relative enhancement from the no bolus delivery.

Results

Superficial dose measured with OSLDs was found to be 76.4 ± 4.5%, 103.0 ± 6.1%, and 98.1 ± 5.8% of prescription for no physical bolus (NB), TEB, and BMB, respectively. Superficial dose was observed to increase from lateral to medial points when measured with film. However, the relative increase in superficial dose from NB was consistent across the profile with an increase of 43 ± 2.1% and 34 ± 3.3% of prescription for TEB and BMB, respectively. The results are in good agreement with expectations from the literature and the experience with tangential radiotherapy.

Conclusion

Three millimeter TEB and one‐layer BMB were shown to provide similar enhancement to the superficial dose compared to delivery without bolus. BMB, which does not significantly affect dose at depth and is more conformal to the patient surface, is an acceptable alternative to 3 mm TEB for chest wall PMRT patients treated with pseudo‐flash PMRT.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Radiotherapy, Intensity-ModulatedThoracic WallBreast NeoplasmsHumansFemaleRadiotherapy Planning, Computer-AssistedRadiotherapy DosageMastectomyCopperZinc

Stichwörter der Autor:innen

VMAT breastbrass bolusbrass mesh

Substanzen

brassCopperZinc

Autor:innen und Institutionen

  • Department of Radiation Medicine and Applied Sciences, Moores Cancer Center, University of California San Diego, La Jolla, California, USA.
  • California Protons Cancer Therapy Center, San Diego, California, USA.

Zitieren

APA

Keiper, T. D., Kisling, K., Hua, P., & Manger, R. P. (2023). Comparing brass mesh to tissue equivalent bolus materials for volumetric modulated arc therapy chest wall irradiation. Journal of Applied Clinical Medical Physics. https://doi.org/10.1002/acm2.14054

Vancouver

Keiper TD, Kisling K, Hua P, Manger RP. Comparing brass mesh to tissue equivalent bolus materials for volumetric modulated arc therapy chest wall irradiation. Journal of Applied Clinical Medical Physics. 2023. doi:10.1002/acm2.14054

BibTeX
@article{Keiper2023,
  author = {Keiper, Timothy D and Kisling, Kelly and Hua, Patricia and Manger, Ryan P},
  title = {Comparing brass mesh to tissue equivalent bolus materials for volumetric modulated arc therapy chest wall irradiation},
  journal = {Journal of Applied Clinical Medical Physics},
  year = {2023},
  doi = {10.1002/acm2.14054}
}
Kostenlos starten →