A virtual audit system for intensity‐modulated radiation therapy credentialing in Japan Clinical Oncology Group clinical trials: A pilot study

Mitsuhiro Nakamura, Dejun Zhou iD, Toshiyuki Minemura, Satoshi Kito, Hiroyuki Okamoto iD, Naoki Tohyama, Masahiko Kurooka, Yu Kumazaki, Masayori Ishikawa iD, Catharine H Clark, Elizabeth Miles, Joerg Lehmann und 5 weitere

Journal of Applied Clinical Medical Physics · 2023-06 · 24 (6)

DOI: 10.1002/acm2.14040 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Applied Clinical Medical Physics, online erschienen am 16.05.2023. Verfasst von Mitsuhiro Nakamura und 16 weiteren Autor:innen. Beteiligte Einrichtung: Department of Advanced Medical Physics, Graduate School of Medicine, Kyoto University, Kyoto, Japan. Hauptthemen laut MEDLINE: Radiotherapy Planning, Computer-Assisted, Radiotherapy, Intensity-Modulated. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Cancer Center Research and Development Fund, Grant-in-Aid for Fostering Joint International Research (B).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

The Medical Physics Working Group of the Radiation Therapy Study Group at the Japan Clinical Oncology Group is currently developing a virtual audit system for intensity‐modulated radiation therapy dosimetry credentialing. The target dosimeters include films and array detectors, such as ArcCHECK (Sun Nuclear Corporation, Melbourne, Florida, USA) and Delta4 (ScandiDos, Uppsala, Sweden). This pilot study investigated the feasibility of our virtual audit system using previously acquired data.

Methods

We analyzed 46 films (32 and 14 in the axial and coronal planes, respectively) from 29 institutions. Global gamma analysis between measured and planned dose distributions used the following settings: 3%/3 mm criteria (the dose denominator was 2 Gy), 30% threshold dose, no scaling of the datasets, and 90% tolerance level. In addition, 21 datasets from nine institutions were obtained for array evaluation. Five institutions used ArcCHECK, while the others used Delta4. Global gamma analysis was performed with 3%/2 mm criteria (the dose denominator was the maximum calculated dose), 10% threshold dose, and 95% tolerance level. The film calibration and gamma analysis were conducted with in‐house software developed using Python (version 3.9.2).

Results

The means ± standard deviations of the gamma passing rates were 99.4 ± 1.5% (range, 92.8%–100%) and 99.2 ± 1.0% (range, 97.0%–100%) in the film and array evaluations, respectively.

Conclusion

This pilot study demonstrated the feasibility of virtual audits. The proposed virtual audit system will contribute to more efficient, cheaper, and more rapid trial credentialing than on‐site and postal audits; however, the limitations should be considered when operating our virtual audit system.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Radiotherapy Planning, Computer-AssistedRadiotherapy, Intensity-ModulatedHumansPilot ProjectsJapanCredentialingRadiometryRadiotherapy DosageMedical OncologyPhantoms, Imaging

Stichwörter der Autor:innen

IMRT dosimetry credentialingJCOGgamma analysisprospective trialsvirtual audit

Autor:innen und Institutionen

  • Department of Advanced Medical Physics, Graduate School of Medicine, Kyoto University, Kyoto, Japan.
  • Institute for Cancer Control, National Cancer Center, Tokyo, Japan.
  • Department of Radiation Oncology, Tokyo Metropolitan Cancer and Infectious Disease Center Komagome Hospital, Tokyo, Japan.
  • Radiation Safety and Quality Assurance Division, National Cancer Center Hospital, Tokyo, Japan.
  • Division of Medical Physics, Tokyo Bay Makuhari Clinic for Advanced Imaging, Cancer Screening, and High-Precision Radiotherapy, Chiba, Japan.
  • Department of Radiation Therapy, Tokyo Medical University Hospital, Tokyo, Japan.

ORCID-Profile: Dejun Zhou, Hiroyuki Okamoto, Masayori Ishikawa, Takashi Mizowaki

Förderung

  • National Cancer Center Research and Development Fund
  • Grant-in-Aid for Fostering Joint International Research (B)

Zitieren

APA

Nakamura, M., Zhou, D., Minemura, T., Kito, S., Okamoto, H., Tohyama, N., Kurooka, M., Kumazaki, Y., Ishikawa, M., Clark, C. H., Miles, E., Lehmann, J., Andratschke, N., Kry, S., Ishikura, S., Mizowaki, T., & Nishio, T. (2023). A virtual audit system for intensity‐modulated radiation therapy credentialing in Japan Clinical Oncology Group clinical trials: A pilot study. Journal of Applied Clinical Medical Physics, 24(6). https://doi.org/10.1002/acm2.14040

Vancouver

Nakamura M, Zhou D, Minemura T, Kito S, Okamoto H, Tohyama N, et al. A virtual audit system for intensity‐modulated radiation therapy credentialing in Japan Clinical Oncology Group clinical trials: A pilot study. Journal of Applied Clinical Medical Physics. 2023;24(6). doi:10.1002/acm2.14040

BibTeX
@article{Nakamura2023,
  author = {Nakamura, Mitsuhiro and Zhou, Dejun and Minemura, Toshiyuki and Kito, Satoshi and Okamoto, Hiroyuki and Tohyama, Naoki and Kurooka, Masahiko and Kumazaki, Yu and Ishikawa, Masayori and Clark, Catharine H and Miles, Elizabeth and Lehmann, Joerg and Andratschke, Nicolaus and Kry, Stephen and Ishikura, Satoshi and Mizowaki, Takashi and Nishio, Teiji},
  title = {A virtual audit system for intensity‐modulated radiation therapy credentialing in Japan Clinical Oncology Group clinical trials: A pilot study},
  journal = {Journal of Applied Clinical Medical Physics},
  year = {2023},
  volume = {24},
  number = {6},
  doi = {10.1002/acm2.14040}
}
Kostenlos starten →