EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Preliminary dosimetric comparison between fixed and rotating source stereotactic radiosurgery systems

Emily Draeger, Zhe Jay Chen, James E Hansen, Veronica Chiang, Christopher J Tien

Journal of Applied Clinical Medical Physics · 2023

DOI: 10.1002/acm2.13907 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Applied Clinical Medical Physics, 2023. Verfasst von Emily Draeger und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Therapeutic Radiology, Yale University School of Medicine, New Haven, Connecticut, USA. Hauptthemen laut MEDLINE: Radiosurgery, Brain Neoplasms, Pituitary Neoplasms. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 18 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NCATS NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

The Akesis Galaxy RTi (AK) is a novel rotational 60 Co‐based cranial stereotactic radiosurgery (SRS) system. While similar systems have been compared against the fixed‐source Leksell Gamma Knife (GK) system using stylized phantoms, dosimetric plan quality with realistic anatomy has yet to be characterized for this or any other rotating system versus GK. This study aims to benchmark AK dosimetric performance against GK by retrospectively replanning previously‐treated GK patients at our institution.

Methods

Thirteen patients, previously treated on a GK Icon, were re‐planned on the AK treatment planning system using the same prescription doses and isodoses as the original GK plans. The cohort includes patients treated for brain metastases, schwannomas, pituitary adenomas, trigeminal neuralgias, and arteriovenous malformations. Plans are evaluated with target coverage metrics (D min , D mean , D 95% , V 150% ) and dose conformality indices: Radiation Therapy Oncology Group conformity index (CI), selectivity, Paddick CI (PCI), gradient index (GI).

Results

AK plans use fewer shots and larger collimation compared to GK plans, resulting in statistically significant reductions in treatment time ( p = 0.047) by as much as 88.4 minutes while maintaining comparable target V 100% . For most metastatic cases, GK produces higher D min (16.0–25.9 vs. 12.5–24.3 Gy, p = 0.008) while AK produces higher V 150% (0.03–14.92 vs. 0.02–11.59 cc, p = 0.028). For non‐metastatic cases, GK provides superior CI ( p = 0.025) and GI ( p = 0.044). No statistically significant differences were found in the remaining metrics.

Conclusion

This cohort demonstrates that the AK system is able to achieve largely comparable dosimetric results to GK, typically with shorter treatment times. Further investigation with a larger cohort is underway.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

RadiosurgeryBrain NeoplasmsPituitary NeoplasmsHumansRetrospective StudiesRadiometryRadiotherapy Planning, Computer-AssistedRadiotherapy Dosage

Stichwörter der Autor:innen

Gamma Kniferotating source gamma systemstereotactic radiosurgery

Autor:innen und Institutionen

  • Department of Therapeutic Radiology, Yale University School of Medicine, New Haven, Connecticut, USA.
  • Department of Neurosurgery, Yale University School of Medicine, New Haven, Connecticut, USA.

Förderung

  • NCATS NIH HHS

Zitieren

APA

Draeger, E., Chen, Z. J., Hansen, J. E., Chiang, V., & Tien, C. J. (2023). Preliminary dosimetric comparison between fixed and rotating source stereotactic radiosurgery systems. Journal of Applied Clinical Medical Physics. https://doi.org/10.1002/acm2.13907

Vancouver

Draeger E, Chen ZJ, Hansen JE, Chiang V, Tien CJ. Preliminary dosimetric comparison between fixed and rotating source stereotactic radiosurgery systems. Journal of Applied Clinical Medical Physics. 2023. doi:10.1002/acm2.13907

BibTeX
@article{Draeger2023,
  author = {Draeger, Emily and Chen, Zhe Jay and Hansen, James E and Chiang, Veronica and Tien, Christopher J},
  title = {Preliminary dosimetric comparison between fixed and rotating source stereotactic radiosurgery systems},
  journal = {Journal of Applied Clinical Medical Physics},
  year = {2023},
  doi = {10.1002/acm2.13907}
}
Kostenlos starten →